{"product_id":"330762-04-80-80-75-75-94-02-02-bently-nevada-3300-xl-dual-triaxial-feedthrough","title":"330762-04-80-80-75-75-94-02-02 Bently Nevada 3300 XL Dual Triaxial Feedthrough","description":"\u003ch2\u003eBently Nevada 330762 Dual Triaxial High-Pressure Feedthrough\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 330762-04-80-80-75-75-94-02-02\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e 3300 XL \/ 3300 Proximity Measurement Systems\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Dual Triaxial High-Pressure Feedthrough\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e USA\u003c\/p\u003e\n\u003cp\u003eThe Bently Nevada 330762-04-80-80-75-75-94-02-02 is a dual triaxial high-pressure feedthrough designed to route two proximity-probe cable connections through a pressurized machine casing. It provides a pressure boundary between the machine interior and the external cable connection area while supporting proximity measurement systems used for rotating machinery monitoring.\u003c\/p\u003e\n\u003cp\u003eThis configuration features armor at both ends, 8.0 m Dimension 1 and Dimension 2 lengths, 7.5 m Dimension 3 and Dimension 4 lengths, fluorocarbon O-rings, and male miniature coaxial connectors at both ends. The standard maximum pressure rating is 2.76 MPa (400 psi). The ordered lengths must be checked against the complete transducer system configuration before installation.\u003c\/p\u003e\n\u003ch3\u003e01 | Configuration Breakdown — Read the Ordering Code\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFull ordering code:\u003c\/strong\u003e 330762-AA-BB-CC-DD-EE-FF-GG-HH\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase model — 330762:\u003c\/strong\u003e Dual Triaxial High-Pressure Feedthrough.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA — 04:\u003c\/strong\u003e Armor at both ends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB — 80:\u003c\/strong\u003e Dimension 1 length: 8.0 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC — 80:\u003c\/strong\u003e Dimension 2 length: 8.0 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD — 75:\u003c\/strong\u003e Dimension 3 length: 7.5 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE — 75:\u003c\/strong\u003e Dimension 4 length: 7.5 metres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF — 94:\u003c\/strong\u003e Fluorocarbon O-ring material for exposure to butane, fuel oil, natural gas, petroleum oil, and turbine oil.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eG — 02:\u003c\/strong\u003e High-pressure end connector: male miniature coaxial connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH — 02:\u003c\/strong\u003e Low-pressure end connector: male miniature coaxial connector.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration check:\u003c\/strong\u003e The 7.5 m Dimension 3 length is 0.5 m shorter than the 8.0 m Dimension 1 length. The 7.5 m Dimension 4 length follows the same relationship to Dimension 2. Both satisfy the specified maximum-length rule for these dimensions.\u003c\/p\u003e\n\u003ch3\u003e02 | Engineering Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330762-04-80-80-75-75-94-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCable Routing Capacity\u003c\/th\u003e\n\u003ctd\u003eTwo cables; dual triaxial configuration for 3300 XL 11 mm probe systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum Pressure Rating\u003c\/th\u003e\n\u003ctd\u003e2.76 MPa (400 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e-26°C to +121°C (-15°F to +250°F), dependent on O-ring option 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e100% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum Recommended Bend Radius\u003c\/th\u003e\n\u003ctd\u003e25.4 mm (1.00 in), with or without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFitting Material\u003c\/th\u003e\n\u003ctd\u003e303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eO-Ring Material\u003c\/th\u003e\n\u003ctd\u003eFluorocarbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHigh-Pressure End Connector\u003c\/th\u003e\n\u003ctd\u003eMale miniature coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLow-Pressure End Connector\u003c\/th\u003e\n\u003ctd\u003eMale miniature coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector Construction\u003c\/th\u003e\n\u003ctd\u003eCorrosion-resistant, gold-plated brass ClickLoc connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnector Tightening\u003c\/th\u003e\n\u003ctd\u003eFinger-tight connection when mating with compatible connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRoHS\u003c\/th\u003e\n\u003ctd\u003eEuropean Community Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eChina RoHS\u003c\/th\u003e\n\u003ctd\u003eAssociated cables have a 15-year EFUP designation in accordance with SJ\/T 11364-2024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e03 | Where This Feedthrough Fits\u003c\/h3\u003e\n\u003cp\u003eThe 330762 is intended for machinery where the internal machine pressure differs significantly from the ambient pressure at the point where probe cables exit the casing. It provides a controlled cable route through the pressure boundary without treating the cable penetration as an ordinary, unsealed pass-through.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressurized compressors:\u003c\/strong\u003e Route proximity-probe connections through the casing while maintaining the specified pressure boundary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam and process turbines:\u003c\/strong\u003e Support shaft-displacement and related proximity measurements where the installation design requires a high-pressure feedthrough.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial rotating equipment:\u003c\/strong\u003e Provide a two-cable penetration point for suitable proximity monitoring arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine protection systems:\u003c\/strong\u003e Support installations using compatible Bently Nevada proximity probes, extension cables, and Proximitor Sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit and maintenance projects:\u003c\/strong\u003e Replace a matching feedthrough when dimensions, pressure rating, connector gender, O-ring compatibility, and electrical system length have been verified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe product description identifies compatibility with 3300 XL 8 mm, 3300 XL 11 mm, and 3300 5 mm proximity probes. Confirm the complete probe, extension cable, feedthrough, and Proximitor Sensor arrangement for the specific installation. The cable routing capacity and this ordering configuration should not be treated as proof of compatibility with every probe or monitor combination.\u003c\/p\u003e\n\u003ch3\u003e04 | Installation and Selection Checks\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the pressure boundary.\u003c\/strong\u003e Verify that the machine's maximum operating pressure does not exceed 2.76 MPa (400 psi) for this standard configuration. Higher-pressure modified versions require separate confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the process medium.\u003c\/strong\u003e Option 94 uses fluorocarbon O-rings for the listed fluids and gases. Verify chemical compatibility against the actual medium, concentration, temperature, and operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch the electrical system length.\u003c\/strong\u003e Feedthrough lengths must be selected to maintain the required total transducer-system electrical length. Do not select cable dimensions from physical reach alone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify connector gender.\u003c\/strong\u003e This SKU specifies male miniature coaxial connectors at both the high-pressure and low-pressure ends. The mating components must have the correct complementary connector type. Confirm the probe-side and Proximitor Sensor-side interfaces before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the cable interfaces from water.\u003c\/strong\u003e The feedthrough is not designed to seal water away from its internal cable leads. Prevent water exposure on both the high-pressure and low-pressure cable-to-feedthrough interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eObserve the bend radius.\u003c\/strong\u003e Maintain a minimum recommended bend radius of 25.4 mm (1.00 in), whether the cable is armored or unarmored.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMate connectors correctly.\u003c\/strong\u003e Compatible ClickLoc connections require finger-tight torque only. Do not apply excessive force or use tools to tighten the connector unless the applicable manufacturer instructions specifically require it.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e05 | Field Diagnostics and Troubleshooting\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003ePossible Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow or reduced transducer output\u003c\/td\u003e\n\u003ctd\u003eWater intrusion at a cable-to-feedthrough interface; connector contamination; damaged cable or connection\u003c\/td\u003e\n\u003ctd\u003eInspect both interfaces for moisture and corrosion. Follow the approved procedure to isolate and test the probe, extension cable, feedthrough, and Proximitor Sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent measurement or unstable readings\u003c\/td\u003e\n\u003ctd\u003eLoose or incompatible connector mating; cable damage; mechanical strain or excessive bending\u003c\/td\u003e\n\u003ctd\u003eVerify connector compatibility and seating, inspect the cable route, and check the minimum bend radius. Compare readings with the equipment manufacturer's diagnostic procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure leakage around the penetration\u003c\/td\u003e\n\u003ctd\u003eO-ring damage, incorrect material selection, installation defects, or operation beyond the rated pressure\u003c\/td\u003e\n\u003ctd\u003eFollow site pressure-isolation and depressurization procedures before inspection. Check the seal specification and installation condition; do not exceed the rated pressure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected probe gap or measurement offset\u003c\/td\u003e\n\u003ctd\u003eIncorrect transducer-system electrical length, mismatched components, or a fault elsewhere in the measurement chain\u003c\/td\u003e\n\u003ctd\u003eVerify the complete probe, cable, feedthrough, and Proximitor Sensor configuration. Check the system against the applicable calibration and installation documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector will not mate correctly\u003c\/td\u003e\n\u003ctd\u003eIncorrect connector gender, incompatible connector type, or physical damage\u003c\/td\u003e\n\u003ctd\u003eConfirm the male connector specified at each end of this SKU and the complementary connector on each mating component. Do not force mismatched connectors together.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e The 330762 is a passive cable feedthrough, not an independent monitoring or diagnostic module. It does not generate alarm codes or identify a fault by itself. Diagnosis requires inspection and testing of the full proximity measurement chain and the machine pressure boundary.\u003c\/p\u003e\n\u003ch3\u003e06 | Important Pressure and Moisture Limitations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe standard maximum pressure rating is 2.76 MPa (400 psi).\u003c\/li\u003e\n\u003cli\u003eModified feedthroughs may be available for pressure sealing up to 6.89 MPa (999 psi). Confirm availability and the exact rating for the required configuration before use.\u003c\/li\u003e\n\u003cli\u003eThe feedthrough is not intended to prevent water from reaching its internal cable leads. Water entering either cable interface can cause a high-resistance electrical short and significantly reduce transducer-system output.\u003c\/li\u003e\n\u003cli\u003eO-ring compatibility must be evaluated for the actual gas or fluid. A matching part number alone does not replace a process-compatibility review.\u003c\/li\u003e\n\u003cli\u003eDo not open, remove, or service a feedthrough while the machine is pressurized. Follow the site's approved isolation, depressurization, and maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e07 | Global PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cblockquote\u003eFor the 330762-04-80-80-75-75-94-02-02, the main selection risks are not limited to the pressure rating. The ordered cable dimensions, the total transducer-system electrical length, the two male connector interfaces, and the fluorocarbon O-ring's compatibility with the process medium must all be checked together.\u003c\/blockquote\u003e\n\u003cp\u003eFor a replacement project, compare the full ordering code against the existing installation rather than matching only the base model 330762. Confirm the pressure requirement, the machine-side and ambient-side interfaces, the cable routing geometry, and the Proximitor Sensor connection before release for purchase.\u003c\/p\u003e\n\u003cp\u003ePay particular attention to the male connector specified at both ends. The general feedthrough arrangement may use different connector genders on the high-pressure and low-pressure sides, but this exact suffix configuration specifies male connectors at both ends. Verify the mating parts against the actual equipment and current manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003e08 | Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this feedthrough be used as a direct replacement for another 330762 unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without checking the complete suffix code. The armor selection, four length dimensions, O-ring material, and connector options can differ. Compare the installed unit's ordering code and confirm the required electrical length and connector interfaces before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the 400 psi rating mean the assembly is suitable for every pressurized gas or liquid?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Pressure rating alone does not establish process suitability. Check the operating temperature, seal compatibility, fitting condition, and actual process medium. Option 94 specifies fluorocarbon O-rings for the listed applications, but compatibility with the site's exact fluid or gas must still be confirmed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should be checked first if the proximity reading drops after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck for water exposure at both cable-to-feedthrough interfaces, connector mismatch or poor mating, and cable damage. Because moisture can create a high-resistance electrical short and substantially reduce output, inspect the interfaces before assuming the probe itself has failed. Follow the approved isolation and test procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can the correct feedthrough length be selected for an existing monitoring channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the complete transducer-system configuration, not only the distance through the machine wall. Verify the probe, extension cable, feedthrough dimensions, and Proximitor Sensor requirements so the system's specified electrical length is maintained. Confirm the ordering dimensions against the installation drawing or manufacturer documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Are the male connectors on both ends interchangeable with every 3300 XL probe and Proximitor Sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Connector gender and interface compatibility must be verified for each mating component. This exact SKU specifies male miniature coaxial connectors at both ends, so the probe-side and Proximitor Sensor-side mating interfaces must be suitable female connections. Do not force a connection or assume compatibility from the series name alone.\u003c\/p\u003e\n\u003ch3\u003e09 | Ordering, Warranty and Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 330762 Dual Triaxial High-Pressure Feedthrough\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdering Code:\u003c\/strong\u003e 330762-04-80-80-75-75-94-02-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA, as specified for this product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month factory\/seller warranty, subject to the seller's written warranty terms and confirmation of the supplied item's condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination, service availability, and shipment arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Target dispatch within 24–48 hours after order and payment confirmation, subject to stock availability and processing requirements. Confirm lead time before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore placing an order, provide the full model number and confirm the required pressure rating, process medium, connector interfaces, and system cable-length requirements. For modified high-pressure versions, request written confirmation of the available configuration and rated operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330762.png?v=1784533962\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67644306686134,"sku":"330762-04-80-80-75-75-94-02-02","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330762_67ae0d7c-f1d3-4f9e-8042-ad2cd8c7ae9e.png?v=1792047711","url":"https:\/\/www.plcsparehub.com\/products\/330762-04-80-80-75-75-94-02-02-bently-nevada-3300-xl-dual-triaxial-feedthrough","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}