{"product_id":"330730-080-12-05-bently-nevada-3300-xl-11mm-extension-cable-genuine","title":"330730-080-12-05 Bently Nevada 3300 XL 11mm Extension Cable | Genuine","description":"\u003ch3\u003e\u003cstrong\u003eProduct Technical Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e330730-080-12-05\u003c\/strong\u003e is an 8.0-meter high-performance extension cable engineered for the \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 3300 XL 11mm Series\u003c\/strong\u003e proximity transducer system. Designed to link 11mm eddy current probes with their corresponding Proximitor sensors, this component delivers linear gap voltage feedback across an extended 4.0 mm measurement sweep. Built with 75 Ω triaxial FEP insulation, the assembly ensures stable signal integrity across wide temperature swings and intense electromagnetic environments.\u003c\/p\u003e\n\u003cp\u003eFeaturing a factory-integrated FluidLoc cable design and a dedicated connector protector, the \u003cstrong style=\"color: #0056b3;\"\u003e330730-080-12-05\u003c\/strong\u003e blocks turbine oil, bearing lubricants, and moisture from wicking through internal conductor strands or corroding gold-plated ClickLoc terminals. This specific build delivers dependable non-contact vibration and axial position feedback on heavy machinery where mechanical clearances prevent direct sensor mounting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDuring machinery protection system upgrades, our vibration engineering specialists consistently choose the \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 3300 XL 11mm Series\u003c\/strong\u003e for critical turbomachinery loops. When routing cables inside steam turbine bearing pedestals or centrifugal compressor gearboxes, oil migration through standard wire strands often causes sensor drift and premature cable breakdown. The FluidLoc technology in the \u003cstrong style=\"color: #0056b3;\"\u003e330730-080-12-05\u003c\/strong\u003e eliminates oil leakage, while the gold-plated ClickLoc connector prevents vibration-induced connector loosening. We recommend using dedicated connector protectors instead of silicone tape whenever turbine oil exposure is likely.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003e330730\u003c\/strong\u003e — Base Model: 3300 XL 11 mm Extension Cable Assembly\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e[ -080 ] Cable Length Option:\u003c\/strong\u003e 8.0 Metres (26.2 Feet) total length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e[ -12 ] Connector and Cable Option:\u003c\/strong\u003e FluidLoc cable with integrated connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e[ -05 ] Agency Approval Option:\u003c\/strong\u003e Multiple Approvals (hazardous location certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameters \u0026amp; System Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 11mm Series\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003e330730-080-12-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type \u0026amp; Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial, fluoroethylene propylene (FEP) insulation with FluidLoc liquid-barrier construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc locking connector with elastomeric connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils), spanning from 0.5 mm (20 mils) to 4.5 mm (180 mils) gap distance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm (100 mils) nominal bias setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRCORE (center conductor): 0.6 ± 0.2 Ω | RJACKET (outer conductor): 2.0 ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical line capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating and storage: -51°C to +177°C (-60°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnarmored extension cable density: 45 g\/m (0.5 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm² (16 to 24 AWG) shielded triad cable up to 305 meters (1,000 feet) to monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment, Applications \u0026amp; Diagnostic Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Turbomachinery Monitoring:\u003c\/strong\u003e Ideal for steam turbines, gas turbines, and large multi-stage compressors requiring 11mm probes for wide linear gaps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrust Position Measurement:\u003c\/strong\u003e Tracks axial shaft displacement to prevent rotor-to-stator contact during thermal growth or thrust bearing breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Amplitude Radial Vibration:\u003c\/strong\u003e Monitors large journal bearing shaft orbits where standard 8mm probe ranges are insufficient.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e Supports real-time orbit plots, time waveform analysis, and automated alarms for unbalance, shaft crack detection, misalignment, and oil whirl.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison \u0026amp; Engineering Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eComparing configuration options within the \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 11mm Series\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cstrong style=\"color: #0056b3;\"\u003e330730-080-12-05\u003c\/strong\u003e:\u003c\/strong\u003e Standard 8.0-meter FluidLoc cable with connector protector for oily and moist enclosure environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330730-080-03-05-proximity-sensor-cable-bently-nevada-3300-xl\" target=\"_blank\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003e330730-080-03-05\u003c\/strong\u003e\u003c\/a\u003e: Features flexible AISI 302 stainless steel armor over FEP jacket for harsh mechanical impact protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Selection Note:\u003c\/strong\u003e Choose option -12 when the cable runs inside oil-filled bearing housings where liquid migration is the main threat. Choose option -03 when cable runs are exposed to sharp metal edges or high-traffic field walkways requiring crush resistance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Delivery \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipment Preparation:\u003c\/strong\u003e Orders undergo QA checking and package sealing within 24 to 48 hours of confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier:\u003c\/strong\u003e Direct priority door-to-door transit managed via FedEx, UPS, and DHL Express networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Policy:\u003c\/strong\u003e Backed by a 12-month quality replacement warranty against functional defect or material failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eField Engineering FAQ \u0026amp; Maintenance Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What total system length does an 8.0m extension cable create when combined with an 11mm probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Combining an 8.0m cable with a 1.0m probe creates a 9.0m system, requiring a matching 9.0m Proximitor sensor for accurate calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: When should engineers choose FluidLoc extension cables over standard triaxial cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Specify FluidLoc cables whenever routing wire through oil-lubricated bearing housings to stop oil from wicking along the conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I shorten or splice an extension cable during field installation if it is too long?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Never cut or splice eddy current cables; altering the length shifts system impedance and invalidates scale factor calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is silicone tape discouraged for connector sealing in turbine environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Synthetic turbine oils erode silicone tape over time; use elastomeric connector protectors for long-term liquid barrier performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do ClickLoc connectors prevent signal loss under high machine vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ClickLoc connectors feature a positive tactile lock that holds under continuous high-g vibration without safety wire.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730.png?v=1783069039\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013957312694,"sku":"330730-080-12-05","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730-080-00-CN.jpg?v=1786091989","url":"https:\/\/www.plcsparehub.com\/products\/330730-080-12-05-bently-nevada-3300-xl-11mm-extension-cable-genuine","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}