{"product_id":"330730-040-12-00-bently-nevada-3300-xl-cable-sensor-extension","title":"330730-040-12-00 Bently Nevada 3300 XL Cable Sensor Extension","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e is a heavy-duty 11 mm proximity transducer extension cable.\u003c\/p\u003e\n\u003cp\u003eEngineers design this 4-meter unit for non-contact vibration and axial position measurement.\u003c\/p\u003e\n\u003cp\u003eIt carries high-frequency eddy current signals between the sensing probe and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eThe patented FluidLoc design blocks oil migration through the internal conductor core.\u003c\/p\u003e\n\u003cp\u003eAn integrated connector protector guards electrical joints in wet rotating machinery bays.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe matrix below outlines part suffix specifications for model \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003ePart Number Component\u003c\/th\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eConfiguration Specification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330730\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003c\/span\u003e 11 mm Extension Cable Base Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-040\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluidLoc liquid-sealed cable with pre-installed connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard execution (No hazardous area approvals required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Architecture \u0026amp; Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTechnical parameters are organized below into clear structural categories.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Performance Parameters\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003c\/span\u003e 11 mm System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Length:\u003c\/strong\u003e 5 or 9 meters (probe plus extension cable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Measurement Range:\u003c\/strong\u003e 4.0 mm (160 mils), spanning -1 Vdc to -17 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Range (DSL):\u003c\/strong\u003e 0.5 mm to 5.0 mm (20 to 200 mils), spanning -1 Vdc to -19 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Gap Setting:\u003c\/strong\u003e 2.5 mm (100 mils) target distance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncremental Scale Factor (ISF):\u003c\/strong\u003e 3.94 V\/mm (100 mV\/mil) +\/-10%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacitance Density:\u003c\/strong\u003e 69.9 pF\/m (21.3 pF\/ft) typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore Conductor Resistance (RCORE):\u003c\/strong\u003e 1.0 +\/- 0.25 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Jacket Resistance (RJACKET):\u003c\/strong\u003e 0.3 +\/- 0.1 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Material:\u003c\/strong\u003e 75 Ohm triaxial fluoroethylene propylene (FEP) insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Plating:\u003c\/strong\u003e Corrosion-resistant gold-plated brass contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical \u0026amp; Environmental Tolerances\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating \u0026amp; Storage Temperature:\u003c\/strong\u003e -52 °C to +177 °C (-62 °F to +351 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Cable Weight:\u003c\/strong\u003e Unarmored 45 g\/m (0.5 oz\/ft) \/ Total ~0.18 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensile Rating (Probe-to-Lead):\u003c\/strong\u003e 330 N (75 lbs) maximum rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensile Rating (Lead-to-Extension):\u003c\/strong\u003e 270 N (60 lbs) maximum rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Range:\u003c\/strong\u003e 0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad wire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection Comparison \u0026amp; Technical Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompare key specs below between model \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e and alternative variants.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003cthead\u003e\n\u003ctr bgcolor=\"#f2f2f2\"\u003e\n\u003cth\u003eTechnical Specification\u003c\/th\u003e\n\u003cth\u003e330730-040-12-00 (Current Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330730-080-03-05-proximity-sensor-cable-bently-nevada-3300-xl\"\u003e330730-080-03-05\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Physical Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard unarmored FEP jacket\u003c\/td\u003e\n\u003ctd\u003eStainless steel flexible armor with outer FEP jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLiquid Barrier Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluidLoc oil-sealed internal core\u003c\/td\u003e\n\u003ctd\u003eStandard non-FluidLoc internal construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory pre-installed connector protector\u003c\/td\u003e\n\u003ctd\u003eStandard unshielded connector interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (00 = Not required)创\u003c\/td\u003e\n\u003ctd\u003eMultiple agency approvals (05 = CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Selection Advice:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSelect the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e for unarmored conduit runs inside oil-filled bearing housings.\u003c\/p\u003e\n\u003cp\u003eThe FluidLoc core prevents turbine oil from wicking along internal conductor strands into junction boxes.\u003c\/p\u003e\n\u003cp\u003eWhen long external cable runs require physical impact resistance or explosion-proof certifications, select the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330730-080-03-05-proximity-sensor-cable-bently-nevada-3300-xl\"\u003e330730-080-03-05\u003c\/a\u003e instead.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTurbomachinery operators rely on this extension cable for critical health monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam \u0026amp; Gas Turbines:\u003c\/strong\u003e Monitors rotor shaft position and main bearing vibration levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e Measures high-speed axial displacement under heavy process loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Boiler Feed Pumps:\u003c\/strong\u003e Tracks radial shaft tilt and bearing wear during continuous operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGearboxes \u0026amp; Generators:\u003c\/strong\u003e Connects internal sensors through oil splash zones to external junction boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Field Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper electrical characteristics enable continuous online monitoring system diagnostics.\u003c\/p\u003e\n\u003cp\u003eThe Proximitor sensor measures core resistance (RCORE) and jacket resistance (RJACKET) continuously.\u003c\/p\u003e\n\u003cp\u003eAn open core circuit or ground fault shifts the DC bias voltage out of the -1 Vdc to -17 Vdc linear window.\u003c\/p\u003e\n\u003cp\u003eThis voltage anomaly triggers instant NOT OK alarm states on Machinery Protection Systems.\u003c\/p\u003e\n\u003cp\u003eThe pre-installed connector protector prevents moisture ingress from degrading signal frequency response.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur machinery monitoring specialists supported a power plant during a gas turbine overhaul.\u003c\/p\u003e\n\u003cp\u003eThe plant reported intermittent NOT OK alarms on their thrust bearing proximity channels.\u003c\/p\u003e\n\u003cp\u003eInspection revealed turbine lube oil had wicked through standard cables into the dry junction box.\u003c\/p\u003e\n\u003cp\u003eOil saturation altered signal capacitance and created high-frequency signal roll-off errors.\u003c\/p\u003e\n\u003cp\u003eReplacing worn lines with the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e FluidLoc cable solved oil leakage completely.\u003c\/p\u003e\n\u003cp\u003eIts rubber connector boot prevented moisture contamination during high-pressure washdowns.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSelection \u0026amp; Installation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFollow these field engineering guidelines before installing sensor extension cables.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalculate total system length carefully to ensure matching with 5 m or 9 m Proximitor calibrations.\u003c\/li\u003e\n\u003cli\u003eUse silicone tape only when connector protectors are unavailable and oil exposure is absent.\u003c\/li\u003e\n\u003cli\u003eAvoid installing silicone-wrapped connections directly inside active turbine oil sump compartments.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum bend radii to prevent internal coaxial dielectric insulation strain.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring uses shielded triad cable for distances up to 305 meters (1000 feet).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Logistics \u0026amp; 12-Month Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWe supply authentic industrial monitoring hardware with complete logistics support.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330730-040-12-00\u003c\/strong\u003e\u003c\/span\u003e cable in sealed protective packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Complete 12-Month replacement warranty included with purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier:\u003c\/strong\u003e Direct international express delivery via FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Lead Time:\u003c\/strong\u003e Standard orders ship out within 24 to 48 hours after payment processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific functional benefit does the FluidLoc option offer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It prevents oil and pressurized fluids from leaking through internal cable strands into external enclosures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use silicone tape inside an oil-filled bearing casing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Standard silicone wrapping degrades when exposed continuously to hot synthetic turbine oils.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does cable length affect total proximity transducer system calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Extension cable length must match the Proximitor sensor calibration tuning (5-meter or 9-meter overall length).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum recommended field wiring distance from Proximitor to monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: You can run up to 305 meters (1000 feet) of 16-24 AWG shielded triad field cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How quickly will my shipment dispatch after order confirmation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: We process and dispatch all orders within 24 to 48 hours using express couriers like FedEx, UPS, or DHL.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730.png?v=1783069039\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013957050550,"sku":"330730-040-12-00","price":143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730-080-02-CN.jpg?v=1787032782","url":"https:\/\/www.plcsparehub.com\/products\/330730-040-12-00-bently-nevada-3300-xl-cable-sensor-extension","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}