{"product_id":"330730-040-03-00-extension-cable-bently-nevada-3300-xl-11mm-armored","title":"330730-040-03-00 Extension Cable Bently Nevada 3300 XL 11mm Armored","description":"\u003ch3\u003e\u003cb\u003eProduct Introduction\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e serves as a 4.0-meter armored component for the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada 3300 XL 11mm Series\u003c\/span\u003e\u003c\/b\u003e proximity transducer system. Designed for critical machinery protection, this 75 Ω triaxial cable transmits high-frequency eddy current signals between the probe and Proximitor sensor. It incorporates flexible AISI 302 stainless steel armor with an FEP outer jacket and a factory-installed connector protector for extreme field reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePart Number Configuration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e330730\u003c\/b\u003e — \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e3300 XL 11mm\u003c\/span\u003e\u003c\/b\u003e Extension Cable Base Model\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e-040\u003c\/b\u003e — Cable Length Option\n\u003cul\u003e\n\u003cli\u003e4.0 meters \/ 13.1 feet length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-03\u003c\/b\u003e — Connector \u0026amp; Armor Option\n\u003cul\u003e\n\u003cli\u003eArmored cable (Flexible AISI 302 SST with FEP jacket)\u003c\/li\u003e\n\u003cli\u003eIncludes factory-installed connector protector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-00\u003c\/b\u003e — Agency Approval Option\n\u003cul\u003e\n\u003cli\u003eStandard configuration without hazardous area approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer Brand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel Part Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Series\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e3300 XL 11mm Series\u003c\/span\u003e Transducer System\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCountry of Origin\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCable Construction\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eArmor \u0026amp; Outer Protection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible AISI 302 SST armor with FEP jacket \u0026amp; connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Resistance (R CORE)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 ± 0.25 Ohms (Center conductor to center conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Resistance (R JACKET)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 ± 0.1 Ohms (Coaxial conductor to coaxial conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCable Capacitance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSystem Linear Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils) from ~0.5 to 4.5 mm (-1 to -17 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eExtended DSL Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 5.0 mm (-1 to -19 Vdc, non-zener barrier setups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIncremental Scale Factor (ISF)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) ±10% including interchangeability error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRecommended Gap Setting\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm (100 mils) target offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector Metallurgy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass click-lock connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTensile Load Capacity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lbs) maximum pull strength at connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F) continuous exposure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Armored Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.56 kg (140 g\/m for armored cable jacket assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eField Wiring Compatibility\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm² (16 to 24 AWG) 3-conductor shielded triad cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eTarget Machinery \u0026amp; Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHeavy Industrial Machinery:\u003c\/b\u003e Turbo-compressors, large industrial gearboxes, heavy-duty boiler feed pumps, and hydro-turbines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCondition Monitoring Parameters:\u003c\/b\u003e Shaft radial vibration detection, axial thrust position tracking, keyphasor speed sensing, and phase reference monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField Environment Readiness:\u003c\/b\u003e Designed specifically for harsh oil mist, high humidity, or wet sump locations where fluid ingress threatens signal purity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guidance \u0026amp; Fluid Protection Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eConnector Integrity:\u003c\/b\u003e Pre-installed connector protectors guard gold-plated brass contacts from oil, moisture, and chemical contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFluid Seal Technology:\u003c\/b\u003e Compatible with FluidLoc option configurations to stop internal lube oil migration along the cable path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSilicone Tape Alternative:\u003c\/b\u003e Includes self-fusing silicone wrapping tape for dry or general-purpose junction box seal applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWiring Limits:\u003c\/b\u003e Maintains signal integrity up to 305 meters (1,000 feet) maximum distance to the Proximitor sensor chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCommercial Terms \u0026amp; Dispatch Details\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Coverage:\u003c\/b\u003e Backed by a full \u003cb\u003e12-Month Warranty\u003c\/b\u003e against defects in material and workmanship.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress Logistics:\u003c\/b\u003e Fast order dispatch within \u003cb\u003e24-48 hours\u003c\/b\u003e via premier air couriers \u003cb\u003eFedEx, UPS, or DHL\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackage Contents:\u003c\/b\u003e 1x \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e armored extension cable with factory connector protector and silicone tape roll.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eIn high-vibration rotating machinery installations, connector degradation represents a frequent cause of false vibration spikes. Our field specialists observe that unarmored cabling operating near hot turbine casings often suffers mechanical chafing or oil penetration inside non-sealed junction boxes.\u003c\/p\u003e\n\u003cp\u003eDuring a recent gas booster compressor audit, unstable -24V DC gap voltages were traced to oil contamination inside an unprotected probe-to-cable joint. Replacing the degraded link with the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e extension cable—utilizing its integrated stainless steel armor and seal protector—immediately stabilized the signal. The machine achieved consistent 3.94 V\/mm scale factor performance across a 12-month continuous run cycle.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSelection \u0026amp; Cable Length Matching Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eRule 1 (System Length Alignment):\u003c\/b\u003e Always match probe length plus extension cable length to the total Proximitor calibration requirement (e.g., a 1.0-meter probe requires a 4.0-meter cable like \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e to form a 5.0-meter total system).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRule 2 (Armor Selection):\u003c\/b\u003e Choose option -03 stainless steel armor whenever routing cable through exposed machinery frames, open cable trays, or high foot-traffic skid areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRule 3 (Environmental Exposure):\u003c\/b\u003e Use the included connector protector instead of silicone tape if the cable joint faces direct exposure to synthetic turbine lubricants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this 4.0-meter extension cable be paired with a 3300 XL 5mm or 8mm probe?\u003c\/b\u003e\u003cbr\u003eA: No, the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e330730-040-03-00\u003c\/span\u003e\u003c\/b\u003e cable is specifically engineered and impedance-matched for the \u003cb\u003e\u003cspan style=\"color: #0056b3;\"\u003e3300 XL 11mm Series\u003c\/span\u003e\u003c\/b\u003e probe systems.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eQ: What is the main operational benefit of option -03 compared to standard unarmored extension cables?\u003c\/b\u003e\u003cbr\u003eA: Option -03 provides flexible AISI 302 stainless steel armor over an FEP jacket, preventing mechanical crushing, sharp bends, and oil ingress at the connector.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eQ: How do field technicians verify correct conductor continuity during routine loop checks?\u003c\/b\u003e\u003cbr\u003eA: Measure DC resistance across the center conductor (R CORE = 1.0 ± 0.25 Ω) and outer jacket conductor (R JACKET = 0.3 ± 0.1 Ω) using a precision digital multimeter.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eQ: Is silicone wrapping tape sufficient for sealing connections inside turbine oil-filled bearing housings?\u003c\/b\u003e\u003cbr\u003eA: No, silicone tape degrades under continuous contact with hot turbine oil. Use the integrated connector protector or optional FluidLoc seals for oil-immersed applications.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eQ: How does cable capacitance impact signal transmission over long field wiring runs?\u003c\/b\u003e\u003cbr\u003eA: With a rated capacitance of 69.9 pF\/m, this cable preserves dynamic frequency response from 0 to 10 kHz when connected within the recommended 305-meter distance to the monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730.png?v=1783069039\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013956788406,"sku":"330730-040-03-00","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330730-080-01-00_63dab9ff-5fd1-42fd-a9e9-0d50bf3f4de6.jpg?v=1788494277","url":"https:\/\/www.plcsparehub.com\/products\/330730-040-03-00-extension-cable-bently-nevada-3300-xl-11mm-armored","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}