{"product_id":"330709-000-230-50-02-05-bently-nevada-3300-xl-11mm-proximity-probe","title":"330709-000-230-50-02-05 Bently Nevada 3300 XL 11mm Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eEngineering System Architecture \u0026amp; Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e330709-000-230-50-02-05\u003c\/strong\u003e is an advanced \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e engineered for high-precision vibration and position measurement in critical rotating machinery.\u003c\/p\u003e\n\u003cp\u003eManufactured in the United States, this robust sensor system delivers exceptional linearity, thermal stability, and reliable performance under severe industrial operating conditions.\u003c\/p\u003e\n\u003cp\u003eDesigned specifically to interface with matching 5-meter Proximitor sensors, it ensures precise phase and amplitude signal fidelity for machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #dee2e6; padding: 10px; text-align: left;\"\u003eComponent Option\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dee2e6; padding: 10px; text-align: left;\"\u003eSelected Code\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dee2e6; padding: 10px; text-align: left;\"\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eBase Model \u0026amp; Thread\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e330709\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e3300 XL 11 mm Probe, M16 x 1.5 thread, unarmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e000\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e0 mm unthreaded case extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e230\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e230 mm total case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e50\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e5.0 meters (16.4 feet) — requires 5m Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eConnector \u0026amp; Cable Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e02\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003e05\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dee2e6; padding: 10px;\"\u003eMultiple hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications and Metrology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: disc; margin-left: 20px; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Resistance:\u003c\/strong\u003e Center conductor to outer conductor resistance (\u003cspan style=\"font-family: monospace;\"\u003eR\u003csub\u003ePROBE\u003c\/sub\u003e\u003c\/span\u003e) measures 7.2 ± 0.8 Ω for the 5.0m length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Requirements:\u003c\/strong\u003e Requires a recommended minimum flat surface diameter of 30.5 mm (1.2 in) and shaft diameter of 152 mm (6.0 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials:\u003c\/strong\u003e Polyphenylene sulfide (PPS) probe tip, AISI 304 stainless steel case, and 75 Ω triaxial FEP-insulated cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e M16x1.5 case thread recommended torque is 21.1 N•m (187 in•lb); maximum rated torque is 63.3 N•m (560 in•lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Limits:\u003c\/strong\u003e Finger-tight recommended connector torque; maximum 0.565 N•m (5 in•lb). Minimum bend radius is 25.4 mm (1.0 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Ratings:\u003c\/strong\u003e Operating and storage temperature range spans -52°C to +177°C (-62°F to +351°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Comparison and Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting proximity hardware for your vibration monitoring architecture, evaluating dimensional and electrical configurations is critical:\u003c\/p\u003e\n\u003cul style=\"list-style-type: disc; margin-left: 20px; margin-bottom: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Target Model:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e330709-000-230-50-02-05\u003c\/strong\u003e features an extended 230 mm case length and a 5.0-meter cable, making it ideal for deep-bore machinery mounting where greater case reach is necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Comparison Model:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330709-000-080-90-12-05-bently-nevada-3300-xl-11mm-proximity-probe\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong style=\"color: #0056b3;\"\u003e330709-000-080-90-12-05\u003c\/strong\u003e\u003c\/a\u003e utilizes a shorter 80 mm case length combined with a 9.0-meter cable and armored cable construction (option 12).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Recommendation:\u003c\/strong\u003e Choose the 230 mm case variant when your mounting bracket requires deeper penetration past thick machine casings. Conversely, select the shorter case with a 9-meter cable variant if your junction box is located farther from the bearing housing and mechanical protection against physical abrasion (armor) is mandatory for the longer cable run.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why must this 5-meter probe be paired exclusively with a 5-meter matched Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The LC oscillator circuit inside the Proximitor sensor is factory-calibrated to match the exact electrical capacitance and resistance of the 5.0-meter triaxial cable assembly to maintain mV\/mil output linearity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What precautions should technicians observe when installing probes in sub-zero ambient conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Exposing the probe to temperatures below -34°C (-30°F) prior to or during installation can cause premature failure of the tip pressure seal due to polymer brittleness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the M16x1.5 thread engagement limit affect mechanical depth positioning?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The maximum thread engagement length is 24 mm; installers must ensure lock nuts and mounting threads do not exceed this limit to avoid stressing the probe body.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the temperature classification limits for EPL Ga installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Under EPL Ga certification, the probe supports T1 classification up to +232°C ambient, scaling down to T4 for ambient temperatures up to +80°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the ClickLoc connector design prevent signal interruption from machine vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc mechanism provides a secure, tactile locking click that prevents micro-motion and intermittent electrical contact caused by continuous high-frequency plant vibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcurement and Engineering Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVerify your machinery casing thread specifications and proximity cable length requirements prior to order placement.\u003c\/p\u003e\n\u003cp\u003eEnsure your installation team adheres to recommended torque specifications to prevent thread galling or seal damage.\u003c\/p\u003e\n\u003cp\u003eContact our industrial automation engineering sales desk today for official quotations, lead times, and global delivery inquiries.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330701-330710_277166d5-e9a1-4262-be00-6e9f400c6615.png?v=1793762920\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013956493494,"sku":"330709-000-230-50-02-05","price":147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330709_5.jpg?v=1789109043","url":"https:\/\/www.plcsparehub.com\/products\/330709-000-230-50-02-05-bently-nevada-3300-xl-11mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}