{"product_id":"330709-000-230-10-12-05-bently-nevada-3300-xl-11mm-proximity-probe","title":"330709-000-230-10-12-05 Bently Nevada 3300 XL 11mm Proximity Probe","description":"\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e Product Overview\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e is an advanced eddy-current transducer designed within the \u003cstrong\u003eBently Nevada 3300 XL 11 mm\u003c\/strong\u003e proximity probe series. Featuring a robust M16x1.5 thread profile and an unarmored configuration, this 11mm probe delivers superior linear range and expanded target clearance capabilities for high-performance industrial machinery monitoring.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown and Suffix Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model: 330709\u003c\/strong\u003e - 3300 XL 11 mm Probe, M16x1.5 thread, without armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Length Option: 000\u003c\/strong\u003e - 0 mm unthreaded length directly beneath the probe case thread shoulder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length Option: 230\u003c\/strong\u003e - 230 mm total physical length configuration of the probe housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Option: 10\u003c\/strong\u003e - 1.0 metre (3.3 feet) integral cable length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector and Cable-Type Option: 12\u003c\/strong\u003e - Miniature coaxial ClickLoc connector paired with a FluidLoc cable design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option: 05\u003c\/strong\u003e - Multiple hazardous area and regional certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Metric\u003c\/th\u003e\n\u003cth\u003eEngineering Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBently Nevada 3300 XL 11 mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.9 ± 0.5 Ω (Center to outer conductor for 1.0m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target \u0026amp; Shaft Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat target diameter min. 30.5 mm (1.2 in); Shaft diameter min. 152 mm (6.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Torque Limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63.3 N·m (560 in·lb) maximum rated, 21.1 N·m (187 in·lb) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F) standard operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eLogistics, Fulfillment, and Warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Carriers:\u003c\/strong\u003e Expedited international shipping handled securely via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Speed:\u003c\/strong\u003e Standard processing, packaging, and dispatch completed within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Fully protected by a comprehensive 12-month operational warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment, Applications, and Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachinery Platforms:\u003c\/strong\u003e Large industrial steam turbines, heavy-duty gas compressors, hydro turbines, and large multi-stage pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e Measures broad-band shaft vibration, axial rotor thrust, and relative differential expansion with heightened sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Advantage:\u003c\/strong\u003e The larger 11mm tip footprint allows accurate measurement on shafts with larger runout tolerances or specialized surface coatings compared to standard 8mm systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModel Selection and Technical Comparison\u003c\/h3\u003e\n\u003cp\u003eWhen engineering replacement loops or adapting sensor geometries, technicians frequently compare alternative configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330709-000-230-10-12-05 (Current Model):\u003c\/strong\u003e Features a 230mm overall case length, M16x1.5 thread, FluidLoc cable, ClickLoc connector, and multi-approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330709-000-050-10-02-00-bently-nevada-3300-xl-11-mm-proximity-probe\"\u003e330709-000-050-10-02-00\u003c\/a\u003e:\u003c\/strong\u003e Features a much shorter 50 mm case length option (-050) alongside standard coaxial cable layouts (-02) and basic unapproved baseline ratings (-00), designed for restricted installation depths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guidance:\u003c\/strong\u003e When transitioning between parts like \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330709-000-050-10-02-00-bently-nevada-3300-xl-11-mm-proximity-probe\"\u003e330709-000-050-10-02-00\u003c\/a\u003e and the \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e, verify the physical penetration depth inside the machine well. The extended 230mm housing requires deeper bracket clearance, whereas short-case variants suit cramped mounting blocks.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003eA vital field observation for the \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e relates to fluid migration protection. The FluidLoc cable suffix (-12) utilizes an internal barrier to stop oil from wicking through the cable strands into the connector housing. In high-pressure turbine lubrication environments, standard cables often allow oil to breach the junction box, whereas FluidLoc technology prevents signal shunting and erratic voltage spikes.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What specific installation torque should technicians apply to the M16x1.5 thread of the \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Technicians should target a recommended torque value of 21.1 N·m (187 in·lb), ensuring they never exceed the maximum rated threshold of 63.3 N·m (560 in·lb) to avoid damaging the probe casing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How do temperature classes vary for hazardous area installations under EPL Ga and Gc ratings?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The temperature classification shifts depending on ambient thresholds, ranging from T1 at an ambient temperature of -55°C up to +232°C, down to T5 at -55°C up to +40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Why is a larger flat target diameter of at least 30.5 mm required for the \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Because the 3300 XL 11mm probe generates a wider electromagnetic field than 8mm probes, it requires a larger target surface area to prevent edge-effect distortion and linear calibration errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What potential damage occurs if the probe is exposed to temperatures below -34°C during storage or installation?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Sustained exposure to deep cold conditions below -34°C can embrittle the internal sealing components, causing premature failure of the pressure boundary seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can the FluidLoc cable on the \u003cstrong\u003e330709-000-230-10-12-05\u003c\/strong\u003e eliminate the need for external oil-seal junction boxes?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e While FluidLoc cable prevents oil migration down the internal conductor bundle, standard industrial wiring practices still dictate proper enclosure sealing to protect downstream Proximitor electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330701-330710_2e2c2d04-8ed6-4347-bdcc-6b9f794e0805.png?v=1787902119\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330701-330710_2e2c2d04-8ed6-4347-bdcc-6b9f794e0805.png?v=1787902119\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013956427958,"sku":"330709-000-230-10-12-05","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330709_16_cf28c83e-f075-454c-a6d7-522fd178c078.jpg?v=1789109043","url":"https:\/\/www.plcsparehub.com\/products\/330709-000-230-10-12-05-bently-nevada-3300-xl-11mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}