{"product_id":"330703-000-060-10-11-05-bently-nevada-3300-xl-11mm-metric-proximity-probe","title":"330703-000-060-10-11-05 Bently Nevada 3300 XL 11mm Metric Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #e87524;\"\u003eBently Nevada 330703-000-060-10-11-05\u003c\/span\u003e\u003c\/strong\u003e is a metric 3300 XL 11 mm proximity probe.\u003c\/p\u003e\n\u003cp\u003eIt measures shaft displacement and vibration in rotating machinery. The probe works with compatible 3300 XL proximity transducer systems.\u003c\/p\u003e\n\u003cp\u003eThis configuration features an \u003cstrong\u003eM14 x 1.5 threaded case\u003c\/strong\u003e without armor. It includes a 1.0-meter FEP-insulated triaxial cable and a miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003cp\u003eThe probe supports machinery condition monitoring in turbines, compressors, pumps, and other rotating equipment. Its stainless steel case provides mechanical protection in industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 3300 XL 11 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 330703 Metric Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 330703-000-060-10-11-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and Original in Factory Packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Warranty:\u003c\/strong\u003e 12 Months\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330703-000-060-10-11-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetric Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShaft displacement and vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM14 x 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnarmored threaded probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector protector included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene propylene (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.9 ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Installation Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.1 N·m (187 in·lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63.3 N·m (560 in·lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Thread Engagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 – Multiple approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement and Electrical Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe probe operates as part of a compatible 3300 XL proximity measurement system. Its electrical output depends on the complete probe, extension cable, and Proximitor sensor configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e The supplied data does not specify a standalone calibrated measurement range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e The supplied configuration data does not specify a frequency response value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e System sensitivity depends on the matched Proximitor sensor and calibration configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e Use the applicable 3300 XL system calibration specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e System resolution depends on the connected monitoring electronics and signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Resistance:\u003c\/strong\u003e 5.9 ± 0.5 Ω for the 1.0-meter probe configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e Do not treat probe resistance as measurement sensitivity. Verify the complete transducer system before setting monitoring limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMagnetic Field Interference Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBently Nevada specifies output voltage under 60 Hz magnetic fields up to 300 gauss. The following values apply to a five-meter system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProbe Gap\u003c\/th\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5 mm (20 mil)\u003c\/td\u003e\n\u003ctd\u003e0.001 mil pp\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 mm (100 mil)\u003c\/td\u003e\n\u003ctd\u003e0.009 mil pp\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.6 mm (180 mil)\u003c\/td\u003e\n\u003ctd\u003e0.027 mil pp\/gauss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese figures describe magnetic-field-induced output. They do not represent the probe's measurement sensitivity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTemperature Classification and Environmental Resistance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe probe supports demanding industrial temperature conditions. Actual temperature classification depends on the equipment protection level and installation ambient temperature.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Class\u003c\/th\u003e\n\u003cth\u003eAmbient Temperature Range – EPL Ga and Gc\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT1\u003c\/td\u003e\n\u003ctd\u003e-55°C to +232°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT2\u003c\/td\u003e\n\u003ctd\u003e-55°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT3\u003c\/td\u003e\n\u003ctd\u003e-55°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003ctd\u003e-55°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003ctd\u003e-55°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEPL Dc temperature classification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Surface Temperature\u003c\/th\u003e\n\u003cth\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e280°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +232°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e225°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e170°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e130°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e105°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90°C\u003c\/td\u003e\n\u003ctd\u003e-55°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant installation warning:\u003c\/strong\u003e Temperatures below -34°C may cause premature pressure seal failure. Consider this limitation when selecting installation locations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the mounting thread:\u003c\/strong\u003e Confirm the M14 x 1.5 mounting port before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify engagement:\u003c\/strong\u003e Keep thread engagement within 21 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the mounting torque:\u003c\/strong\u003e Use 21.1 N·m as the recommended torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid excessive force:\u003c\/strong\u003e Never exceed the 63.3 N·m maximum case torque.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the probe tip:\u003c\/strong\u003e Check for contamination, impact damage, and surface defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the cable:\u003c\/strong\u003e Avoid sharp bends, abrasion, and excessive mechanical tension.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the connector:\u003c\/strong\u003e Keep the ClickLoc connection clean and properly seated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFollow the equipment manufacturer's installation procedure. Confirm the mounting clearance and target material before commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommissioning, Testing, and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect commissioning helps maintain reliable shaft vibration and displacement measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCheck the probe model and cable length against the system drawings.\u003c\/li\u003e\n\u003cli\u003eVerify electrical continuity and probe resistance before connection.\u003c\/li\u003e\n\u003cli\u003eInspect the cable and connector for mechanical damage.\u003c\/li\u003e\n\u003cli\u003eUse the specified compatible Proximitor sensor and extension cable.\u003c\/li\u003e\n\u003cli\u003eSet the probe gap according to the applicable system calibration procedure.\u003c\/li\u003e\n\u003cli\u003eCompare the static gap voltage with the expected commissioning value.\u003c\/li\u003e\n\u003cli\u003eCheck the vibration signal after machinery startup.\u003c\/li\u003e\n\u003cli\u003eRecord baseline readings for future condition monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInspect the mounting threads, cable routing, and connector during planned maintenance. Investigate unstable readings before replacing the probe.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330703\u003c\/strong\u003e belongs to the Bently Nevada 3300 XL 11 mm proximity probe family.\u003c\/p\u003e\n\u003cp\u003eSystem compatibility requires more than matching the probe series. Verify the complete transducer chain before installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible 3300 XL 11 mm measurement system configurations.\u003c\/li\u003e\n\u003cli\u003eMatching Proximitor sensor requirements.\u003c\/li\u003e\n\u003cli\u003eCorrect extension cable electrical characteristics.\u003c\/li\u003e\n\u003cli\u003eCompatible connector and cable interface.\u003c\/li\u003e\n\u003cli\u003eCorrect total system length and calibration requirements.\u003c\/li\u003e\n\u003cli\u003eSuitable mounting dimensions and shaft target material.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine shaft vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine shaft displacement measurement.\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressor condition monitoring.\u003c\/li\u003e\n\u003cli\u003eIndustrial pump shaft position monitoring.\u003c\/li\u003e\n\u003cli\u003eRotating machinery protection and diagnostic systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eConsider the following alternative when your installation requires a different overall case length or connector configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Item\u003c\/th\u003e\n\u003cth\u003e330703-000-060-10-11-05\u003c\/th\u003e\n\u003cth\u003eAlternative Model\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330703\u003c\/td\u003e\n\u003ctd\u003e330703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e60.0 mm\u003c\/td\u003e\n\u003ctd\u003e80.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e00 mm\u003c\/td\u003e\n\u003ctd\u003e00 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Probe Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003ctd\u003eVerify option code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection Consideration\u003c\/td\u003e\n\u003ctd\u003e60 mm case requirement\u003c\/td\u003e\n\u003ctd\u003e80 mm case requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAlternative product:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330703-000-080-10-02-00-bently-nevada-3300-xl-11mm-metric-proximity-probe\"\u003e\u003cstrong\u003eBently Nevada 330703-000-080-10-02-00 3300 XL 11 mm Metric Proximity Probe\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering selection advice:\u003c\/strong\u003e The 60 mm and 80 mm versions have different case lengths. Check mounting depth and probe positioning before substitution. Also verify the connector and cable options. Do not select a replacement based only on the 330703 model number.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Approval Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code specifies approval option \u003cstrong\u003e05 – Multiple approvals\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eConfirm the applicable approval certificates against the complete part number and equipment installation requirements.\u003c\/p\u003e\n\u003cp\u003eThe temperature classifications listed above provide additional guidance for hazardous-area application assessment. Do not assume every temperature class applies to every installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Delivery\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 3300 XL 11 mm Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 330703-000-060-10-11-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and Original in Factory Packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 Months Factory Warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Part number and product condition verification before shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandard packing contents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Bently Nevada 330703 proximity probe.\u003c\/li\u003e\n\u003cli\u003eFactory packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional accessories are not included unless specified in the order.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What does Bently Nevada 330703-000-060-10-11-05 represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt identifies a 3300 XL 11 mm metric proximity probe. This version has an M14 x 1.5 thread, 60 mm case, and 1.0-meter cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What is the difference between the 330703 and 3300 XL 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThey belong to different probe families. Their mechanical dimensions and electrical characteristics differ. Always use the specified probe family for the installed Proximitor system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can this probe connect directly to a PLC analog input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The probe requires a compatible Proximitor sensor or measurement interface. The interface conditions the probe signal for monitoring equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Can I replace an 80 mm case probe with this 60 mm version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without checking the mounting arrangement. The shorter case changes the available installation depth and probe positioning. Confirm the required clearance before substitution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What causes unstable readings after probe installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCommon causes include incorrect probe gap, loose connectors, damaged cables, and incompatible extension components. Check the complete transducer chain before replacing the probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. How should I select the correct 330703 probe configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the thread size, case length, total cable length, connector type, and approval option. Match these details against the existing equipment documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. Does the 1.0-meter cable determine the complete measurement system length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The total system length includes the probe cable and compatible extension cable. Verify the required system configuration before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Can this probe operate continuously at +177°C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIts specified operating temperature reaches +177°C. However, hazardous-area temperature classifications may impose additional limits. Check the installation conditions and applicable approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9. What should I check before ordering a replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the complete part number from the installed probe. Check the case dimensions, connector, cable length, and approval requirements. Photographs of the nameplate can also help prevent ordering errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10. Does the probe include a factory warranty?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This product includes a 12-month factory warranty, subject to the applicable warranty terms.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330701-330710_277166d5-e9a1-4262-be00-6e9f400c6615.png?v=1793762920\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013945319606,"sku":"330703-000-060-10-11-05","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330703-_2_9ebd2d62-ecf7-458e-81a6-c85ec14a3884.jpg?v=1788768088","url":"https:\/\/www.plcsparehub.com\/products\/330703-000-060-10-11-05-bently-nevada-3300-xl-11mm-metric-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}