{"product_id":"330702-00-30-50-12-05-bently-nevada-3300-xl-11-mm-proximity-probe-fluidloc","title":"330702-00-30-50-12-05 Bently Nevada 3300 XL 11 mm Proximity Probe | FluidLoc","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe 330702-00-30-50-12-05 from Bently Nevada belongs to the 3300 XL 11 mm proximity transducer series engineered for continuous shaft vibration and position monitoring in rotating machinery protection systems.\u003c\/p\u003e\n\u003cp\u003eThis armored FluidLoc configuration is widely applied in steam turbines, centrifugal compressors, API pumps, and gearbox monitoring systems where oil contamination, vibration stress, and long-term signal stability are critical considerations.\u003c\/p\u003e\n\u003cp\u003eCompared with conventional eddy current probes, the 75 Ω triaxial cable structure provides improved EMI resistance and more stable signal transmission in high-noise industrial environments.\u003c\/p\u003e\n\u003ch2\u003eConfiguration Breakdown\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eEngineering Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330702\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Probe with armor\u003c\/td\u003e\n\u003ctd\u003eEnhanced cable protection for vibration-intensive machinery areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n\u003ctd\u003eSuitable for compact probe bracket installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e3.0 in overall case length\u003c\/td\u003e\n\u003ctd\u003eSupports medium-depth mounting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 meter total length\u003c\/td\u003e\n\u003ctd\u003eDesigned exclusively for 5 m Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc connector + FluidLoc cable\u003c\/td\u003e\n\u003ctd\u003eImproves resistance to lubricant ingress and cable contamination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals\u003c\/td\u003e\n\u003ctd\u003eSimplifies international hazardous-area deployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Structure Tree\u003c\/h2\u003e\n\u003cpre\u003e330702-00-30-50-12-05\n├── 3300 XL 11 mm Probe\n├── 1\/2-20 UNF Thread\n├── Armored Construction\n├── 5 Meter Cable System\n│   ├── FluidLoc Technology\n│   ├── FEP Insulation\n│   └── 75 Ω Triaxial Cable\n├── ClickLoc Miniature Connector\n├── AISI 304 Stainless Steel Housing\n├── PPS Probe Tip\n└── Multiple Hazardous Area Approvals\n\u003c\/pre\u003e\n\u003ch2\u003eKey Technical Advantages\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIndustrial Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluidLoc Cable Technology\u003c\/td\u003e\n\u003ctd\u003eReduces oil migration inside the cable structure and improves long-term signal stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmored Probe Design\u003c\/td\u003e\n\u003ctd\u003eProtects the cable against vibration abrasion and mechanical damage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWide Temperature Capability\u003c\/td\u003e\n\u003ctd\u003eSupports operation in turbine enclosures and high-temperature process areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePPS Probe Tip Material\u003c\/td\u003e\n\u003ctd\u003eImproves chemical resistance in refinery and offshore environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClickLoc Connector\u003c\/td\u003e\n\u003ctd\u003eAccelerates replacement during shutdown maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSuitable Equipment \u0026amp; Applications\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eTypical Equipment\u003c\/th\u003e\n\u003cth\u003eApplication Purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil \u0026amp; Gas\u003c\/td\u003e\n\u003ctd\u003eCompressors and turbines\u003c\/td\u003e\n\u003ctd\u003eRadial vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Generation\u003c\/td\u003e\n\u003ctd\u003eSteam turbines\u003c\/td\u003e\n\u003ctd\u003eShaft displacement protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Plants\u003c\/td\u003e\n\u003ctd\u003eAPI process pumps\u003c\/td\u003e\n\u003ctd\u003eBearing condition supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLNG Facilities\u003c\/td\u003e\n\u003ctd\u003eCryogenic compressors\u003c\/td\u003e\n\u003ctd\u003eRotor stability analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaper Mills\u003c\/td\u003e\n\u003ctd\u003eHigh-speed rollers\u003c\/td\u003e\n\u003ctd\u003eMechanical runout monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDiagnostic Capability\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShaft vibration trending\u003c\/li\u003e\n\u003cli\u003eDifferential expansion monitoring\u003c\/li\u003e\n\u003cli\u003eRotor eccentricity analysis\u003c\/li\u003e\n\u003cli\u003eMechanical looseness detection\u003c\/li\u003e\n\u003cli\u003eEarly-stage bearing degradation identification\u003c\/li\u003e\n\u003cli\u003eThrust position supervision\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn actual refinery and turbine installations, FluidLoc cable versions are frequently selected to minimize intermittent vibration spikes caused by lubricant contamination inside conventional probe cable assemblies.\u003c\/p\u003e\n\u003ch2\u003eMechanical \u0026amp; Electrical Specifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread\u003c\/td\u003e\n\u003ctd\u003e1\/2-20 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thread Engagement\u003c\/td\u003e\n\u003ctd\u003e0.750 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 304 SST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial FEP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e5 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Resistance\u003c\/td\u003e\n\u003ctd\u003e7.2 ± 0.8 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e25.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Probe Torque\u003c\/td\u003e\n\u003ctd\u003e15.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Torque\u003c\/td\u003e\n\u003ctd\u003e45.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eGlobal PLC Spare HUB's Insight\u003c\/h2\u003e\n\u003cp\u003eFrom field replacement experience in turbine cabinets and compressor skids, the armored FluidLoc version demonstrates better long-term survivability in high-oil-mist environments compared with standard cable configurations.\u003c\/p\u003e\n\u003cp\u003eOne installation issue commonly overlooked is excessive connector torque. Over-tightening miniature ClickLoc connectors may distort center pin alignment and create unstable gap voltage readings that appear as false vibration alarms.\u003c\/p\u003e\n\u003cp\u003eFor improved signal integrity, avoid routing probe cables parallel to VFD power cables and maintain proper cable bend radius throughout the installation path.\u003c\/p\u003e\n\u003ch2\u003eModel Comparison \u0026amp; Selection Guidance\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eMain Difference\u003c\/th\u003e\n\u003cth\u003eRecommended Use\u003c\/th\u003e\n\u003cth\u003eTechnical Recommendation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330702-00-30-50-11-05\"\u003e 330702-00-30-50-11-05 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard connector option\u003c\/td\u003e\n\u003ctd\u003eGeneral machinery monitoring\u003c\/td\u003e\n\u003ctd\u003eSuitable for clean indoor equipment rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330702-00-10-90-02-00\"\u003e 330702-00-10-90-02-00 \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e9 meter cable configuration\u003c\/td\u003e\n\u003ctd\u003eRemote cabinet installations\u003c\/td\u003e\n\u003ctd\u003eRecommended where long routing distance is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e330702-00-30-50-12-05\u003c\/td\u003e\n\u003ctd\u003eFluidLoc armored construction\u003c\/td\u003e\n\u003ctd\u003eTurbines and critical compressors\u003c\/td\u003e\n\u003ctd\u003eRecommended for oil-contaminated and high-vibration environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWarranty \u0026amp; Shipping\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eService Item\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 Months Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Methods\u003c\/td\u003e\n\u003ctd\u003eFedEx \/ UPS \/ DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eIndustrial anti-static protective packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTesting Status\u003c\/td\u003e\n\u003ctd\u003eTested before shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Supply\u003c\/td\u003e\n\u003ctd\u003eWorldwide delivery support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eProfessional FAQ\u003c\/h2\u003e\n\u003ch3\u003e1. Why does the probe sometimes generate unstable gap voltage after startup?\u003c\/h3\u003e\n\u003cp\u003eThis is commonly caused by improper grounding, cable contamination, or routing too close to high-current motor cables. In turbine retrofit projects, EMI interference is a frequent source of unstable readings.\u003c\/p\u003e\n\u003ch3\u003e2. Is armored construction necessary for indoor machinery rooms?\u003c\/h3\u003e\n\u003cp\u003eNot always, but armored versions significantly reduce cable fatigue failures near vibrating cable trays and maintenance access areas.\u003c\/p\u003e\n\u003ch3\u003e3. Can this probe be mixed with non-5-meter Proximitor systems?\u003c\/h3\u003e\n\u003cp\u003eNo. The total transducer system length must remain matched to maintain calibration accuracy and proper vibration scaling.\u003c\/p\u003e\n\u003ch3\u003e4. What installation mistake most frequently shortens probe service life?\u003c\/h3\u003e\n\u003cp\u003eExcessive cable bending near the probe exit is a major cause of premature signal degradation and intermittent vibration alarms.\u003c\/p\u003e\n\u003ch3\u003e5. How should buyers choose between standard and FluidLoc versions?\u003c\/h3\u003e\n\u003cp\u003eFluidLoc versions are strongly recommended for oil mist, lubrication vapor, offshore, and refinery environments where long-term cable contamination can affect signal reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330702_2.png?v=1779178503\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014024618166,"sku":"330702-00-30-50-12-05","price":240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently330702_14.jpg?v=1779178526","url":"https:\/\/www.plcsparehub.com\/products\/330702-00-30-50-12-05-bently-nevada-3300-xl-11-mm-proximity-probe-fluidloc","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}