{"product_id":"330500-05-04-bently-nevada-330500-piezo-velocity-sensor-csa-atex","title":"330500-05-04 Bently Nevada 330500 Piezo-Velocity Sensor | CSA ATEX","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Vibration Measurement Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003eBently Nevada 330500-05-04\u003c\/span\u003e\u003c\/strong\u003e is a Velomitor Piezo-velocity Sensor designed for industrial machinery vibration monitoring.\u003c\/p\u003e\n\u003cp\u003eIt uses piezoelectric sensing technology to measure machine casing vibration velocity. The sensor converts mechanical vibration into an electrical output for compatible monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eIts measurement range reaches \u003cstrong\u003e1,270 mm\/s peak (50 in\/s peak)\u003c\/strong\u003e. Its frequency response covers \u003cstrong\u003e4.5 Hz to 5 kHz\u003c\/strong\u003e. These characteristics support vibration monitoring across a wide range of rotating machinery applications.\u003c\/p\u003e\n\u003cp\u003eThe sensor features a hermetically sealed 316L stainless steel housing. Its isolated case reduces unwanted grounding interactions. A two-pin MIL-C-5015 connector provides the electrical interface.\u003c\/p\u003e\n\u003cp\u003eManufactured in the \u003cstrong\u003eUSA\u003c\/strong\u003e, this sensor offers CSA and ATEX approval options. It also supports specified hazardous-area installations and demanding industrial environments.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Technology:\u003c\/strong\u003e Piezoelectric velocity sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Sensitivity:\u003c\/strong\u003e 3.94 mV\/mm\/s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 4.5 Hz to 5 kHz at ±3 dB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVelocity Range:\u003c\/strong\u003e 1,270 mm\/s peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Hermetically sealed 316L stainless steel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -55°C to +121°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-Area Approvals:\u003c\/strong\u003e CSA and ATEX options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown | Model and Suffix Identification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCorrect configuration identification is essential when selecting Bently Nevada vibration sensors. The following breakdown explains the supplied product designation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eEngineering Interpretation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330500\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eVelomitor Piezo-velocity Sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Thread Option\u003c\/td\u003e\n\u003ctd\u003eUnavailable for the 330500 model.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals, including CSA and ATEX.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Configuration Notice:\u003c\/strong\u003e The supplied part number is \u003cstrong\u003e330500-05-04\u003c\/strong\u003e. However, the -05 mounting option is explicitly unavailable for the 330500 model.\u003c\/p\u003e\n\u003cp\u003eFor applications requiring \u003cstrong\u003e1\/4-18 NPT mounting\u003c\/strong\u003e, the manufacturer specifies model \u003cstrong\u003e330525\u003c\/strong\u003e. Verify the actual nameplate and ordering configuration before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification Tree:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0070c0;\"\u003e330500\u003c\/span\u003e — Velomitor Piezo-velocity Sensor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-05: Unavailable for model 330500.\u003c\/li\u003e\n\u003cli\u003e1\/4-18 NPT requirement: Refer to model 330525.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Configuration\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e-04: Multiple approvals, including CSA and ATEX.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications | Electrical and Measurement Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following electrical parameters use the manufacturer's stated reference conditions. Unless otherwise indicated, specifications apply at \u003cstrong\u003e+20°C to +30°C\u003c\/strong\u003e and \u003cstrong\u003e100 Hz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330500-05-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330500\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eVelomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePiezo-velocity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric velocity sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e3.94 mV\/mm\/s (100 mV\/in\/s), ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response, ±3 dB\u003c\/td\u003e\n\u003ctd\u003e4.5 Hz to 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response, ±0.9 dB\u003c\/td\u003e\n\u003ctd\u003e6.0 Hz to 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Range\u003c\/td\u003e\n\u003ctd\u003e1,270 mm\/s (50 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e±2% up to 152 mm\/s (6 in\/s) peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 5% of sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensitivity\u003c\/td\u003e\n\u003ctd\u003e-14% to +7.5% typical over operating temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounted Resonant Frequency\u003c\/td\u003e\n\u003ctd\u003eGreater than 12 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Bias Voltage\u003c\/td\u003e\n\u003ctd\u003e-12 ±3.0 VDC, referenced to Pin A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Output Impedance\u003c\/td\u003e\n\u003ctd\u003eLess than 2,400 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadband Noise Floor\u003c\/td\u003e\n\u003ctd\u003e0.004 mm\/s RMS nominal, 4.5 Hz to 5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Strain Sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.005 in\/s\/mstrain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Field Susceptibility\u003c\/td\u003e\n\u003ctd\u003eLess than 51 min\/s\/gauss at 50 gauss, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding\u003c\/td\u003e\n\u003ctd\u003eCase isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to +121°C (-67°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous-Area Temperature Class\u003c\/td\u003e\n\u003ctd\u003eT4 at -40°C ≤ Ta ≤ +100°C for specified approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Survivability\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 100%, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Construction\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003e316L stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter\u003c\/td\u003e\n\u003ctd\u003e25.3 mm (0.995 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e63.2 mm (2.49 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Weight\u003c\/td\u003e\n\u003ctd\u003e142 g (5.0 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Construction\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed, 316L stainless steel shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Mounting Torque\u003c\/td\u003e\n\u003ctd\u003e32–46 kg·cm (24–40 in-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connection and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe sensor provides a two-pin electrical interface. Correct polarity is essential when connecting the sensor to the monitoring system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnection Item\u003c\/th\u003e\n\u003cth\u003eTechnical Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin A\u003c\/td\u003e\n\u003ctd\u003ePositive relative to Pin B when the case moves toward the connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin B\u003c\/td\u003e\n\u003ctd\u003eReference polarity terminal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Bias\u003c\/td\u003e\n\u003ctd\u003e-12 ±3.0 VDC, referenced to Pin A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Grounding\u003c\/td\u003e\n\u003ctd\u003eElectrically isolated case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Polarity:\u003c\/strong\u003e When the sensor case moves toward the connector, Pin A becomes positive relative to Pin B.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified polarity when wiring the sensor. Incorrect polarity can affect the vibration signal interpretation.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCable Selection and Signal Transmission\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCable capacitance and length influence signal transmission. Select the cable according to the installation distance and vibration frequency requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Cable Length\u003c\/td\u003e\n\u003ctd\u003e208 ft (63 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Specified Cable Length\u003c\/td\u003e\n\u003ctd\u003e305 m (1,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified Cable Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02173006\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Length Conditions\u003c\/td\u003e\n\u003ctd\u003e50 g maximum vibration, 10 kHz frequency, 200 pF\/m cable capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manufacturer specifies up to 305 m of cable part number \u003cstrong\u003e02173006\u003c\/strong\u003e without signal degradation.\u003c\/p\u003e\n\u003cp\u003eThe 63 m recommendation uses different stated operating assumptions. Do not treat both figures as identical installation limits.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous-Area Approvals and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330500\u003c\/strong\u003e sensor has specified hazardous-area protection classifications. Installation must follow the applicable certification conditions and manufacturer drawing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection Type\u003c\/th\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Intrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eAEx ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass I, Division 1\u003c\/td\u003e\n\u003ctd\u003eGroups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass II\u003c\/td\u003e\n\u003ctd\u003eGroups E, F, and G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003ctd\u003eSpecified classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Incendive Protection\u003c\/td\u003e\n\u003ctd\u003eEx nL IIC T4 \/ AEx nA IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass I, Division 2\u003c\/td\u003e\n\u003ctd\u003eGroups A, B, C, and D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Classification\u003c\/td\u003e\n\u003ctd\u003eT4 at -40°C ≤ Ta ≤ +100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Drawing\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e167537\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eAdditional Compliance Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Multiple agency approval option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Multiple agency approval option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e Directive 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDNV:\u003c\/strong\u003e Maritime classification rules for ships, high-speed craft, light craft, and offshore applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Notice:\u003c\/strong\u003e Use the applicable control drawing 167537 for hazardous-area installation. Verify the exact approval markings and installation conditions before commissioning.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330500_2.png?v=1787033119\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013933359286,"sku":"330500-05-04","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330500_1_a7820caf-0bdb-4c51-82e1-5d32ef5bb953.jpg?v=1795060832","url":"https:\/\/www.plcsparehub.com\/products\/330500-05-04-bently-nevada-330500-piezo-velocity-sensor-csa-atex","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}