{"product_id":"330303-006-50-90-01-00-bently-nevada-high-temp-proximity-probe-series","title":"330303-006-50-90-01-00 Bently Nevada High Temp Proximity Probe Series","description":"\u003ch3\u003eProduct Introduction\u003c\/h3\u003e\n\u003cp\u003eWelcome to Global PLC Spare HUB's Insight for the \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e \u003cstrong\u003e3300 XL High Temperature Probe, Smooth Case\u003c\/strong\u003e. This specialized vibration sensor is engineered for extreme thermal environments where standard probes degrade. Operating reliably up to +350 degrees Celsius, this \u003cstrong\u003e3300 XL High Temperature Series\u003c\/strong\u003e probe utilizes a robust ceramic tip and AISI 316L stainless steel housing. Global PLC Spare HUB Review notes that deploying high-temperature transducers directly inside heated machinery prevents catastrophic failure by maintaining accurate dynamic gap measurements under severe heat loads.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown \u0026amp; Suffix Tree Structure\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e part number expands into specific factory configuration nodes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong\u003e330303\u003c\/strong\u003e — 3300 XL High Temperature Proximity Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length Option:\u003c\/strong\u003e \u003cstrong\u003e006\u003c\/strong\u003e — 0.6 inch smooth case construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardline Length Option:\u003c\/strong\u003e \u003cstrong\u003e50\u003c\/strong\u003e — 5.0 metres (16.4 feet) integral hardline cable length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Option:\u003c\/strong\u003e \u003cstrong\u003e90\u003c\/strong\u003e — 9.0 metres (30 feet) total system length including matched extension cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension Cable Armor Option:\u003c\/strong\u003e \u003cstrong\u003e01\u003c\/strong\u003e — Equipped with mechanical stainless steel protective armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option:\u003c\/strong\u003e \u003cstrong\u003e00\u003c\/strong\u003e — Standard non-approved commercial configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnical Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \u0026amp; Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3300 XL High Temperature Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal over 4.0 mm linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-34 degrees Celsius to +350 degrees Celsius (-30°F to +662°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 6 kHz (+0, -3 dB typical with up to 305m field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTip \u0026amp; Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic probe tip with AISI 316L stainless steel smooth case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target \u0026amp; Shaft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.5 mm flat target diameter; 152 mm minimum shaft diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Comparison \u0026amp; Engineering Selection Guide\u003c\/h3\u003e\n\u003cp\u003eWhen engineering vibration monitoring loops for extreme thermal applications, technicians frequently evaluate the \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e against alternative hardline configurations such as the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330303-006-20-90-01-00-bently-nevada-high-temp-proximity-probe\"\u003e330303-006-20-90-01-00\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eHardline Length Analysis:\u003c\/strong\u003e The model features a 5.0-metre hardline cable option, providing extended physical routing through thick thermal insulation jackets before transitioning to standard extension cabling. In contrast, alternative units like the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330303-006-20-90-01-00-bently-nevada-high-temp-proximity-probe\"\u003e330303-006-20-90-01-00\u003c\/a\u003e utilize a shorter 2.0-metre hardline section.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSelection Recommendation:\u003c\/strong\u003e Specify the \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e when routing cable runs through deep insulation layers on large steam turbines to keep connectors outside extreme heat zones. Select shorter hardline variants only when physical clearance constraints restrict excess cable coiling near the machine casing.\u003c\/div\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv\u003eSmooth case mounting requires precision clamp fixtures to secure the 0.6-inch probe body without crushing the stainless steel sleeve.\u003c\/div\u003e\n\u003cdiv\u003eEnsure the hardline cable is anchored securely with P-clips to prevent work-hardening caused by high-amplitude machinery vibration.\u003c\/div\u003e\n\u003cdiv\u003eVerify that the system total length matches the 9.0-metre calibration requirement to preserve signal linearity.\u003c\/div\u003e\n\u003cdiv\u003eKeep the ceramic tip aligned squarely against a minimum 30.5 mm flat target surface.\u003c\/div\u003e\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cdiv\u003eThe 3.94 V\/mm scale factor simplifies scaling adjustments on machinery protection monitor channels.\u003c\/div\u003e\n\u003cdiv\u003eStainless steel armor protects vulnerable hardline sections against accidental tool strikes during outage maintenance.\u003c\/div\u003e\n\u003cdiv\u003eDC resistance checks across center and outer conductors verify cable integrity prior to initial system startup.\u003c\/div\u003e\n\u003ch3\u003eCompatibility \u0026amp; Integration\u003c\/h3\u003e\n\u003cdiv\u003eFully compatible with specialized high-temperature 3300 XL Proximitor sensors and matching extension cables.\u003c\/div\u003e\n\u003cdiv\u003eIntegrates smoothly into standard rack-based vibration monitors accepting 100 mV\/mil transducer inputs.\u003c\/div\u003e\n\u003ch3\u003eCertification Information\u003c\/h3\u003e\n\u003cdiv\u003eSupplied with standard commercial non-hazardous documentation per option code 00.\u003c\/div\u003e\n\u003cdiv\u003eDesigned to meet rigorous electrical noise immunity standards in heavy industrial power plants.\u003c\/div\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Warranty\u003c\/h3\u003e\n\u003cdiv\u003eOne \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330303-006-50-90-01-00\u003c\/strong\u003e \u003cstrong\u003e3300 XL High Temperature Probe\u003c\/strong\u003e with 5m hardline and armor.\u003c\/div\u003e\n\u003cdiv\u003eMatched 9-metre system extension cable and connector protection sleeves.\u003c\/div\u003e\n\u003cdiv\u003eBacked by a full \u003cstrong\u003e12-month warranty\u003c\/strong\u003e from the invoice date.\u003c\/div\u003e\n\u003ch3\u003eShipping and Logistics\u003c\/h3\u003e\n\u003cdiv\u003eRapid fulfillment within \u003cstrong\u003e24-48 hours\u003c\/strong\u003e from confirmed order entry.\u003c\/div\u003e\n\u003cdiv\u003eSecure global express transit handled via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/div\u003e\n\u003cdiv\u003ePacked in rugged industrial containers to prevent shipping damage.\u003c\/div\u003e\n\u003ch3\u003eTypical Applications and Diagnostic Capability\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eApplication 1:\u003c\/strong\u003e Radial vibration monitoring on heavy-duty industrial steam turbines operating above standard temperature thresholds.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eApplication 2:\u003c\/strong\u003e Shaft position tracking inside high-temperature refinery process compressors and gas expanders.\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDiagnostic Capability:\u003c\/strong\u003e Identifies high-temperature rotor thermal bow, unbalance, rubs, and bearing instabilities before catastrophic seizure occurs.\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the high-temperature model utilize a ceramic tip instead of standard polyphenylene sulfide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCeramic material withstands continuous operating temperatures up to +350 degrees Celsius without structural softening or losing dimensional stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does extending the hardline cable length to 5.0 metres affect signal output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system is specifically calibrated to account for signal attenuation, maintaining reliable frequency response up to 6 kHz across designated total lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat field diagnostic step confirms a failing hardline cable in high-heat zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the probe resistance; a reading deviating significantly from the nominal 8.11 ohms indicates internal conductor damage or thermal breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I interchange standard 3300 XL extension cables with the 330303-006-50-90-01-00 setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, high-temperature systems require matched electrical components and specific cable lengths to preserve the calibrated 3.94 V\/mm incremental scale factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the best practice for securing smooth case probes in high-vibration gas turbines?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse high-clamp-force split-clamp brackets lined with compatible anti-rotation material to prevent axial slippage during thermal expansion cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330303.png?v=1779872473\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013973139638,"sku":"330303-006-50-90-01-00","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330303_68417466-330d-419d-a2d4-dc09c305ee31.jpg?v=1784786651","url":"https:\/\/www.plcsparehub.com\/products\/330303-006-50-90-01-00-bently-nevada-high-temp-proximity-probe-series","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}