{"product_id":"330302-000-011-10-90-00-05-bently-nevada-3300-high-temperature-proximity-probe","title":"330302-000-011-10-90-00-05 Bently Nevada 3300 High Temperature Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eTransducer Architecture \u0026amp; Operational Purpose\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 330302-000-011-10-90-00-05\u003c\/strong\u003e is a high-temperature eddy current proximity transducer engineered within the \u003cstrong style=\"color: #0056b3;\"\u003e3300 High Temperature Proximity System (HTPS)\u003c\/strong\u003e. Manufactured in the U.S.A. with a ceramic sensing tip and AISI 316L stainless steel case, this probe measures shaft vibration and axial position in extreme thermal zones up to +350°C (+662°F). Its integrated 1.0-metre hardline cable and matched 9.0-metre system length eliminate external in-line connectors inside hot turbine or compressor casings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Breakdown \u0026amp; Configuration Tree\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e330302-000-011-10-90-00-05\u003c\/strong\u003e catalog code specifies exact mechanical dimensions, cable lengths, and hazardous area certifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e330302\u003c\/strong\u003e — 3300 High Temperature Proximity Probe (M14 x 1.5 thread metric variant)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Length (-000):\u003c\/strong\u003e 0 mm (Fully threaded case to sensing tip)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length (-011):\u003c\/strong\u003e 11 mm total probe body length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardline Length (-10):\u003c\/strong\u003e 1.0 metre (3.3 feet) integral mineral-insulated hardline cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Length (-90):\u003c\/strong\u003e 9.0 metres (30 feet), inclusive of factory-matched extension cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension Cable Armor (-00):\u003c\/strong\u003e Without stainless steel armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval (-05):\u003c\/strong\u003e Multiple hazardous location approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectromechanical \u0026amp; Thermal Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePerformance Metric\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer \u0026amp; Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e (Made in U.S.A.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Ordering Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003e330302-000-011-10-90-00-05\u003c\/strong\u003e (\u003cstrong style=\"color: #0056b3;\"\u003e3300 HTPS\u003c\/strong\u003e Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \u0026amp; Storage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-34°C to +350°C (-30°F to +662°F) continuous probe rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils) calibrated linear span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) ±9.65% at ambient (including interchangeability error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than ±78 μm (±3.1 mils) at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtended Temp System Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22°C to +350°C: ISF within ±30% of 3.94 V\/mm; DSL within ±0.51 mm (±20 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 6 kHz (+0, -3 dB typical with up to 305 m \/ 1000 ft of field wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (R\u003csub\u003ePROBE\u003c\/sub\u003e)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.06 Ω nominal (1.0 m hardline center-to-outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Target Geometry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat target: 30.5 mm (1.2 in) diameter | Shaft: 152 mm (6.0 in) minimum diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWetted \u0026amp; Structural Materials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic sensing tip; AISI 316L stainless steel (SST) case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Mass Calculation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117 g\/m (1.26 oz\/ft) hardline cable + 12 g\/cm (1.07 oz\/in) probe case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation \u0026amp; Commissioning Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Target Surface Dimensions:\u003c\/strong\u003e Verify shaft diameter meets or exceeds 152 mm (6.0 in) to prevent side-view eddy current field distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute Integral Hardline Carefully:\u003c\/strong\u003e Bend the 1.0 m mineral-insulated hardline smoothly out of the +350°C hot zone before transitioning to the included extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevent Hardline Kinking:\u003c\/strong\u003e Support the rigid hardline with high-temperature stainless steel P-clips to prevent fatigue fractures from casing vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify DC Resistance Before Gap Setting:\u003c\/strong\u003e Measure 5.06 Ω across the probe connector to confirm intact internal coil continuity prior to setting the mechanical gap.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Operational Boundaries\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Pairing:\u003c\/strong\u003e Requires a matched \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 3300 HTPS\u003c\/strong\u003e 9.0-metre Proximitor sensor calibrated to the 3.94 V\/mm (100 mV\/mil) scale factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Zone Separation:\u003c\/strong\u003e Keep the extension cable junction and Proximitor electronics outside the +350°C enclosure within their respective lower temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 330302-000-011-10-90-00-05\u003c\/strong\u003e High Temperature Proximity Probe (11 mm case, 1.0 m hardline)\u003c\/li\u003e\n\u003cli\u003e1 × Factory-matched High-Temperature Extension Cable (completing the 9.0 m total system length)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does this probe specify a 152 mm (6.0 in) minimum shaft diameter compared to standard 8 mm probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The larger ceramic sensing coil generates a wider electromagnetic field to achieve a 4.0 mm (160 mil) linear range; smaller shafts curve away too sharply and skew the incremental scale factor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I shorten or splice the 1.0-metre hardline cable if it is too long for my turbine bearing housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Never cut or splice the mineral-insulated hardline, as its 5.06 Ω impedance and distributed capacitance are tuned to the 9.0-metre Proximitor resonant circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How should engineers interpret the ±30% ISF tolerance across the +22°C to +350°C operating span?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Extreme heat alters coil resistance and target permeability; this probe is engineered primarily for dynamic relative vibration measurements at elevated temperatures rather than precision cold-to-hot absolute thermal growth tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What precautionary steps are required when installing the unarmored (-00) extension cable in industrial plants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Because option -00 omits stainless steel armor, route the extension cable inside rigid metallic conduit once it exits the high-temperature machine casing to prevent mechanical abrasion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How do I verify probe integrity during a turbine outage without removing the transducer from its mount?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: Disconnect the extension cable at the Proximitor and measure center-to-shield DC resistance; readings deviating significantly from 5.06 Ω (plus extension cable resistance) indicate open coils or moisture ingress in the hardline.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330301_330302_d5d69828-93d8-48b9-b38f-787cdbb96b34.png?v=1788493260\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013972877494,"sku":"330302-000-011-10-90-00-05","price":113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330302_1_4e7b3a44-b3fd-4d8a-9aab-9fd0d9474109.jpg?v=1789009417","url":"https:\/\/www.plcsparehub.com\/products\/330302-000-011-10-90-00-05-bently-nevada-3300-high-temperature-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}