{"product_id":"330191-00-70-05-00-bently-nevada-3300-xl-etr-probe-robust-8-mm-sensor","title":"330191-00-70-05-00 Bently Nevada 3300 XL ETR Probe | Robust 8 mm Sensor","description":"\u003ch3\u003e\u003cb\u003eBently Nevada 330191-00-70-05-00 | 3300 XL 8 mm ETR Proximity Probe\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #d97706;\"\u003e330191-00-70-05-00\u003c\/span\u003e\u003c\/b\u003e is a Bently Nevada \u003cb\u003e3300 XL 8 mm Extended Temperature Range (ETR) proximity probe\u003c\/b\u003e. It provides non-contact displacement sensing for rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis configuration uses a \u003cb\u003e3\/8-24 UNF mounting thread\u003c\/b\u003e, a \u003cb\u003e7-inch overall case\u003c\/b\u003e, and a \u003cb\u003e0.5-meter probe cable\u003c\/b\u003e. Its unarmored construction suits installations that require compact probe mounting and a defined cable route.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm design uses a molded PPS probe tip and a robust stainless-steel case. TipLoc and CableLoc construction improve the mechanical connection between the probe tip, body, and cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAt a Glance | Product Identity\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct family\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eExtended Temperature Range (ETR) proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePart number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e\u003cspan style=\"color: #d97706;\"\u003e330191-00-70-05-00\u003c\/span\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement principle\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEddy-current, non-contact displacement sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCondition\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNew and original in factory packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWarranty\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months, subject to applicable warranty terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eConfiguration Breakdown | Decode the Part Number\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eUse this suffix map to identify the requested mechanical configuration.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCode\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eConfiguration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEngineering interpretation\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e330191\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR probe\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF thread; supplied without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e-00\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003eMinimum unthreaded length: 0.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e-70\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e7 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e-05\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal probe length\u003c\/td\u003e\n\u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e-00\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003eApproval not required for this ordering configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eConfiguration check:\u003c\/b\u003e The supplied ordering information identifies the mounting thread, case length, probe length, and approval option. Confirm the delivered cable construction and temperature rating against the unit's markings and documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications | Mechanical and Electrical\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e330191-00-70-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSeries\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eThread\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum thread engagement\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.563 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUnthreaded length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOverall case length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal probe length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (1.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe tip material\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe case material\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe nominal DC resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.45 ± 0.50 Ω, center conductor to outer conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe cable construction\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ω triaxial cable; standard FEP or extended-temperature PFA cable options exist. Verify the supplied option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe case-to-lead tensile rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lbf), maximum rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe lead-to-extension connector tensile rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e270 N (60 lbf), maximum rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector material\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum connector torque\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.565 N·m (5 in·lbf)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProbe sealing\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eViton® O-ring seals differential pressure between probe tip and case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eMeasurement Performance and System Requirements\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe probe operates within a complete 3300 XL measurement chain. Confirm the matched Proximitor Sensor, extension cable, monitor, and target configuration before commissioning.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower supply requirement\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 to -26 Vdc for nonincendive installation; -23 to -26 Vdc with barriers, as specified for the applicable system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaximum power consumption\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e12 mA, per supplied system specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSupply sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV output change per volt of input change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOutput resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinear range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eVerify against the matched 3300 XL 8 mm ETR system specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eFrequency response\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eVerify against the applicable probe and Proximitor Sensor system response curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eScale factor \/ sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUse the matched system calibration data. The supplied product information does not state a numeric value for this specific ordering configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eLinearity and resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm using the applicable system specification and monitor channel configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e Do not apply the power-supply figures as standalone probe power requirements. They describe the associated measurement electronics and installation conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTemperature Classification | Select for the Actual Environment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied temperature schedule lists different ambient limits by temperature classification. The applicable rating depends on the approved installation and complete system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eClassification\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eProbe ambient temperature range for EPL Ga\/Gc\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT1\u003c\/td\u003e\n\u003ctd\u003e-55°C to +232°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT2\u003c\/td\u003e\n\u003ctd\u003e-55°C to +177°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT3\u003c\/td\u003e\n\u003ctd\u003e-55°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003ctd\u003e-55°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT5\u003c\/td\u003e\n\u003ctd\u003e-55°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe supplied EPL Dc schedule lists separate maximum surface-temperature classifications. Verify the exact marking and certification documentation before applying these values.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSelection guidance:\u003c\/b\u003e Check the temperature at the probe installation point, not only the machinery's general operating temperature. Confirm the cable, connector, Proximitor Sensor, and hazardous-area approvals also meet the application limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eInstallation | Mounting and Cable Handling\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the 3\/8-24 UNF mounting thread and available probe clearance.\u003c\/li\u003e\n\u003cli\u003eKeep thread engagement within the specified 0.563-inch maximum.\u003c\/li\u003e\n\u003cli\u003eSet the probe gap according to the matched Proximitor Sensor instructions.\u003c\/li\u003e\n\u003cli\u003eRoute the cable away from moving parts, sharp edges, and hot surfaces.\u003c\/li\u003e\n\u003cli\u003ePrevent connector strain. Observe the specified maximum connector torque.\u003c\/li\u003e\n\u003cli\u003eUse the correct extension cable and monitor configuration for the complete electrical length.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's grounding, shielding, and hazardous-area installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not pressure-test the probe without an approved procedure. The manufacturer states that probes are not pressure-tested before shipment.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility | Replacement and System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e3300 XL 8 mm ETR probe\u003c\/b\u003e requires compatible Bently Nevada proximity monitoring components. Verify the complete system before ordering a replacement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProximitor Sensor:\u003c\/b\u003e Confirm the sensor supports the 3300 XL 8 mm ETR probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExtension cable:\u003c\/b\u003e Match the cable type and total electrical length to the existing installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMonitor:\u003c\/b\u003e Verify input compatibility, channel settings, and calibration requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical mounting:\u003c\/b\u003e Match the thread, case length, and installation clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHazardous-area installation:\u003c\/b\u003e Confirm approval markings and the required barriers or isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA similar probe family name does not guarantee an interchangeable installation. Confirm the complete part number and system configuration before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlternative Selection | Compare the Installed Configuration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eReview the linked alternative before choosing a replacement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSelection item\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequested model\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAlternative model\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e330191-00-70-05-00\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330191-00-08-15-05-3300-xl-etr-probe\"\u003e\u003cb\u003e330191-00-08-15-05\u003c\/b\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm ETR\u003c\/td\u003e\n\u003ctd\u003e3300 XL ETR probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003ctd\u003eVerify against the complete manufacturer configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase length\u003c\/td\u003e\n\u003ctd\u003e7 in\u003c\/td\u003e\n\u003ctd\u003eVerify the alternative's dimensional option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003ctd\u003eVerify the alternative's total length option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval option\u003c\/td\u003e\n\u003ctd\u003e00: approval not required\u003c\/td\u003e\n\u003ctd\u003eVerify the alternative's approval markings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eTechnical recommendation:\u003c\/b\u003e The linked alternative has a different suffix configuration. Do not treat it as a drop-in replacement without checking its dimensions, cable length, connector arrangement, and approvals.\u003c\/p\u003e\n\u003cp\u003eFor a maintenance replacement, use the original probe label and installation drawing as the primary references. If the installed dimensions or cable route differ, confirm the mechanical fit before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTypical Equipment and Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSteam turbines:\u003c\/b\u003e Radial shaft vibration and displacement monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGas turbines:\u003c\/b\u003e Shaft movement monitoring within compatible machinery protection systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompressors:\u003c\/b\u003e Non-contact shaft measurement for vibration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCentrifugal pumps:\u003c\/b\u003e Shaft vibration and position measurement where the target geometry supports proximity sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial rotating equipment:\u003c\/b\u003e Condition monitoring in installations that require the specified ETR probe configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight | Diagnostic Practice\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen a proximity channel behaves unexpectedly, check the probe installation and measurement chain before changing monitor settings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eObserved condition\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRecommended diagnostic checks\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGap voltage differs from the expected value\u003c\/td\u003e\n\u003ctd\u003eInspect probe clearance, mounting position, target surface, and sensor compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration signal becomes intermittent\u003c\/td\u003e\n\u003ctd\u003eInspect the connector, cable strain, shielding, and possible insulation damage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings change after a probe replacement\u003c\/td\u003e\n\u003ctd\u003eCompare the part numbers, probe lengths, extension cable, calibration, and target geometry.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected signal behavior at elevated temperature\u003c\/td\u003e\n\u003ctd\u003eVerify the actual probe temperature, cable rating, connector condition, and system temperature limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnusual vibration trend without a clear mechanical change\u003c\/td\u003e\n\u003ctd\u003eReview baseline data and check installation integrity before attributing the trend to machinery deterioration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eField example:\u003c\/b\u003e A turbine channel shows a different vibration level after maintenance. An engineer should first verify the installed gap and probe model. The engineer should then inspect cable connections and compare the channel's calibration. This process separates installation changes from possible machinery faults.\u003c\/p\u003e\n\u003cp\u003eThese diagnostic steps support field troubleshooting. They do not replace site procedures, alarm limits, or manufacturer-approved machinery protection practices.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCertification and Ordering Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe requested suffix \u003cb\u003e00\u003c\/b\u003e identifies an agency approval option that is not required.\u003c\/li\u003e\n\u003cli\u003eDo not assume this exact configuration has approval for a classified location.\u003c\/li\u003e\n\u003cli\u003eCheck the delivered product markings and certificates for the intended installation.\u003c\/li\u003e\n\u003cli\u003eConfirm whether barriers or isolators are required by the system design.\u003c\/li\u003e\n\u003cli\u003eVerify pressure-seal requirements separately. The probe's Viton® O-ring does not establish a pressure-test certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackaging, Warranty, and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProduct condition:\u003c\/b\u003e New and original in factory packing, as stated in the listing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging:\u003c\/b\u003e Protective factory packaging. Confirm additional accessories and documentation with the order.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch estimate:\u003c\/b\u003e 24–48 hours after order confirmation, subject to stock and processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOrder support:\u003c\/b\u003e Global PLC Spare HUB can help verify the part number and application requirements before purchase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e1. What does ETR mean for probe selection?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eETR identifies the extended-temperature-range probe configuration. Check the applicable temperature classification and complete system ratings. Do not select solely by the ETR label.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e2. Does the 0.5-meter probe cable eliminate the need for an extension cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNot necessarily. The correct cable arrangement depends on the complete 3300 XL system and required electrical length. Confirm the matched Proximitor Sensor and extension cable configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e3. Can I install this probe in a high-temperature turbine casing?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFirst establish the actual probe ambient temperature and required temperature classification. Then verify the probe, cable, connector, sensor, and installation approvals. The application's hottest point determines the necessary rating.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e4. What information should I provide when requesting a replacement quotation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete probe part number, installed thread and case dimensions, cable length, connector type, and Proximitor Sensor model. Include the temperature and hazardous-area requirements when applicable.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e5. How can I distinguish a probe fault from a monitor-channel problem?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the probe gap, cable continuity, connector condition, and sensor compatibility first. Compare the channel with its commissioning baseline. Use approved test procedures to isolate components without compromising machinery protection.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330191_330192_330193_330194_32a0fcdf-e50c-4499-9ae9-f976bc7295b5.png?v=1781602048\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013951807670,"sku":"330191-00-70-05-00","price":228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330191_20f4c825-1147-4f9c-9a52-5b22f6c55aa9.jpg?v=1792465407","url":"https:\/\/www.plcsparehub.com\/products\/330191-00-70-05-00-bently-nevada-3300-xl-etr-probe-robust-8-mm-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}