{"product_id":"330190-080-01-00-bently-nevada-etr-extension-cable-stock","title":"330190-080-01-00 Bently Nevada ETR Extension Cable Stock","description":"\u003ch3\u003eExecutive Summary\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190-080-01-00\u003c\/strong\u003e\u003c\/span\u003e is a heavy-duty 8.0-meter armored extension cable engineered for the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 3300 XL Extended Temperature Range (ETR) Series\u003c\/strong\u003e\u003c\/span\u003e. Designed to bridge proximity probes and remote Proximitor sensors, this unit maintains tight impedance matching and signal integrity across extreme operating temperatures reaching up to +260 °C (+500 °F).\u003c\/p\u003e\n\u003cp\u003eFeaturing perfluoroalkoxy (PFA) triaxial insulation and flexible stainless steel armor, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190\u003c\/strong\u003e\u003c\/span\u003e cable protects sensitive high-frequency signal lines against hot mechanical abrasion, hot oil spray, and severe industrial electromagnetic interference (EMI).\u003c\/p\u003e\n\u003ch3\u003eCore Architecture \u0026amp; Insulation Technology\u003c\/h3\u003e\n\u003cp\u003eBuilt upon a specialized 75 Ω triaxial transmission path, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL ETR Cable\u003c\/strong\u003e\u003c\/span\u003e replaces standard FEP dielectric jackets with high-grade PFA insulation. Gold-plated brass or gold-plated beryllium copper connectors ensure low contact resistance and prevent galvanic corrosion in high-vibration applications.\u003c\/p\u003e\n\u003cp\u003eThe outer stainless steel armor casing shields the internal triaxial conductors from mechanical crushing, hot metal debris, and pinch hazards while preserving the minimum required 25.4 mm (1.0 in) bend radius during installation through tight conduit runs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6; width: 30%;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Extended Temperature Range (ETR)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190-080-01-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCable Length \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e8.0 meters (26.2 feet), Armored ETR Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eDielectric Insulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e75 Ω Triaxial, Perfluoroalkoxy (PFA) High-Temp Insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCore Resistance (RCORE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e1.76 ± 0.26 Ω (Center conductor to center conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eJacket Resistance (RJACKET)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e0.53 ± 0.11 Ω (Outer conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eNominal Cable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e2.0 mm (80 mils) when matched with 3300 XL Proximitor \u0026amp; Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eConnector Material \u0026amp; Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eGold-plated brass \/ beryllium copper | Max torque: 0.565 N·m (5 in·lbf)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eCable Mass \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e103 g\/m (1.5 oz\/ft) with flexible stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e-52 °C to +260 °C (-62 °F to +500 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eFunctional Safety Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eSIL 2 certified (HFT = 0) | SIL 3 capable (HFT = 1 architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eEMC Compliance Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #dee2e6;\"\u003eDirective 2014\/30\/EU, EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConfiguration Breakdown \u0026amp; Options Tree\u003c\/h3\u003e\n\u003cp\u003eThe part string \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190-080-01-00\u003c\/strong\u003e\u003c\/span\u003e breaks down into the following design parameters:\u003c\/p\u003e\n\u003cul style=\"list-style-type: none; padding-left: 0;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003e330190\u003c\/strong\u003e - 3300 XL ETR Extension Cable Base Unit\n\u003cul style=\"list-style-type: square; margin-top: 4px; padding-left: 25px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e080\u003c\/strong\u003e [Cable Length Option]: 8.0 meters (26.2 feet) calibrated length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e [Armor Option]: Flexible stainless steel armor over PFA triaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e [Agency Approval Option]: Standard non-certified \/ No specific approval required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment, Applications \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190-080-01-00\u003c\/strong\u003e\u003c\/span\u003e cable assembly connects probes inside harsh turbomachinery casings to remote signal conditioners.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Machinery \u0026amp; Application Scenarios:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine high-pressure (HP) rotor expansion and bearing vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eGas turbine exhaust frame bearing housing displacement setups.\u003c\/li\u003e\n\u003cli\u003eEthylene compressor trains requiring high-temperature, oil-proof signal runs.\u003c\/li\u003e\n\u003cli\u003eHydroelectric generator thrust bearing assemblies exposed to mechanical wear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance Match Stability:\u003c\/strong\u003e Holds strict 75 Ω transmission characteristics to keep Average Scale Factor (ASF) shifts below 3%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Drift Suppression:\u003c\/strong\u003e Prevents signal phase delays in Keyphasor lines over long 8.0-meter spans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Loop Protection:\u003c\/strong\u003e Isolated triaxial shielding eliminates common-mode electrical noise in industrial plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eKeep these field installation guidelines in mind when routing the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190-080-01-00\u003c\/strong\u003e\u003c\/span\u003e in industrial skids:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Connector Torque Control:\u003c\/strong\u003e Gold-plated ClickLoc connectors must be hand-tightened to a maximum torque of 0.565 N·m (5 in·lbf). Over-tightening can deform the delicate center conductor pin sockets, causing intermittent open circuits during machine heat-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Total System Length Calibration:\u003c\/strong\u003e Eddy current proximity transducers are calibrated to operate at a specific total system length (typically 9.0 meters when combining a 1.0 m probe with an 8.0 m cable). Never modify or cut the length of the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190\u003c\/strong\u003e\u003c\/span\u003e cable; shortening the line alters circuit inductance and capacitance, invalidating system scale factor calibration.\u003c\/p\u003e\n\u003ch3\u003eLogistics, Packaging \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuality Protection:\u003c\/strong\u003e Includes full \u003cstrong\u003e12 Months Warranty\u003c\/strong\u003e coverage against manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Order Fulfillment:\u003c\/strong\u003e Stock dispatches within 24 to 48 hours from order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Express Courier Delivery:\u003c\/strong\u003e Tracked international express shipping via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, or \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective Packaging:\u003c\/strong\u003e Coiled using large-radius support and fitted with protective dust caps over both connector ends.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide \u0026amp; Technical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Guide: How do I determine if I need an ETR cable like the 330190 instead of a standard 330130 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose the ETR \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330190\u003c\/strong\u003e\u003c\/span\u003e cable when routing through ambient environments exceeding +177 °C (+350 °F). The PFA insulation on the ETR version operates safely up to +260 °C (+500 °F), whereas standard FEP cables fail above +177 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum recommended torque when mating coaxial cable connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply a maximum torque of 0.565 N·m (5 in·lbf). Always use calibrated connector torque wrenches or hand-tighten until the internal click latch engages securely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I interchange 3300 XL 8mm extension cables with older non-XL 3300 components?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. 3300 XL 8mm components are physically and electrically interchangeable with non-XL 3300 5mm and 8mm components, provided you respect the 25.4 mm (1.0 inch) minimum bend radius.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the flexible stainless steel armor ground the extension cable shield?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The stainless steel armor provides mechanical protection and is electrically isolated from the internal triaxial signal shield to prevent ground loop noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I test cable signal integrity before powering up the system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure DC resistance across the center conductor pin to pin (RCORE target: 1.76 ± 0.26 Ω) and outer jacket to outer jacket (RJACKET target: 0.53 ± 0.11 Ω) using a calibrated digital multimeter.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330190.png?v=1788158814\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013972582582,"sku":"330190-080-01-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330190-070-01-CN.jpg?v=1788158842","url":"https:\/\/www.plcsparehub.com\/products\/330190-080-01-00-bently-nevada-etr-extension-cable-stock","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}