{"product_id":"330185-02-3300-xl-precision-micrometer-bently-nevada-calibrator","title":"330185-02 3300 XL Precision Micrometer Bently Nevada Calibrator","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330185-02\u003c\/strong\u003e is a specialized precision calibration instrument manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e within the \u003cstrong\u003e3300 XL\u003c\/strong\u003e series. Designed for metrology and condition monitoring quality assurance, this device is engineered to perform strict acceptance testing on proximity transducer systems. By utilizing a high-precision AISI 4140 alloy steel target button driven in exact increments, it simulates rotating shaft displacement to verify Average Scale Factor (ASF), Incremental Scale Factor (ISF), and Deviation from Straight Line (DSL) against API 670 standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number \u0026amp; Configuration Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong\u003e330185\u003c\/strong\u003e (3300 XL Precision Micrometer Platform)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix Extension (-02):\u003c\/strong\u003e Designates scale units configuration option 02 (Metric units calibration scaling from 0 to 25 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e \u003cstrong\u003e3300 XL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ch4\u003e1. Metrology \u0026amp; Measurement Performance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e 0 to 25 mm (Metric scale units)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.0005 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Accuracy:\u003c\/strong\u003e + 0.0004 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Mechanical Construction \u0026amp; Materials\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Button:\u003c\/strong\u003e AISI 4140 Alloy Steel, 30.5 mm (1.20 in) diameter flat target surface\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing Material (Precision Micrometer):\u003c\/strong\u003e Ruggedized fiberglass and high-impact plastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing Material (Shaft Micrometer variant):\u003c\/strong\u003e ABS Plastic structural housing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Dimensions:\u003c\/strong\u003e Height 226 mm (8.9 in); Width 274 mm (10.8 in); Length 356 mm (14.0 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 6.8 kg (14.5 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCalibration \u0026amp; Testing Workflow Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Mounting:\u003c\/strong\u003e Secure the proximity probe firmly into the built-in probe mounting adapter to ensure zero mechanical play or axial misalignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Simulation:\u003c\/strong\u003e Rotate the micrometer dial to advance or retract the AISI 4140 target button toward the probe tip in precise metric increments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Acquisition:\u003c\/strong\u003e Intercept the Proximitor sensor output signal using a high-impedance digital voltmeter to record DC gap voltages at each step.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurve Verification:\u003c\/strong\u003e Compare the newly generated displacement versus voltage curve against published Bently Nevada factory specifications or API 670 guidelines to validate linearity and scale factor compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic Capabilities \u0026amp; Verification Checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Range Assessment:\u003c\/strong\u003e Verifies whether the Proximitor sensor maintains its linear operating range without premature voltage clipping or flattening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor Alarm Check:\u003c\/strong\u003e Validates proper trip point actuation and voltage scaling of connected machinery protection monitors (such as 3500 rack monitors) by injecting known gap displacements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Expert Guidance\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight highlights that physical wear or micro-burrs on the AISI 4140 target button surface can introduce sub-micron calibration errors during low-range testing. Technicians should inspect the target face before every calibration cycle and ensure the micrometer is stored in a temperature-controlled environment to prevent thermal expansion discrepancies in the metric lead screw.\u003c\/p\u003e\n\u003ch3\u003eCompatible Equipment \u0026amp; Target Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Hardware:\u003c\/strong\u003e Bently Nevada 3300 XL 8mm and 5mm proximity transducer systems, Proximitor sensors, and 3500 monitoring system channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Scenarios:\u003c\/strong\u003e In-house instrument metrology laboratories, pre-installation acceptance testing for critical turbomachinery turnarounds, and periodic diagnostic audits of vibration monitoring loops in oil refineries and power generation plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics, Fulfillment \u0026amp; Warranty Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Carriers:\u003c\/strong\u003e Express global dispatch via \u003cstrong\u003eFedEx\u003c\/strong\u003e, \u003cstrong\u003eUPS\u003c\/strong\u003e, and \u003cstrong\u003eDHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFulfillment Speed:\u003c\/strong\u003e Guaranteed processing and dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Fully backed by a 12-month factory replacement or repair warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 330185-02 verify API 670 compliance for a proximity system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBy stepping the target button across precise known metric increments from 0 to 25 mm, it maps the exact voltage output to check if the Incremental Scale Factor (ISF) and Deviation from Straight Line (DSL) fall within API 670 tolerances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required for the micrometer lead screw mechanism?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKeep the metric lead screw clean and free of airborne metallic dust or grit, and periodically apply a light film of instrument-grade instrument oil to maintain smooth 0.0005 mm resolution feedback.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this micrometer be used for non-standard target materials like stainless steel or aluminum?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard target button is optimized for AISI 4140 alloy steel; testing probes against different target metallurgy requires applying correction factors because eddy current response varies with material electrical conductivity and magnetic permeability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the best selection guidelines when ordering this calibration tool?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure your facility operates under metric engineering standards; if your plant uses imperial measurement units, verify whether the metric -02 suffix model or an imperial variation aligns with your local quality assurance documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is my voltmeter reading fluctuating during a static calibration test?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVoltage fluctuations usually stem from poor electrical grounding of the Proximitor power supply, electromagnetic interference from nearby variable frequency drives, or loose terminal connections on the voltmeter test leads.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013951512758,"sku":"330185-02","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330185-01.jpg?v=1787034116","url":"https:\/\/www.plcsparehub.com\/products\/330185-02-3300-xl-precision-micrometer-bently-nevada-calibrator","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}