{"product_id":"330180-x0-05-143945-05-bently-nevada-3300-xl-proximity-sensor-module","title":"330180-X0-05 143945-05 Bently Nevada 3300 XL Proximity Sensor Module","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003eBently Nevada 330180-X0-05\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e for non-contact machinery monitoring systems. It conditions proximity probe signals and provides a corresponding voltage output. The sensor supports shaft displacement and vibration measurement applications. Its compact housing supports high-density DIN-rail installations. It also supports traditional panel mounting through a four-hole footprint. The insulated mounting base eliminates separate isolator plates. This design simplifies mechanical installation and electrical isolation. The sensor provides improved immunity to radio frequency and electromagnetic interference. It supports installation in fiberglass housings without special metallic enclosures. SpringLoc terminal blocks simplify field wiring. They eliminate screw-clamping mechanisms and reduce connection-related maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330180-X0-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMOD Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e143945-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX0 – Requires MOD-specific verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 – CSA, ATEX and IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 Series 5 mm and 3300 XL 8 mm proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExtension Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible 3300-series extension cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply with Barriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-23 to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV\/V change in output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +100°C (-62°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +105°C (-62°F to +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA308 Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246 g (8.67 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eMeasurement and Signal Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Function:\u003c\/strong\u003e Non-contact displacement and vibration signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Input:\u003c\/strong\u003e Accepts compatible 3300-series proximity probe and extension cable combinations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e Provides a voltage signal for machinery monitoring equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e Depends on the connected probe system and monitoring configuration. Verify the complete system specifications before application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range:\u003c\/strong\u003e Depends on the selected probe and extension cable combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e Determined by the complete measurement chain and receiving instrument.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Stability:\u003c\/strong\u003e Supply sensitivity remains below 2 mV per volt change.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e 50 Ω.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: The supplied specifications do not establish numerical frequency response, linearity, resolution, or measurement range. Confirm these values against the applicable probe system documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eKey Features and Engineering Advantages\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Installation:\u003c\/strong\u003e Supports high-density DIN-rail mounting in control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Supports traditional four-hole panel mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e The mounting base provides isolation without additional plates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRFI\/EMI Immunity:\u003c\/strong\u003e Improved interference resistance supports demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiberglass Housing Compatibility:\u003c\/strong\u003e Reduces dependence on special metallic enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpringLoc Terminals:\u003c\/strong\u003e Simplify field wiring without special installation tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced Maintenance:\u003c\/strong\u003e Screw-free terminal connections eliminate screw-clamping adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Approvals:\u003c\/strong\u003e Supports CSA, ATEX and IECEx approved installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the complete model number and MOD configuration before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected probe and extension cable combination.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor on a compatible DIN rail or panel mounting surface.\u003c\/li\u003e\n\u003cli\u003eUse the four-hole footprint for traditional panel installations.\u003c\/li\u003e\n\u003cli\u003eConnect the probe and extension cable according to the wiring diagram.\u003c\/li\u003e\n\u003cli\u003eVerify the negative DC supply voltage and polarity.\u003c\/li\u003e\n\u003cli\u003eUse approved barriers when the installation requires them.\u003c\/li\u003e\n\u003cli\u003eFollow Bently Nevada installation drawing 140979 for applicable nonincendive circuits.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-voltage and switching circuits.\u003c\/li\u003e\n\u003cli\u003eVerify terminal connections before energizing the monitoring system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Note:\u003c\/strong\u003e Operation above -23.5 VDC can reduce the available linear range. Maintain the specified supply voltage for the selected installation configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCommissioning, Diagnostics and Maintenance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Inspection:\u003c\/strong\u003e Check the sensor housing, mounting base and terminal condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Verification:\u003c\/strong\u003e Measure the DC supply at the sensor terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Verification:\u003c\/strong\u003e Check output voltage against the expected probe gap and operating condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Inspection:\u003c\/strong\u003e Inspect probe cables and connectors for mechanical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterference Diagnosis:\u003c\/strong\u003e Check grounding, cable routing and nearby switching equipment if signals fluctuate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Maintenance:\u003c\/strong\u003e Inspect SpringLoc terminals during scheduled cabinet maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Monitoring:\u003c\/strong\u003e Keep operating temperatures within the specified limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eCompatibility and System Integration\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #008000;\"\u003e330180-X0-05\u003c\/span\u003e\u003c\/strong\u003e works with compatible Bently Nevada 3300-series proximity measurement components.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Systems:\u003c\/strong\u003e 3300 Series 5 mm and 3300 XL 8 mm proximity probes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtension Cables:\u003c\/strong\u003e Compatible 3300-series extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring Equipment:\u003c\/strong\u003e Compatible machinery protection and monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Systems:\u003c\/strong\u003e Compatible DIN-rail and traditional four-hole panel arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-Area Installations:\u003c\/strong\u003e Follow the applicable approval conditions and installation drawings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify the probe, extension cable, sensor and barrier combination as one complete measurement chain. Do not assume compatibility based on connector appearance alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCertifications and Environmental Compliance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Approved configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Approved configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE-Related EMC Performance:\u003c\/strong\u003e Improved RFI\/EMI immunity supports European EMC requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -52°C to +100°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -52°C to +105°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the exact approval markings and certificate conditions on the product nameplate. Installation must follow the applicable hazardous-area requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePackaging and Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Bently Nevada 330180-X0-05 Proximitor Sensor.\u003c\/li\u003e\n\u003cli\u003eModel and MOD configuration identification.\u003c\/li\u003e\n\u003cli\u003eProtective packaging for transportation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original in Factory Packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Factory Warranty: 12 Months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS and DHL available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e 24–48 hours shipping, subject to stock confirmation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary function of the Bently Nevada 330180-X0-05?\u003c\/strong\u003e The sensor conditions signals from compatible proximity probes. It provides voltage outputs for shaft displacement and vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 330180-X0-05 replace an older Bently Nevada Proximitor Sensor?\u003c\/strong\u003e Replacement depends on the probe system, mounting footprint, wiring and electrical specifications. Engineers should compare the complete part number and MOD configuration before substitution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers check when the output signal becomes unstable?\u003c\/strong\u003e First, measure the DC supply voltage at the sensor terminals. Then inspect grounding, cable routing, connector condition and probe clearance. Check nearby electromagnetic interference sources before replacing the sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should buyers verify the X0 configuration before ordering?\u003c\/strong\u003e Check the complete MOD number, including 143945-05. Confirm the required mounting arrangement and total-length configuration with the manufacturer documentation. Do not determine these details from X0 alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should buyers provide when requesting a replacement?\u003c\/strong\u003e Provide the complete model number, MOD number and product nameplate information. Also include the connected probe model and extension cable length. These details help verify electrical and mechanical compatibility before purchase.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68155146764470,"sku":"330180-X0-05","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330180-12-05_985514a0-a6a6-4bfc-9ee1-c240380c837a.jpg?v=1795576113","url":"https:\/\/www.plcsparehub.com\/products\/330180-x0-05-143945-05-bently-nevada-3300-xl-proximity-sensor-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}