{"product_id":"330165-50-00-01-00-bently-nevada-3300-xl-rotary-position-transducer","title":"330165-50-00-01-00 Bently Nevada 3300 XL Rotary Position Transducer","description":"\u003ch3\u003e\u003cstrong\u003eProduct Executive Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330165-50-00-01-00\u003c\/strong\u003e\u003c\/span\u003e is a precision non-contacting eddy-current rotary position transducer within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 3300 XL Series\u003c\/strong\u003e\u003c\/span\u003e. Designed primarily for monitoring critical steam turbine valve positions, this sensor converts angular rotation into proportional gap voltage signals to give plant operators real-time feedback on governor and throttle valve positioning.\u003c\/p\u003e\n\u003cp\u003eConfigured with a 5-meter integrated system, panel-mount Proximitor sensor chassis, and a 100-degree maximum rotational range, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330165-50-00-01-00\u003c\/strong\u003e\u003c\/span\u003e houses a precision-machined 4140 steel internal cylinder and non-contacting 3300 XL probe within a rugged cast aluminum enclosure. Operating on a -17.5 Vdc to -26 Vdc power rail, it directly interfaces with \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3500\/45 Position Monitors\u003c\/strong\u003e\u003c\/span\u003e for continuous machinery protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insight \u0026amp; Field Engineering Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn thermal power plants and combined-cycle generation facilities, accurate valve feedback from the \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330165-50-00-01-00\u003c\/strong\u003e\u003c\/span\u003e is vital for load dispatching and thermodynamic efficiency. Our rotating machinery specialists frequently specify this unit during turbine control system retrofits to replace wear-prone mechanical potentiometers with non-contact eddy-current technology.\u003c\/p\u003e\n\u003cp\u003eDuring an emergency turnaround on a 250MW steam turbine, erratic valve position feedback caused hunting on the main governor valve. Field inspection revealed mechanical slop in a legacy contact sensor. Replacing the unit with a calibrated \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330165-50-00-01-00\u003c\/strong\u003e\u003c\/span\u003e RPT stabilized the loop and restored smooth automatic load control across the entire 100-degree stroke sweep.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul style=\"list-style-type: none; padding-left: 10px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e330165\u003c\/strong\u003e — Model Designation: \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Rotary Position Transducer (RPT)\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003e50\u003c\/strong\u003e — System Length: 5-Meter System with Integrated 5-Meter Probe (No Extension Cable)\u003c\/li\u003e\n\u003cli\u003e      └── \u003cstrong\u003e00\u003c\/strong\u003e — Mounting Option: Panel Mount Proximitor Sensor Chassis\u003c\/li\u003e\n\u003cli\u003e          └── \u003cstrong\u003e01\u003c\/strong\u003e — Rotational Range: 100 Degrees Maximum Angular Sweep\u003c\/li\u003e\n\u003cli\u003e              └── \u003cstrong\u003e00\u003c\/strong\u003e — Approvals Option: Standard Unapproved \/ Non-Hazardous Location\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameters \u0026amp; Materials Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \/ Manufacturer:\u003c\/strong\u003e Bently Nevada \/ Baker Hughes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330165-50-00-01-00\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL Machinery Protection System\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage Requirements:\u003c\/strong\u003e -17.5 Vdc to -26 Vdc @ 12 mA Maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Sensitivity:\u003c\/strong\u003e Less than 2 mV change in output per Volt input change\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance:\u003c\/strong\u003e 50 Ω nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe DC Resistance (Rprobe):\u003c\/strong\u003e 8.73 ± 0.70 Ω (Center to Outer Conductor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotational Operating Range:\u003c\/strong\u003e 0 to 100 Degrees\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Temperature Rating:\u003c\/strong\u003e -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Tip Material:\u003c\/strong\u003e Polyphenylene Sulfide (PPS)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Body \/ Shaft Material:\u003c\/strong\u003e AISI 304 Stainless Steel \/ 303 Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure \u0026amp; Housing:\u003c\/strong\u003e Cast Aluminum with 2024 Aluminum Conduit Fitting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Ramp Material:\u003c\/strong\u003e 4140 Alloy Steel Cylinder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBearings:\u003c\/strong\u003e Sintered Bronze MIL-B-5687A (Vacuum-Impregnated MIL-L-6085)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e 75 Ω Triaxial FEP Insulated Cable with Gold-Plated Brass Connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Tensile Load:\u003c\/strong\u003e 330 N (75 lbf) Case-to-Cable \/ 270 N (60 lbf) Lead Connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios \u0026amp; Machinery Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous angular position feedback on main steam turbine inlet valves, reheat stop valves, and bypass control valves.\u003c\/li\u003e\n\u003cli\u003eStroke measurement on heavy hydraulic actuators, process dampers, and industrial governor linkage shafts.\u003c\/li\u003e\n\u003cli\u003eIntegration with Bently Nevada 3500\/45 position monitoring modules for real-time valve position telemetry and trip logic.\u003c\/li\u003e\n\u003cli\u003eDiagnostics leveraging built-in \"Transducer OK\" circuit detection to continuously verify DC gap voltage integrity and cable continuity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation, Maintenance \u0026amp; Logistics Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eMount the main RPT housing securely to the turbine frame and align the 303 stainless steel shaft with the steam valve control shaft using a flexible coupling to prevent radial bearing loading. Ensure cable routing respects the minimum 25.4 mm (1.0 in) bend radius to protect internal triaxial shielding from degradation.\u003c\/p\u003e\n\u003cp\u003eWhen wiring the panel-mount Proximitor, ensure clean -24Vdc supply power and verify shield grounding at the monitor end only to prevent ground loop noise from corrupting output sensitivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 330165-50-00-01-00 RPT Assembly\u003c\/strong\u003e\u003c\/span\u003e, including panel-mount Proximitor sensor unit and installation summary sheet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Express Delivery:\u003c\/strong\u003e Dispatched globally within 24 to 48 hours utilizing priority express couriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty Guarantee:\u003c\/strong\u003e Backed by a full 12-month replacement warranty covering mechanical, electrical, and sensor calibration defects under standard plant operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions \u0026amp; Technical Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What determines whether a plant should select the 100-degree (01) versus a 200 or 300-degree rotational range variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Selection depends entirely on the physical shaft rotation of the steam valve mechanism. Choosing the 100-degree option for linkage systems with less than 100 degrees of total travel maximizes the voltage-per-degree resolution and accuracy fed into the monitoring system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How do technicians verify proper mechanical alignment during field installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Set the valve to its fully closed baseline position, verify mechanical zero on the internal cylinder, and measure the Proximitor output DC voltage. Adjust the flexible coupling until the gap voltage matches the baseline zero specification listed on the system calibration card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What causes a \"Not OK\" status fault on the associated 3500\/45 monitor channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: A channel \"Not OK\" alarm usually points to a broken triaxial cable lead, an open circuit in the probe coil (Rprobe outside 8.03–9.43 Ω), or supply voltage dropping below the required -17.5 Vdc threshold.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Why is an flexible coupling mandatory when connecting the sensor shaft to the turbine valve stem?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA4: Thermal expansion and mechanical vibration from the turbine frame create slight axial and radial runout. A flexible coupling absorbs these movements, preventing premature failure of the internal vacuum-impregnated sintered bronze bearings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Can the 5-meter integrated probe cable on this assembly be shortened or lengthened in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA5: No, eddy-current transducer systems are factory-calibrated to the exact electrical length of their cable system (5.0 meters). Cutting or splicing the triaxial cable alters system inductance and capacitance, destroying measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330165.png?v=1784791673\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45277415014582,"sku":"330165-50-00-01-00","price":285.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330165_2.jpg?v=1784791984","url":"https:\/\/www.plcsparehub.com\/products\/330165-50-00-01-00-bently-nevada-3300-xl-rotary-position-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}