{"product_id":"330140-08-20-11-00-bently-nevada-3300-xl-8mm-proximity-probe","title":"330140-08-20-11-00 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e3300 XL 8 mm\u003c\/span\u003e proximity probe from \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003eBently Nevada\u003c\/span\u003e delivers high-precision relative shaft vibration and position measurements. Engineered with patented TipLoc and CableLoc technologies, this sensor provides superior mechanical pull strength and rugged environmental durability for critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003ePart Characteristic\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left;\"\u003eConfiguration \/ Technical Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eBrand \u0026amp; Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eBently Nevada | \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e (\u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e3300 XL Series\u003c\/span\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eCase Length \u0026amp; Total Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e08 Option (0.8 in case) | 20 Option (2.0 meters \/ 6.6 feet total length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eConnector \u0026amp; Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e11 Option (Miniature ClickLoc coaxial connector, connector protector, FluidLoc cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e00 Option (Unclassified \/ Standard non-hazardous location)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e7.87 V\/mm (200 mV\/mil) ±5% over 80 mil linear range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eLinearity (DSL Deviation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eLess than ±0.025 mm (±1 mil) deviation from best fit straight line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eElectrical Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003eProbe DC resistance RPROBE = 7.88 ± 0.50 ohms across 2.0m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px;\"\u003e\u003cstrong\u003eThermal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 8px;\"\u003e-52°C to +177°C (-62°F to +350°F) standard operating envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility and System Architecture\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e interfaces directly with standard \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e3300 XL Proximitor Sensors\u003c\/span\u003e and extension cables to establish a calibrated 5-meter or 9-meter measurement loop. The built-in FluidLoc cable structure halts capillary oil migration through internal conductor bundles, protecting control cabinet electronics from fluid contamination.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the 8 mm probe body into the machinery mounting hole using finger-tight adjustment.\u003c\/li\u003e\n\u003cli\u003eApply correct torque specifications to prevent crushing the PPS plastic probe tip encapsulation.\u003c\/li\u003e\n\u003cli\u003eSecure the miniature coaxial ClickLoc connector to the extension cable and install the included connector protector.\u003c\/li\u003e\n\u003cli\u003eVerify that ambient installation temperatures remain above -34°C to protect the Viton O-ring pressure seal from thermal shock.\u003c\/li\u003e\n\u003cli\u003eRoute the non-armored cable safely away from sharp metallic edges and high-friction vibration zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003eThe thicker PPS tip encapsulation yields enhanced resistance against physical abuse during tight mechanical alignments. The inclusion of factory connector protectors safeguards gold-plated contacts from moisture corrosion in humid compressor sheds. Technicians can rapidly verify loop integrity by confirming zero baseline voltage drift.\u003c\/p\u003e\n\u003ch3\u003eApplication Scenarios and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam \u0026amp; Gas Turbines:\u003c\/strong\u003e Measures radial journal vibration and thrust position on large turbine generators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e Tracks shaft centerline movement and dynamic orbit patterns under load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Tracking:\u003c\/strong\u003e Identifies sub-synchronous whirl, oil whip, and shaft imbalance conditions via precise voltage output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertification, Packing List, and Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals:\u003c\/strong\u003e Standard non-hazardous configuration (Option 00).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePacking List:\u003c\/strong\u003e One \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e probe packed securely in original factory casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Terms:\u003c\/strong\u003e Covered by a comprehensive 12-month manufacturer replacement warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogistics:\u003c\/strong\u003e Fast dispatch within 24-48 hours via premium couriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eOur engineering team at Global PLC Spare HUB frequently observes that over-torqueing 8 mm probe cases causes internal coil distortion and linearity loss. When installing the \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e, always utilize calibrated wrench limits and ensure the thread engagement matches proper depth guidelines to maintain accurate 200 mV\/mil scaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific engineering advantage does the FluidLoc cable option provide on the \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e330140-08-20-11-00\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The FluidLoc design blocks oil and liquid from wicking through the internal cable strands, preventing fluid leakage into terminal housings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is sub-zero installation cautioned against when handling the probe pressure seal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Exposing the probe to temperatures below -34°C during installation can stiffen the Viton O-ring and cause premature pressure seal failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the TipLoc molding method improve long-term sensor reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: TipLoc creates a solid chemical and mechanical bond between the PPS probe tip and the stainless steel body, preventing tip separation under high-vibration stress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this 2.0-meter probe system be combined interchangeably with older 3200-series monitoring racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, \u003cspan style=\"color: #0b5ed7; font-weight: bold;\"\u003e3300 XL\u003c\/span\u003e systems require matching 3300 XL Proximitor sensors to maintain correct incremental scale factors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What selection factors should I consider when choosing between armored and non-armored probe variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Choose non-armored variants like this model when cable trays offer sufficient physical routing protection and tight space constraints prevent bending stiff armor conduits.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_330141_330197_330198.png?v=1784785679\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013950824630,"sku":"330140-08-20-11-00","price":275.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_86e30592-ff85-42e6-b5d2-5623276444f9.jpg?v=1789452716","url":"https:\/\/www.plcsparehub.com\/products\/330140-08-20-11-00-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}