{"product_id":"330140-08-20-01-05-bently-nevada-proximity-probe-3300-xl-sensor","title":"330140-08-20-01-05 Bently Nevada Proximity Probe | 3300 XL Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Rugged 8 mm Eddy-Current Sensing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #c0392b;\"\u003eBently Nevada 330140-08-20-01-05\u003c\/span\u003e\u003c\/strong\u003e belongs to the \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e family. It measures shaft displacement without physical contact when connected to a compatible driver and monitoring system.\u003c\/p\u003e\n\u003cp\u003eThis configuration specifies a 0.8-inch overall case length, a 2.0-meter probe length, and a miniature coaxial ClickLoc connector with a connector protector. Its agency approval code specifies CSA, ATEX, and IECEx approvals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003e330140-08-20-01-05\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 3300 XL 8 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Unarmored eddy-current proximity probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A., according to the supplied product information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e New and original in factory packing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to confirmed supplier terms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and service availability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Typically within 24–48 hours after order confirmation and stock verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Ordering Code Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the complete suffix sequence to verify the probe's physical dimensions, cable arrangement, and approval requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eEngineering Significance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330140\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe\u003c\/td\u003e\n\u003ctd\u003eUnarmored probe construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e08\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e0.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal probe length\u003c\/td\u003e\n\u003ctd\u003e2.0 m (6.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnector and cable option\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector and standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, and IECEx approvals, as specified for this configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering control:\u003c\/strong\u003e Confirm all five code sections against the installed probe and applicable manufacturer documentation. Connector construction and hazardous-area approvals can determine whether a replacement suits the existing installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Mechanical and Electrical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330140-08-20-01-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e0.8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Probe Length\u003c\/td\u003e\n\u003ctd\u003e2.0 m (6.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard cable, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Probe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.88 ± 0.50 ohms for the 2.0 m probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Weight Reference\u003c\/td\u003e\n\u003ctd\u003e323 g\/m, according to the supplied specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity Performance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in average scale factor under the specified humidity test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months, subject to supplier terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWeight note:\u003c\/strong\u003e The supplied 323 g\/m figure is a mass-per-length value. Confirm the exact assembly weight from the applicable manufacturer datasheet before using it for shipping calculations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Measurement Accuracy and Calibration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe probe forms part of a calibrated eddy-current measurement system. Its performance depends on the matched probe, extension cable, driver, target material, and operating conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Parameter\u003c\/th\u003e\n\u003cth\u003ePublished Specification\u003c\/th\u003e\n\u003cth\u003eTest Conditions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) ±5%\u003c\/td\u003e\n\u003ctd\u003eStandard 1 m and 5 m systems, measured over an 80 mil linear range from 0°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) ±6.5%\u003c\/td\u003e\n\u003ctd\u003eStandard 9 m systems and specified extended-temperature configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best-Fit Straight Line\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.025 mm (±1 mil)\u003c\/td\u003e\n\u003ctd\u003eStandard 1 m and 5 m systems at 0°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviation from Best-Fit Straight Line\u003c\/td\u003e\n\u003ctd\u003eLess than ±0.038 mm (±1.5 mil)\u003c\/td\u003e\n\u003ctd\u003eStandard 9 m and specified extended-temperature systems at 0°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range Reference\u003c\/td\u003e\n\u003ctd\u003e80 mil linear range\u003c\/td\u003e\n\u003ctd\u003ePublished performance conditions for the applicable calibrated system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant configuration note:\u003c\/strong\u003e The supplied accuracy figures distinguish 1 m, 5 m, and 9 m measurement systems. This product has a 2.0 m probe length. Do not automatically apply the 1 m or 5 m system accuracy figures to this assembly. Confirm the complete probe, extension cable, and driver configuration before specifying accuracy.\u003c\/p\u003e\n\u003cp\u003eThe figures above describe scale factor and linearity under stated conditions. They do not independently establish frequency response, system resolution, or performance at every operating temperature.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Temperature, Sealing, and Environmental Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard probe operating and storage temperature:\u003c\/strong\u003e -52°C to +177°C (-62°F to +350°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended-temperature probe tip:\u003c\/strong\u003e -52°C to +218°C (-62°F to +425°F), for the applicable extended-temperature configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended-temperature cable and connector:\u003c\/strong\u003e -51°C to +260°C (-60°F to +500°F), for the applicable configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure sealing:\u003c\/strong\u003e The probe seals differential pressure between the probe tip and case.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal material:\u003c\/strong\u003e Viton O-ring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure testing:\u003c\/strong\u003e The manufacturer states that probes are not pressure-tested before shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-temperature caution:\u003c\/strong\u003e Exposure below -34°C (-30°F) may cause premature pressure-seal failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity performance:\u003c\/strong\u003e Less than 3% change in average scale factor after the specified 93% relative humidity test for up to 56 days, under IEC 60068-2-3 test conditions as described in the supplied information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe standard and extended-temperature figures apply to different configurations. Do not assume this specific standard probe supports the extended-temperature limits. Verify the ordered product code before use.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Design Features That Matter in the Field\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipLoc molding:\u003c\/strong\u003e Provides a stronger bond between the probe tip and body.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCableLoc construction:\u003c\/strong\u003e Provides a stated cable pull strength of 330 N (75 lbf).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 mm probe construction:\u003c\/strong\u003e Uses thicker encapsulation of the sensing coil in the molded PPS tip.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust case:\u003c\/strong\u003e The larger probe body offers greater mechanical robustness than smaller probe designs in suitable applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector protector:\u003c\/strong\u003e Helps protect the connector area during handling and installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard cable:\u003c\/strong\u003e This suffix specifies a standard cable, not the optional FluidLoc version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe optional FluidLoc cable can help prevent oil and other liquids from migrating through the cable interior. Do not assume this feature is present in the \u003cstrong\u003e330140-08-20-01-05\u003c\/strong\u003e configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Installation and Commissioning Procedure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the configuration:\u003c\/strong\u003e Verify the full part number, case length, probe length, connector option, and approval suffix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the mounting point:\u003c\/strong\u003e Check the probe port, thread condition, target clearance, and mounting depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the probe tip:\u003c\/strong\u003e Avoid impacts, contamination, and contact with the shaft target during handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the cable:\u003c\/strong\u003e Follow the manufacturer's bend-radius requirements and avoid sharp edges or crushing loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the ClickLoc interface:\u003c\/strong\u003e Verify connector compatibility and protect the connector from contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the probe gap:\u003c\/strong\u003e Follow the compatible driver instructions and the machine manufacturer's commissioning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck calibration:\u003c\/strong\u003e Confirm the installed probe, extension cable, and driver form the specified measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate channel readings:\u003c\/strong\u003e Review gap voltage, channel status, and signal stability before returning the equipment to service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify hazardous-area installation:\u003c\/strong\u003e Confirm that the applicable approval covers the complete installation and its wiring arrangement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow site isolation procedures before working near rotating machinery. Do not adjust an energized installation unless the approved procedure explicitly permits it.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Diagnostic Use and Field Examples\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis probe provides a displacement-related signal. A compatible monitoring system interprets that signal to support machinery condition assessment. The probe does not independently diagnose the root cause of a mechanical fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCase A: Gap voltage changes after replacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck mounting depth, probe gap, target clearance, and driver compatibility. Confirm that the installed cable and driver match the specified system configuration before adjusting the probe position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCase B: Vibration readings become unstable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect the connector, cable condition, mounting stability, and electrical routing. Compare gap voltage and vibration trends with baseline data. Investigate mechanical changes before condemning the probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCase C: Calibration differs from the expected value\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the correct cable system and driver calibration. The scale factor depends on the complete measurement chain. Do not use a specification for a different system length as the acceptance criterion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCase D: A probe passes a basic electrical check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA resistance reading within range does not prove correct measurement performance. Validate the signal using the manufacturer's test procedure and an appropriate monitoring or calibration setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e08 | Suitable Equipment and Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam turbines:\u003c\/strong\u003e Shaft displacement and vibration monitoring with compatible systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas turbines:\u003c\/strong\u003e Non-contact shaft monitoring in approved configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial compressors:\u003c\/strong\u003e Monitoring shaft movement and vibration-related trends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerators:\u003c\/strong\u003e Displacement monitoring at suitable measurement points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and rotating equipment:\u003c\/strong\u003e Condition monitoring where the probe geometry and driver are compatible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil and gas facilities:\u003c\/strong\u003e Machinery protection systems with appropriate hazardous-area installation approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower generation and petrochemical plants:\u003c\/strong\u003e Machinery monitoring and maintenance diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConfirm the target material, mounting geometry, cable system, operating temperature, and certification requirements for each application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e09 | Certification and Compliance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code \u003cstrong\u003e05\u003c\/strong\u003e specifies CSA, ATEX, and IECEx approvals in the supplied product information.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Confirm the applicable certificate and hazardous-area classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Verify the equipment marking and installation conditions for the intended zone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Confirm the certificate and permitted installation parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCertification applies only within the limits of the relevant approved configuration. Verify the nameplate, certificate, wiring requirements, and local regulations before installation. Do not infer a specific gas group, temperature class, or protection level without the product's certification documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e10 | Replacement Comparison and Selection Advice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Factor\u003c\/th\u003e\n\u003cth\u003e330140-08-20-01-05\u003c\/th\u003e\n\u003cth\u003e330140-08-20-11-00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e0.8 in\u003c\/td\u003e\n\u003ctd\u003e0.8 in, based on the shared code segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Probe Length\u003c\/td\u003e\n\u003ctd\u003e2.0 m\u003c\/td\u003e\n\u003ctd\u003e2.0 m, based on the shared code segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and Cable Option\u003c\/td\u003e\n\u003ctd\u003e01: ClickLoc connector with protector and standard cable\u003c\/td\u003e\n\u003ctd\u003e11: Verify the exact connector and cable definition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e05: CSA, ATEX, IECEx approvals\u003c\/td\u003e\n\u003ctd\u003e00: Approval not required under this option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Selection Concern\u003c\/td\u003e\n\u003ctd\u003eApproved configuration for the specified installation\u003c\/td\u003e\n\u003ctd\u003eConnector\/cable compatibility and approval requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eRelated product: \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330140-08-20-11-00-bently-nevada-3300-xl-8mm-proximity-probe\"\u003e\u003cstrong\u003eBently Nevada 330140-08-20-11-00 3300 XL 8 mm Proximity Probe\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical recommendation:\u003c\/strong\u003e The two models share the same base model and the first two dimensional suffixes. Their connector\/cable and approval options differ. Choose the -01-05 configuration when the installation requires the specified ClickLoc connector with protector, standard cable, and applicable approvals. Consider the -11-00 configuration only after verifying its connector arrangement and confirming that its approval status meets site requirements.\u003c\/p\u003e\n\u003cp\u003eDo not substitute solely because the base model and length match. Verify the installed driver, extension cable, connector interface, certification, and measurement-system calibration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e11 | Packaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct condition:\u003c\/strong\u003e New and original in factory packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months under the supplier's confirmed warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch time:\u003c\/strong\u003e Typically 24–48 hours after order confirmation and stock verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Factory packaging for the confirmed probe configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded accessories:\u003c\/strong\u003e Verify the connector protector, cable, and any accessories against the confirmed order and packing list.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep the product label and purchase documentation for warranty claims. Contact the sales team for coverage conditions, return authorization, and technical support.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e12 | Global PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFrom a machinery maintenance perspective, the approval suffix and cable configuration deserve the same attention as probe length. A physically compatible probe may still be unsuitable for a hazardous-area installation or an existing calibrated measurement chain.\u003c\/p\u003e\n\u003cp\u003eFor example, a maintenance team may replace a probe with the same 2.0 m length but a different connector option. The replacement may not match the existing cable interface. The team should verify the connector, driver compatibility, and certification before installation.\u003c\/p\u003e\n\u003cp\u003eWe recommend recording the complete part number, cable arrangement, driver model, installation temperature, and required hazardous-area approval before ordering. This approach reduces avoidable installation changes and commissioning delays.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e13 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why does the measurement system length matter when selecting this probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe works as part of a calibrated circuit. The probe, extension cable, and driver must form a supported combination. Verify the complete system configuration before applying scale factor or linearity limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the 330 N cable pull-strength figure mean the cable can withstand any installation load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It describes the stated CableLoc design performance. Avoid using the cable as a lifting point or applying uncontrolled pulling force during installation. Follow the manufacturer's handling instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How should engineers investigate a slow change in shaft displacement readings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the trend with operating conditions, gap voltage, machine temperature, and recent maintenance records. Check mounting stability and the measurement chain before deciding whether the change reflects actual shaft movement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should a buyer verify when a hazardous-area replacement uses a different approval suffix?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the product marking, certificate, zone or division requirements, temperature class, and installation conditions. Do not assume an unapproved option is acceptable because its mechanical dimensions match.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: When should a plant choose the optional FluidLoc cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsider it when the application requires protection against oil or liquid migration through the cable interior. Confirm the correct ordering code and installation requirements with the manufacturer. The standard cable option listed here does not establish that FluidLoc is included.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_330197_330141_330198.png?v=1784606646\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013950759094,"sku":"330140-08-20-01-05","price":246.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330140_3_399dad81-dcad-45bf-9418-47144a66d4fe.jpg?v=1792465719","url":"https:\/\/www.plcsparehub.com\/products\/330140-08-20-01-05-bently-nevada-proximity-probe-3300-xl-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}