{"product_id":"330130-085-13-05-bently-nevada-3300-xl-armored-extension-cable","title":"330130-085-13-05 Bently Nevada 3300 XL Armored Extension Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Secure Signal Transmission for 3300 XL Probe Systems\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003eBently Nevada 330130-085-13-05\u003c\/span\u003e\u003c\/strong\u003e is an armored extension cable for the \u003cstrong\u003e3300 XL 8 mm proximity probe system\u003c\/strong\u003e. It connects a compatible probe to its extension cable interface and supports accurate shaft displacement measurements when used with the correct Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eThis configuration provides an \u003cstrong\u003e8.5-meter (27.9-foot) cable length\u003c\/strong\u003e, an armored FluidLoc cable, a connector protector, and the specified CSA, ATEX, and IECEx approval option. The FluidLoc construction helps prevent oil and other liquids from migrating through the cable interior.\u003c\/p\u003e\n\u003cp\u003eFor machinery engineers, cable selection affects system length, signal performance, installation reliability, and environmental protection. Always verify the complete probe, extension cable, and Proximitor sensor combination before commissioning.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e330130-085-13-05\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e 3300 XL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Armored proximity probe extension cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Cable Length:\u003c\/strong\u003e 8.5 m (27.9 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Construction:\u003c\/strong\u003e Armored FluidLoc cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Connector protector included in the specified option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApproval Option:\u003c\/strong\u003e CSA, ATEX, and IECEx, as specified by suffix -05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Origin:\u003c\/strong\u003e USA, according to the supplied product information\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to supplier terms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown | Decode the Ordering Number\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number Segment\u003c\/th\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable\u003c\/td\u003e\n\u003ctd\u003eIdentifies the extension cable product family.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-085\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 m\u003c\/td\u003e\n\u003ctd\u003eSpecifies a nominal cable length of 8.5 meters (27.9 feet).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-13\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable with connector protector\u003c\/td\u003e\n\u003ctd\u003eCombines armored cable construction with FluidLoc liquid-migration protection and connector protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx approval option\u003c\/td\u003e\n\u003ctd\u003eIdentifies the specified approval configuration. Verify the actual certification markings and installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration advice:\u003c\/strong\u003e Do not substitute a cable based on length alone. Confirm the probe family, connector arrangement, FluidLoc requirement, armor, hazardous-area approvals, and total system length.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications | Cable and Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e330130-085-13-05\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Extension Cable Length\u003c\/td\u003e\n\u003ctd\u003e8.5 m (27.9 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCenter Conductor Resistance\u003c\/td\u003e\n\u003ctd\u003e1.87 ± 0.28 Ω for an 8.5 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Conductor Resistance\u003c\/td\u003e\n\u003ctd\u003e0.56 ± 0.11 Ω for an 8.5 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Output Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ω for the referenced 3300 XL system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 to -26 VDC for the specified nonincendive installation; -23 to -26 VDC with barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA for the referenced system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Linear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) for the referenced 3300 XL 8 mm system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring\u003c\/td\u003e\n\u003ctd\u003e0.2–1.5 mm² (16–24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wiring Length\u003c\/td\u003e\n\u003ctd\u003e305 m (1,000 ft) between the Proximitor sensor and monitor, subject to frequency-response requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Humidity Performance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in Average Scale Factor after testing at 93% relative humidity for up to 56 days under IEC 60068-2-3 conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant distinction:\u003c\/strong\u003e The power, linear range, and output resistance values describe the referenced 3300 XL 8 mm measurement system. They are not independent electrical outputs generated by the passive extension cable.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Construction and Liquid Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmored Cable:\u003c\/strong\u003e Provides additional mechanical protection for suitable industrial routing conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluidLoc Construction:\u003c\/strong\u003e Helps prevent oil and other liquids from migrating through the cable interior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protector:\u003c\/strong\u003e Protects the probe-to-extension cable connection when correctly installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilicone Tape:\u003c\/strong\u003e Supplied silicone tape may serve as an alternative to connector protectors in suitable applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil Exposure Warning:\u003c\/strong\u003e Do not rely on silicone tape where turbine oil may contact the probe-to-extension cable connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FluidLoc option is particularly relevant around turbine casings and oil-exposed machinery. It does not eliminate the need for correct connector assembly, sealing, and inspection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility | Probe, Cable, and Proximitor Matching\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe extension cable forms part of the complete 3300 XL 8 mm proximity measurement system. Engineers must match the combined probe and extension cable length to the Proximitor sensor's required total system length.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Compatibility:\u003c\/strong\u003e Use with the appropriate 3300 XL 8 mm probe configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProximitor Sensor:\u003c\/strong\u003e Verify that the sensor supports the selected probe and extension cable combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal System Length:\u003c\/strong\u003e The probe length plus extension cable length must equal the Proximitor sensor's specified total length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Material:\u003c\/strong\u003e The referenced performance specifications use an AISI 4140 steel target. Other target materials may change system performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Conditions:\u003c\/strong\u003e Referenced specifications assume a -24 VDC supply, 10 kΩ load, and a 1.27 mm (50 mil) probe gap unless otherwise indicated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Use compatible shielded triad cable and suitable tinned field wiring where specified by the installation documentation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The referenced 3300 XL 8 mm system provides a linear range of approximately 0.25–2.3 mm (10–90 mils), corresponding approximately to -1 to -17 VDC under the stated conditions. Confirm the applicable Proximitor documentation before using these values for commissioning.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide | Practical Steps for Engineers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the Part Number:\u003c\/strong\u003e Confirm the cable length, FluidLoc option, armor, connector protector, and approval suffix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck System Length:\u003c\/strong\u003e Add the probe length and extension cable length. Confirm that the total matches the selected Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect Connectors:\u003c\/strong\u003e Check for damaged threads, contamination, moisture, or worn sealing components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the Cable:\u003c\/strong\u003e Avoid sharp edges, excessive bending, crushing, and unnecessary contact with hot surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the Armor:\u003c\/strong\u003e Install the armored cable according to the approved routing and mechanical support requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the Connection:\u003c\/strong\u003e Install the connector protector correctly, particularly where oil exposure is possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify Hazardous-Area Requirements:\u003c\/strong\u003e Follow the applicable approval documentation and installation drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommission the System:\u003c\/strong\u003e Check supply voltage, gap voltage, channel response, and vibration or shaft-position readings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eNever shorten or modify a cable without confirming the manufacturer's instructions. Cable alterations may affect electrical characteristics, environmental protection, and the approved system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Maintenance | Finding Cable-Related Faults\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved Symptom\u003c\/th\u003e\n\u003cth\u003ePotential Cause\u003c\/th\u003e\n\u003cth\u003eRecommended Inspection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent shaft readings\u003c\/td\u003e\n\u003ctd\u003eLoose connector, damaged conductor, or unstable connection\u003c\/td\u003e\n\u003ctd\u003eInspect connector engagement, cable routing, and continuity using approved procedures.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected gap voltage\u003c\/td\u003e\n\u003ctd\u003eIncorrect system length, wiring fault, or incompatible component\u003c\/td\u003e\n\u003ctd\u003eVerify probe and extension cable lengths, then check the Proximitor configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal drift after oil exposure\u003c\/td\u003e\n\u003ctd\u003eConnector contamination or compromised sealing\u003c\/td\u003e\n\u003ctd\u003eInspect the connection and FluidLoc installation for signs of oil migration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcessive high-frequency noise\u003c\/td\u003e\n\u003ctd\u003eElectrical interference, poor routing, or incorrect field wiring\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing, shielding, grounding, and the monitoring channel's frequency response.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable readings after replacement\u003c\/td\u003e\n\u003ctd\u003eIncorrect cable length or mismatched system components\u003c\/td\u003e\n\u003ctd\u003eConfirm the complete probe, extension cable, and Proximitor sensor combination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A turbine monitoring channel develops intermittent shaft-position readings after cable replacement. Before changing the probe, technicians should confirm the extension cable length, inspect the connector, and verify the total system length.\u003c\/p\u003e\n\u003cp\u003eFor an oil-exposed installation, inspect the probe-to-extension cable connection for contamination or signs of leakage. Correct cable configuration and sealing help reduce avoidable maintenance work.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas | Where This Cable Adds Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam Turbines:\u003c\/strong\u003e Supports compatible shaft-position and vibration measurement systems around turbine machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Turbines:\u003c\/strong\u003e Provides a protected cable connection for suitable proximity probe installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Compressors:\u003c\/strong\u003e Supports the signal path between a compatible probe and extension cable system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Pumps:\u003c\/strong\u003e Helps maintain a reliable probe connection when the system uses a matching 3300 XL 8 mm configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Supports machinery monitoring installations requiring armored routing and suitable liquid protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil and Gas Facilities:\u003c\/strong\u003e Provides a FluidLoc cable option for suitable installations exposed to oil or other liquids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication suitability depends on system compatibility, mechanical routing, environmental exposure, and the required hazardous-area approvals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Comparison | 330130-085-13-05 vs. 330130-040-01-05\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBoth part numbers belong to the Bently Nevada 3300 XL extension cable family. The main known differences are the ordered cable length and connector protector\/cable option.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Factor\u003c\/th\u003e\n\u003cth\u003e330130-085-13-05\u003c\/th\u003e\n\u003cth\u003e330130-040-01-05\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length Code\u003c\/td\u003e\n\u003ctd\u003e-085: 8.5 m (27.9 ft)\u003c\/td\u003e\n\u003ctd\u003e-040: Confirm the corresponding length in the product documentation before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Option Code\u003c\/td\u003e\n\u003ctd\u003e-13: Armored FluidLoc cable with connector protector\u003c\/td\u003e\n\u003ctd\u003e-01: Confirm the connector protector and cable construction from the official ordering information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Option\u003c\/td\u003e\n\u003ctd\u003e-05: CSA, ATEX, IECEx\u003c\/td\u003e\n\u003ctd\u003e-05: CSA, ATEX, IECEx, subject to the actual product certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Exposure\u003c\/td\u003e\n\u003ctd\u003eFluidLoc construction helps limit internal liquid migration.\u003c\/td\u003e\n\u003ctd\u003eVerify whether the specified cable construction includes FluidLoc protection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Requirements\u003c\/td\u003e\n\u003ctd\u003eSuitable when the 8.5 m length and armored FluidLoc construction match the installation.\u003c\/td\u003e\n\u003ctd\u003eSuitable only when the verified cable length and construction meet the installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Link\u003c\/td\u003e\n\u003ctd\u003eCurrent requested model\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330130-040-01-05-bently-nevada-extension-cable-3300-xl\"\u003eView 330130-040-01-05\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical recommendation:\u003c\/strong\u003e Choose the 8.5 m FluidLoc armored version when the installation needs that length and added liquid-migration protection. Consider the alternative only after confirming its actual length, cable construction, connector protection, and system compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eExtension cable selection is a system-level engineering decision, not simply a matter of matching connector types. The probe length, extension cable length, and Proximitor sensor configuration must work together.\u003c\/p\u003e\n\u003cp\u003eFor example, when replacing a cable on a turbine casing, a technician may choose a similar-looking cable with a different length or connector option. This change can create a system mismatch or remove an important layer of liquid protection.\u003c\/p\u003e\n\u003cp\u003eOur recommendation is to record the full cable part number, probe model, Proximitor model, total system length, and environmental exposure before ordering. For oil-exposed connections, verify FluidLoc requirements and install the connector protector according to the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eThis process helps engineers avoid unnecessary commissioning delays and supports more consistent machinery monitoring performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty, Packaging, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 330130-085-13-05 extension cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to the supplier's applicable terms and conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Target:\u003c\/strong\u003e 24–48 hours after order confirmation, subject to stock verification and order processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Check:\u003c\/strong\u003e Confirm the complete suffix, cable length, and required accessories before shipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e Verify the extension cable, specified connector protector, silicone tape, and documentation against the supplier's packing list.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why must the probe length and extension cable length match the Proximitor sensor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm system relies on a defined total electrical length. An incorrect combination can affect measurement performance and system calibration. Verify the complete configuration before energizing the channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the armored FluidLoc option necessary for every installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It is especially useful where the installation requires additional mechanical protection and resistance to internal liquid migration. Select the option according to cable routing, oil exposure, and the machine manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can silicone tape replace the connector protector in a turbine installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied silicone tape may serve as an alternative in suitable applications. The manufacturer does not recommend it where turbine oil can expose the probe-to-extension cable connection. Use the specified connector protection for those conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should engineers check before extending the field wiring to the monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the total cable length, cable capacitance, shielding arrangement, and required frequency response. Longer wiring can cause high-frequency signal roll-off, so follow the applicable system documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How can a buyer confirm that a replacement cable supports the required hazardous-area installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the complete part number, approval documentation, installation drawing, and associated probe and Proximitor configuration. Do not rely on a family name or suffix alone when verifying site certification.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote | Bently Nevada 3300 XL Extension Cable\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact Global PLC Spare HUB for pricing, availability, and technical selection support for the \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e330130-085-13-05\u003c\/span\u003e\u003c\/strong\u003e. Provide your required quantity, probe model, Proximitor model, total system length, and operating environment to help confirm the correct cable configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130330930.png?v=1783069222\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013950726326,"sku":"330130-085-13-05","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-03-05_0a0a8424-0070-49a5-a0df-dd71214dd779.jpg?v=1792466109","url":"https:\/\/www.plcsparehub.com\/products\/330130-085-13-05-bently-nevada-3300-xl-armored-extension-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}