{"product_id":"330130-045-03-05-bently-nevada-3300-xl-extension-cable","title":"330130-045-03-05 Bently Nevada 3300 XL Extension Cable","description":"\u003cp\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstrumentation engineers often encounter signal attenuation and connector corrosion when routing traditional cabling across large mechanical skids. During the refit of a multi-stage centrifugal compressor train, replacing degraded intermediate wiring with the \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e restored the baseline DC voltage and eliminated erratic shaft vibration alarms. The patented TipLoc and CableLoc design guarantees mechanical integrity under high-frequency G-forces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e links proximity probes to proximitor sensors with minimal signal loss. Manufactured in the U.S.A., this armored 4.5-meter cable features superior shielding and agency approvals for hazardous zones. Every unit includes a 12-month warranty and ships within 24 to 48 hours via FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration Breakdown \u0026amp; Suffix Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e \u003cstrong\u003e330130\u003c\/strong\u003e - 3300 XL Extension Cable Assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length Suffix (-045):\u003c\/strong\u003e 4.5 meters (14.8 feet) total intermediate span\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArmor \u0026amp; Connector Option (-03):\u003c\/strong\u003e Armored cable housing with physical connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals (-05):\u003c\/strong\u003e Certified for CSA, ATEX, and IECEx hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eOperational Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand and Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e (\u003cstrong\u003e3300 XL\u003c\/strong\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter conductor (RCORE) 0.99 ± 0.15 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOuter conductor (RJACKET) 0.30 ± 0.06 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical distributed capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Mass \u0026amp; Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored assembly total mass 0.618 kg (103 g\/m density)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 2 mm (80 mils) system linear span from -1 to -17 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resilience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintains performance under 93 percent humidity for up to 56 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the armored cable maintaining clearance from high-voltage motor power lines.\u003c\/li\u003e\n\u003cli\u003eSecure the ClickLoc connectors hand-tight to prevent intermittent ground loops.\u003c\/li\u003e\n\u003cli\u003eUtilize the included connector protector instead of silicone tape if exposure to turbine lubricating oil is expected.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using a three-conductor shielded triad cable up to 305 meters maximum distance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDebugging and Maintenance Convenience\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure loop resistance using a precision multimeter to verify center and outer conductor integrity against baseline values.\u003c\/li\u003e\n\u003cli\u003eInspect armor casing for pinching or localized crushing following mechanical maintenance cycles.\u003c\/li\u003e\n\u003cli\u003eCheck proximitor output voltage to ensure the supply remains within the -23 Vdc to -26 Vdc operating window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertification Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully certified under CSA, ATEX, and IECEx standards for explosive gas atmospheres.\u003c\/li\u003e\n\u003cli\u003eCompliant with IEC standard 68-2-3 humidity endurance protocols.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Contents and Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e in factory packaging.\u003c\/li\u003e\n\u003cli\u003eConnector protector sleeve and backup silicone tape strip.\u003c\/li\u003e\n\u003cli\u003eComprehensive 12-Month Factory Warranty document.\u003c\/li\u003e\n\u003cli\u003eGlobal priority express shipping via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Application Scenarios and Diagnostic Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCritical steam and gas turbine supervisory monitoring systems.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial process compressors operating in explosive environments.\u003c\/li\u003e\n\u003cli\u003eRadial and axial shaft displacement tracking systems for large gearboxes.\u003c\/li\u003e\n\u003cli\u003eReal-time machinery diagnostics identifying rotor unbalance and fluid whirl.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can silicone tape be used on the 330130-045-03-05 cable connections near turbine bearings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: No, silicone tape is not recommended if the connection is exposed to turbine oil; use the physical connector protector instead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the exact DC resistance threshold for the center conductor on this 4.5-meter variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: The nominal center conductor resistance must measure 0.99 ± 0.15 ohms at ambient temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 330130-045-03-05 require specific power supply parameters at the monitor rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: Yes, the system requires -17.5 Vdc to -26 Vdc for nonincendive installations, or -23 Vdc to -26 Vdc when using safety barriers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum allowable cable run between the proximitor sensor and the monitor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: The maximum field wiring length is restricted to 305 meters (1,000 feet) using proper triad shielding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the armored option protect against mechanical damage on plant floors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA: The integrated stainless steel armor provides robust defense against crushing loads, sharp metal edges, and heavy foot traffic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuying Guide \u0026amp; Selection Advice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen selecting intermediate wiring for vibration monitoring loops, verify that your probe tip length and proximitor sensor generation match the \u003cstrong\u003e3300 XL\u003c\/strong\u003e platform specification. Always choose armored variants like the \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e330130-045-03-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL Extension Cable\u003c\/strong\u003e when routing cables through harsh, unmanaged industrial cable trays to guarantee long-term signal fidelity.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130_330930.png?v=1780908449\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013972385974,"sku":"330130-045-03-05","price":249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-03-05_316e987a-0d28-4925-9f1c-3af4ee6c5a3d.jpg?v=1788859417","url":"https:\/\/www.plcsparehub.com\/products\/330130-045-03-05-bently-nevada-3300-xl-extension-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}