{"product_id":"330130-045-02-00-4-5-meter-proximity-extension-cable-bently-nevada-series","title":"330130-045-02-00 4.5 Meter Proximity Extension Cable Bently Nevada Series","description":"\u003ch3\u003e\u003cstrong\u003eEngineering Overview \u0026amp; Configuration Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-045-02-00\u003c\/strong\u003e manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e is a precision-engineered extension cable designed for the \u003cstrong\u003e3300 XL\u003c\/strong\u003e eddy-current transducer framework. Serving as a crucial link between the 8 mm proximity probe and the proximitor sensor, this 4.5-meter assembly ensures minimal signal attenuation across high-frequency vibration monitoring loops. Patented \u003cstrong\u003eCableLoc\u003c\/strong\u003e and \u003cstrong\u003eTipLoc\u003c\/strong\u003e manufacturing methodologies guarantee high mechanical pull strength and structural integrity under severe industrial operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Parameter Specification Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e: 3300 XL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e: \u003cstrong\u003e330130-045-02-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Type\u003c\/strong\u003e: Proximity Transducer Extension Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Cable Length\u003c\/strong\u003e: 4.5 meters (14.8 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor DC Resistance\u003c\/strong\u003e: Center-to-center R_{CORE} =\u003cspan\u003e0.99 ± 0.15Ω\u003c\/span\u003e \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket DC Resistance\u003c\/strong\u003e: Outer-to-outer R_{JACKET} = \u003cspan\u003e0.30 ± 0.06Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Capacitance\u003c\/strong\u003e: 69.9pF\/m (21.3pF\/ft) typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight Specification\u003c\/strong\u003e: Standard cable format at 34 g\/m (0.4 oz\/ft), total mass 0.204 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration Level\u003c\/th\u003e\n\u003cth\u003ePart Option Code\u003c\/th\u003e\n\u003cth\u003eEngineering Specification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e045\u003c\/td\u003e\n\u003ctd\u003e4.5 meters total transmission path length optimized for standard rack distances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Protector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eStandard cable configuration equipped with integrated connector protector hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals \u0026amp; Certification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard non-hazardous unapproved baseline electrical configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Deployment Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify system power requirements, ensuring the proximitor receives between -17.5 Vdc and -26 Vdc.\u003c\/li\u003e\n\u003cli\u003eUtilize 3-conductor shielded triad cable (16 to 24 AWG) for field wiring extensions up to 305 meters (1,000 feet).\u003c\/li\u003e\n\u003cli\u003eApply the included silicone tape as an alternative connector protector only when the environment is completely free of turbine oil exposure.\u003c\/li\u003e\n\u003cli\u003eRoute extension cables away from high-power motor feeds to prevent electromagnetic noise coupling into the low-level signal path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; System Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitor DC gap voltage output levels, ensuring operating linear range remains within -1 to -17 Vdc ($0.25$ to $2.3$ mm target distance).\u003c\/li\u003e\n\u003cli\u003eInspect connector interfaces periodically for moisture accumulation or resistance drift caused by thermal cycling.\u003c\/li\u003e\n\u003cli\u003ePerform routine insulation resistance checks to verify that shield grounding integrity remains uncompromised across the plant lifecycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistics, Fulfillment \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage\u003c\/strong\u003e: Comprehensive 12-month manufacturer warranty included on all units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Speed\u003c\/strong\u003e: Expedited 24 to 48-hour order dispatch for stock inventory items.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal Carriers\u003c\/strong\u003e: Secure, trackable express transit managed via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight \u0026amp; Target Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Equipment\u003c\/strong\u003e: Steam turbines, heavy-duty gas compressors, centrifugal pumps, and hydro-generator shafts monitored by Bently Nevada rack systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e: Deployed extensively in power generation plants and petrochemical processing units requiring precise shaft vibration and radial displacement tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Insight\u003c\/strong\u003e: Global PLC Spare HUB technical teams highlight that sudden increases in extension cable capacitance or signal rolloff typically stem from crushed coaxial jackets rather than internal conductor fatigue. Always verify physical cable radius constraints during cabinet layout changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection \u0026amp; Cross-Reference Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Configuration\u003c\/strong\u003e: Compare with \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330130-040-13-00-bently-nevada-extension-cable\"\u003e330130-040-13-00\u003c\/a\u003e, which features a shorter 4.0-meter span and specialized hazardous area approval option codes tailored for tight cabinet retrofits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eExpert Technical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestion: Why is silicone tape not recommended for connections exposed to turbine oil?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Turbine oil breaks down the adhesive and material composition of standard silicone tape, compromising the moisture barrier and causing signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestion: What is the maximum recommended field wiring distance between the proximitor sensor and the monitor?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The maximum recommended field wiring length is 305 meters (1,000 feet) using 3-conductor shielded triad cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestion: How does changing input supply voltage affect the transducer linear range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Operating at a supply voltage more positive than -23.5 Vdc can significantly compress the active linear range of the measurement system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestion: What selection criteria should engineers check before substituting extension cable lengths?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Total system calibration relies on fixed electrical length matching; altering cable lengths without recalibrating the proximitor can introduce systemic calibration errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuestion: What does a typical DC resistance measurement of $0.99$ ohms signify?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e It confirms that the center conductor continuity across the 4.5-meter path is healthy and free from internal micro-fractures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130330930.png?v=1783069222\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013980446902,"sku":"330130-045-02-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-00-001_68598bd3-052b-440d-b748-3bdd094f5d15.jpg?v=1788158000","url":"https:\/\/www.plcsparehub.com\/products\/330130-045-02-00-4-5-meter-proximity-extension-cable-bently-nevada-series","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}