{"product_id":"330130-045-01-00-bently-nevada-3300-xl-armored-extension-cable","title":"330130-045-01-00 Bently Nevada 3300 XL Armored Extension Cable","description":"\u003ch3\u003e\u003cstrong\u003eSignal Transmission Architecture \u0026amp; Engineering Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e is a precision-engineered 4.5-meter armored extension cable designed by Bently Nevada for the industry-standard \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003c\/span\u003e 8 mm proximity transducer system. Manufactured in the U.S.A., this cable links the Proximitor sensor to the probe assembly while maintaining strict capacitance and impedance characteristics. Patented CableLoc and TipLoc technologies provide robust mechanical pull strength, safeguarding signal integrity in severe turbomachinery operating environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Suffix \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e (Complete Assembly Code)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330130\u003c\/strong\u003e — Base Model: \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 XL\u003c\/strong\u003e\u003c\/span\u003e 8 mm Extension Cable Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-045\u003c\/strong\u003e — Cable Length Option: 4.5 meters (14.8 feet) total run length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e — Connector Protector \u0026amp; Cable Option: Armored cable configuration with integrated connector protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e — Agency Approval Option: Not required (Standard industrial installation)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical, Mechanical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Domain\u003c\/th\u003e\n\u003cth\u003eTechnical Parameter\u003c\/th\u003e\n\u003cth\u003eOperational Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePhysical \u0026amp; Mass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Cable Weight\u003c\/td\u003e\n\u003ctd\u003e34 g\/m (0.4 oz\/ft) | Total Assembly: 0.204 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmored Cable Weight\u003c\/td\u003e\n\u003ctd\u003e103 g\/m (1.5 oz\/ft) | Total Assembly: 0.618 kg (Current Model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eDC Loop Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter Conductor ($R_{CORE}$)\u003c\/td\u003e\n\u003ctd\u003e0.99 ± 0.15 Ω (for 4.5 m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Conductor ($R_{JACKET}$)\u003c\/td\u003e\n\u003ctd\u003e0.30 ± 0.06 Ω (for 4.5 m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eElectrical Properties\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical distributed capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance \u0026amp; Supply\u003c\/td\u003e\n\u003ctd\u003e50 Ω output resistance; -17.5 Vdc to -26 Vdc loop power (-23 Vdc with barriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eSystem Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils); spans 0.25 mm to 2.3 mm (-1 to -17 Vdc) against AISI 4140 steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Stability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3% change in Average Scale Factor (ASF) at 93% humidity for up to 56 days (IEC 68-2-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection Comparison \u0026amp; Engineering Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvaluate the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e against alternative configurations such as \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330130-085-13-05-bently-nevada-3300-xl-armored-extension-cable\"\u003e\u003cstrong\u003e330130-085-13-05\u003c\/strong\u003e\u003c\/a\u003e to match your exact physical routing and environmental constraints:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Attribute\u003c\/th\u003e\n\u003cth\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e (Current Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330130-085-13-05-bently-nevada-3300-xl-armored-extension-cable\"\u003e\u003cstrong\u003e330130-085-13-05\u003c\/strong\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e4.5 meters (14.8 ft)\u003c\/strong\u003e (Option 045)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e8.5 meters\u003c\/strong\u003e (Option 085)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket \/ Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored cable with connector protector (Option 01)\u003c\/td\u003e\n\u003ctd\u003eArmored cable with specialized FluidLoc \/ extended sealing (Option 13)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required (Option 00)\u003c\/td\u003e\n\u003ctd\u003eHazardous area approvals included (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Calibration Rule:\u003c\/strong\u003e Bently Nevada 3300 XL systems are calibrated as a matched set. When pairing the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e (4.5m cable), ensure your probe tip cable length is 0.5 meters so that the combined electrical length equals exactly 5.0 meters to maintain mV\/mil linearity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting \u0026amp; Protection:\u003c\/strong\u003e The armored stainless steel jacket on the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e protects against mechanical chaffing on compressor skids. For applications exposed to aggressive turbine lubricating oils or synthetic fluids, evaluate FluidLoc variants like \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330130-085-13-05-bently-nevada-3300-xl-armored-extension-cable\"\u003e\u003cstrong\u003e330130-085-13-05\u003c\/strong\u003e\u003c\/a\u003e to prevent oil wick migration through the cable core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Best Practices\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAvoid using the included silicone tape on probe-to-extension cable connectors if the junction is exposed to turbine oil, as oil degrades silicone adhesion and compromises insulation.\u003c\/li\u003e\n\u003cli\u003eMaintain field wiring lengths under 305 meters (1,000 feet) using 3-conductor shielded triad cable (16 to 24 AWG) between the Proximitor sensor and the monitor rack.\u003c\/li\u003e\n\u003cli\u003eEnsure mechanical bend radii exceed minimum manufacturer thresholds to prevent distortion of the internal 75 Ω coaxial geometry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is precise DC resistance measurement (0.99 ± 0.15 Ω for $R_{CORE}$) critical when commissioning the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Deviations outside the specified resistance window indicate damaged center conductors, broken shield braids, or moisture ingress inside the coaxial dielectric, which introduces high-frequency attenuation and calibration errors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the patented CableLoc design on the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e\u003c\/span\u003e withstand heavy machine casing vibrations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: CableLoc locks the coaxial cable firmly to the connector housing, providing up to 330 N (75 lbf) of pull strength to prevent mechanical fatigue and conductor shear during continuous high-amplitude machinery oscillations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens to the system output scale factor if an incorrect extension cable length is substituted during maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Substituting mismatched cable lengths alters total circuit capacitance and RF tuning, shifting the Proximitor output voltage and invalidating the standard 200 mV\/mil sensitivity curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does Bently Nevada caution against using silicone tape on connector joints in turbine oil service?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Industrial lubricating and turbine oils break down silicone elastomer bonds, causing the tape to unwrap and allowing oil to contaminate the miniature coaxial contacts, leading to signal noise or gap voltage drift.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field wiring specifications prevent signal roll-off over long runs between the Proximitor sensor and the monitor rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Engineers should use 3-conductor tinned, shielded triad cable sized between 16 and 24 AWG, ensuring overall shield grounding is terminated exclusively at the monitor rack to reject electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130330930.png?v=1783069222\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013949841590,"sku":"330130-045-01-00","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-030-01-001_6fee778a-957e-4b80-a9b0-7c0dfd7cb3ee.jpg?v=1793159124","url":"https:\/\/www.plcsparehub.com\/products\/330130-045-01-00-bently-nevada-3300-xl-armored-extension-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}