{"product_id":"330130-040-13-00-bently-nevada-extension-cable","title":"330130-040-13-00 Bently Nevada Extension Cable","description":"\u003ch3\u003e\n\u003cb\u003e330130-040-13-00\u003c\/b\u003e Engineering Architecture \u0026amp; Signal Transmission Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e precision extension cable assembly from \u003cb\u003eBently Nevada\u003c\/b\u003e is engineered to link 3300 XL proximity probes with Proximitor sensors in high-demand rotating machinery. Operating within the renowned \u003cb\u003e\u003cb\u003e3300 XL Series\u003c\/b\u003e\u003c\/b\u003e ecosystem, this 4.0-meter armored cable maintains precise electrical resistance (RCORE and RJACKET) and minimal capacitance, ensuring signal fidelity for vibration monitoring, shaft displacement, and phase reference measurements.\u003c\/p\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: In high-vibration turbomachinery applications where oil mist and mechanical stress threaten signal integrity, deploying the \u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e with its Armored FluidLoc jacket prevents oil migration through the cable core while protecting sensitive eddy-current signals from high-frequency electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cb\u003e330130-040-13-00\u003c\/b\u003e Configuration Breakdown \u0026amp; Model Suffix Tree\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%; border-color: #d1d5db;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f3f4f6;\"\u003e\n\u003cth style=\"text-align: left;\"\u003ePart Number Code\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eEngineering Parameter Definition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e (Base Series)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eBently Nevada\u003c\/b\u003e \u003cb\u003e\u003cb\u003e3300 XL Extension Cable\u003c\/b\u003e\u003c\/b\u003e Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCable Length (040)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (11.5 feet) precise physical length option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector Protector \u0026amp; Jacket (13)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored FluidLoc cable incorporating a robust connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eApprovals (00)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard hazardous area classification (Not required \/ Non-classified option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePhysical Weight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eArmored extension cable net weight of 0.618 kg (103 g\/m density)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand \u0026amp; Model\u003c\/b\u003e: \u003cb\u003eBently Nevada\u003c\/b\u003e \u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e (\u003cb\u003e\u003cb\u003e3300 XL Series\u003c\/b\u003e\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConductor DC Resistance (RCORE)\u003c\/b\u003e: 0.88 ± 0.13 Ω from center conductor to center conductor across 4.0 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eJacket DC Resistance (RJACKET)\u003c\/b\u003e: 0.26 ± 0.05 Ω from outer conductor to outer conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExtension Cable Capacitance\u003c\/b\u003e: 69.9 pF\/m (21.3 pF\/ft) typical distributed capacitance\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystem Linear Range\u003c\/b\u003e: 2 mm (80 mils) spanning from 0.25 mm to 2.3 mm from target\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Diagnostics \u0026amp; Signal Integrity Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCore Resistance Supervision\u003c\/b\u003e: Monitoring RCORE stability helps technicians identify micro-cracks or pinches in the coaxial core before signal attenuation causes false vibration spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCapacitive Load Management\u003c\/b\u003e: Strict adherence to the 69.9 pF\/m capacitance threshold prevents phase distortion and high-frequency signal rolloff across extended monitoring loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShield Grounding Protection\u003c\/b\u003e: The outer braided jacket maintains low-impedance shielding to suppress electrical noise induced by adjacent high-voltage motor windings and variable frequency drives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Equipment Compatibility \u0026amp; Industrial Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCompatible Hardware\u003c\/b\u003e: 3300 XL 8 mm proximity probes, Proximitor sensors, and 3-conductor shielded triad field wiring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eApplication Scenarios\u003c\/b\u003e: Steam turbine generator sets, heavy-duty gas compressors, centrifugal pumps, and hydroelectric turbine shaft vibration monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty, Packaging \u0026amp; Express Logistics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging Details\u003c\/b\u003e: Factory-coiled \u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e cable assembly complete with connector protector and installation accessories.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQuality Assurance\u003c\/b\u003e: Backed by a full 12-month commercial warranty covering electrical and material defects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGlobal Shipping\u003c\/b\u003e: 24 to 48-hour expedited fulfillment via \u003cb\u003eFedex\u003c\/b\u003e, \u003cb\u003eUPS\u003c\/b\u003e, and \u003cb\u003eDHL\u003c\/b\u003e global logistics networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guide \u0026amp; Engineering Comparison\u003c\/h3\u003e\n\u003cp\u003eWhen engineering vibration monitoring loops, matching extension cable impedance and length to your Proximitor sensor calibration is paramount. The \u003cb\u003e\u003cb\u003e330130-040-13-00\u003c\/b\u003e\u003c\/b\u003e provides an armored, fluid-sealed 4-meter connection tailored for oil-immersed or mechanically harsh pathways. Instrument engineers must verify that total system length (probe plus extension cable plus field wiring) aligns with the manufacturer's frequency response curves to avoid high-frequency attenuation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: Why is silicone tape not recommended for connector protection when exposed to turbine oil?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Turbine oil can degrade standard silicone tape adhesives over time, compromising the moisture seal at the probe-to-extension cable junction; mechanical connector protectors or FluidLoc designs should be utilized instead.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How does the FluidLoc design prevent oil leakage from machinery casings?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The internal cable structure incorporates a specialized barrier that blocks capillary action, preventing lubricating oil from migrating through the interior strands and out of the machine housing.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What is the maximum recommended field wiring length between the Proximitor sensor and the monitor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field wiring can extend up to 305 meters (1,000 feet) using 3-conductor shielded triad cable, though engineers must account for signal rolloff at high frequencies over maximum distances.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: How do environmental humidity fluctuations impact the average scale factor of the transducer system?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The system experiences less than a 3% change in Average Scale Factor when exposed to up to 93% humidity for 56 days, ensuring reliable performance in humid industrial atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: What precautions should be taken regarding power supply voltage during installation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The system requires -17.5 Vdc to -26 Vdc power; operating at voltages more positive than -23.5 Vdc can result in a reduced linear measurement range and compromised vibration data accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130330930.png?v=1783069222\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013972418742,"sku":"330130-040-13-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-03-05_9d342689-ba6c-4b7c-b5f6-0cbdb647815a.jpg?v=1787731108","url":"https:\/\/www.plcsparehub.com\/products\/330130-040-13-00-bently-nevada-extension-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}