{"product_id":"330130-035-12-00-bently-nevada-3300-xl-fluidloc-extension-cable","title":"330130-035-12-00 Bently Nevada 3300 XL FluidLoc Extension Cable","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e330130-035-12-00\u003c\/span\u003e\u003c\/b\u003e is a premium 3.5-meter industrial extension cable engineered for the \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e3300 XL\u003c\/span\u003e\u003c\/b\u003e proximity transducer series. Manufactured in the United States, this component acts as the high-integrity electrical link between an eddy current proximity probe and a Proximitor sensor module. It features advanced FluidLoc internal sealing technology to prevent machine oils from migrating through the cable interior, paired with a heavy-duty mechanical connector protector for harsh deployment zones.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eConfiguration Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe part number \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e330130-035-12-00\u003c\/span\u003e\u003c\/b\u003e is mapped via the following structured configuration breakdown:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBase Model (330130):\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e3300 XL\u003c\/span\u003e\u003c\/b\u003e Standard Extension Cable System\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Length Option (035):\u003c\/b\u003e 3.5 meters (11.5 feet) nominal length\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConnector Protector and Cable Option (12):\u003c\/b\u003e FluidLoc cable layout equipped with an integrated connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAgency Approval Option (00):\u003c\/b\u003e No specific regional hazardous area approvals required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand:\u003c\/b\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModel Number:\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e330130-035-12-00\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct Type:\u003c\/b\u003e Transducer Extension Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystem Compatibility:\u003c\/b\u003e Interfaces with 3300-series 5 mm, 8 mm, and \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e3300 XL\u003c\/span\u003e\u003c\/b\u003e 8 mm proximity probes\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCore Line Capacitance:\u003c\/b\u003e 69.9 pF\/m (21.3 pF\/ft) typical capacitance rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCenter Conductor Resistance (RCORE):\u003c\/b\u003e 0.77 ± 0.12 Ω across the 3.5-meter span\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOuter Jacket Resistance (RJACKET):\u003c\/b\u003e 0.23 ± 0.05 Ω shielding loop resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMechanical Interface:\u003c\/b\u003e Corrosion-resistant, gold-plated ClickLoc coaxial connectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePhysical Mass:\u003c\/b\u003e Unarmored variant rated at 34 g\/m (0.4 oz\/ft) with a total baseline weight of 0.204 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystem Linear Range:\u003c\/b\u003e 2 mm (80 mils) total span when matched with an 8 mm probe assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystem Operating Power:\u003c\/b\u003e Requires -17.5 Vdc to -26 Vdc at 12 mA maximum current draw\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSupply Sensitivity:\u003c\/b\u003e Less than 2 mV output shift per Volt variation on the main input line\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Impedance:\u003c\/b\u003e 50 Ω nominal signal output resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental Moisture Resistance:\u003c\/b\u003e Under 3% shift in Average Scale Factor (ASF) after 56 days in 93% humidity per IEC 68-2-3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eField Wiring \u0026amp; Measurement Boundaries\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eField Wiring Specifications:\u003c\/b\u003e Compatible with cross-sections from 0.2 to 1.5 mm² (16 to 24 AWG)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Architecture Recommendation:\u003c\/b\u003e Structured 3-conductor shielded triad cable using tinned field wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum Driver Distance:\u003c\/b\u003e Supports a maximum length of 305 meters (1,000 feet) between Proximitor sensor and monitor\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLinear Zone Parameters:\u003c\/b\u003e Begins 0.25 mm (10 mils) from target; runs from 0.25 to 2.3 mm (10 to 90 mils) at –1 to –17 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStandard Calibration Target:\u003c\/b\u003e Fully verified using premium AISI 4140 steel targets between +18°C and +27°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eVibration Loop Diagnostic Capabilities\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFluid-Migration Isolation:\u003c\/b\u003e FluidLoc core structure isolates high-pressure turbine oil spaces from control rooms\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eClickLoc Continuity Verification:\u003c\/b\u003e Gold-plated coaxial interfaces resist oxidation to eliminate signal loss diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLinear Span Validation:\u003c\/b\u003e Systems flag calibration drift if driver supply drops more positive than -23.5 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShield Loop Continuity:\u003c\/b\u003e Defined jacket resistance limits allow real-time detection of shield degradation or tearing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSuitable Equipment \u0026amp; Application Scenarios\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCritical Turbo-Machinery:\u003c\/b\u003e Boiler feed pumps, industrial gas turbines, steam turbine generator trains, and large-scale compressors\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThrust and Radial Monitoring:\u003c\/b\u003e High-vibration environments requiring precise shaft position and fluid-film bearing telemetry\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOil-Immersed Enclosures:\u003c\/b\u003e Ideal for monitoring points located inside internal gearboxes or oil-wetted bearing blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e330130-035-12-00\u003c\/span\u003e\u003c\/b\u003e provides exceptional protection against capillary oil migration. In many turbine applications, oil seeps through standard stranded cables, eventually damaging external terminal boxes or Proximitor driver stages. By selecting the Option 12 FluidLoc model, you deploy a physical internal block against fluid wicking. The integrated connector protector provides much higher physical strain relief than standard silicone tape wraps, ensuring stable impedance loops across the gold-plated ClickLoc joints during long-term machinery operations.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eLogistics, Warranty, \u0026amp; Package Details\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Policy:\u003c\/b\u003e Includes a full 12-month factory comprehensive performance warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress Shipping Networks:\u003c\/b\u003e International global tracking provided via DHL, FedEx, and UPS\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHandling Timeline:\u003c\/b\u003e Orders are processed, packed, and dispatched from stock within 24 to 48 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCondition Status:\u003c\/b\u003e Guaranteed New \u0026amp; Original condition contained inside official factory packaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSelection Comparison \u0026amp; Technical Advice\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen selecting your \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e3300 XL\u003c\/span\u003e\u003c\/b\u003e infrastructure, compare your field layout requirements to alternative configurations in stock:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent Model:\u003c\/b\u003e \u003cb\u003e\u003cspan style=\"color: #007bff;\"\u003e330130-035-12-00\u003c\/span\u003e\u003c\/b\u003e — Features a 3.5-meter length, integrated FluidLoc oil blocking, and built-in connector protection. Ideal for mid-length routing through areas with direct turbine oil exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAlternative Model:\u003c\/b\u003e \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/bently-nevada-330130-060-00-05-proximity-extension-cable-3300-xl\" target=\"_blank\"\u003e330130-060-00-05\u003c\/a\u003e — Features a longer 6.0-meter unarmored length, standard non-FluidLoc cable, and global agency approvals (Option 05).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eTechnical Recommendation:\u003c\/b\u003e Always match your total system length profile (typically 5.0 meters or 9.0 meters total) combining probe and extension cable. Mixing a 3.5-meter extension with an incompatible probe length will alter system capacitance and invalidate the calibration scale factor. Use the FluidLoc option (Option 12) if the cable routes through oil-wetted machinery walls; use the standard unarmored option if routing through standard external conduit runs.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eWhat operational failure does the internal FluidLoc technology prevent?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFluidLoc blocks internal siphoning, preventing pressurized lube oil from leaking out of the machine housing through the cable strands.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCan I substitute standard electrical tape for the included silicone tape wraps?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo, typical electrical tapes break down rapidly when exposed to hot turbine lubricants, leading to connector contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHow does an extension cable length option of 3.5 meters impact my total transducer setup?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA 3.5-meter cable must be matched with a corresponding 1.5-meter proximity probe to maintain the target 5.0-meter electrical tuning loop.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhat occurs if the environmental operating altitude of this system exceeds 2,000 meters?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eOperation above 2,000 meters may require derating of insulation and thermal parameters due to reduced atmospheric density.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWhy is the outer jacket electrical resistance (RJACKET) tracking parameter critical?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA change in jacket resistance beyond the 0.23 ± 0.05 Ω window indicates shielding breakdown, which can introduce external noise into the vibration signal.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013991948470,"sku":"330130-035-12-00","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330130-035-00-001_1053170d-ceba-4a86-86ca-fcd604d3c2c6.jpg?v=1782724008","url":"https:\/\/www.plcsparehub.com\/products\/330130-035-12-00-bently-nevada-3300-xl-fluidloc-extension-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}