{"product_id":"330106-05-30-05-02-br-reverse-mount-probe-bently-nevada-3300-xl","title":"330106-05-30-05-02-BR Reverse Mount Probe | Bently Nevada 3300 XL","description":"\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e330106-05-30-05-02-BR\u003c\/span\u003e\u003c\/strong\u003e is a cornerstone of industrial vibration monitoring. Our engineers at Global PLC Spare HUB recognize its 3300 XL platform for providing exceptional linearity and thermal stability in extreme environments. Unlike standard probes, the PPS tip and stainless steel construction ensure long-term reliability in the presence of synthetic lube oils and high-pressure steam, making it the preferred choice for primary journal position and radial vibration measurements.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #d32f2f;\"\u003e330106\u003c\/span\u003e\u003c\/strong\u003e: 3300 XL 8mm Reverse Mount Probe\n\u003cul\u003e\n\u003cli\u003eTotal Length: -05 (0.5 meter)\u003c\/li\u003e\n\u003cli\u003eConnector Option: -02 (Miniature ClickLoc coaxial)\u003c\/li\u003e\n\u003cli\u003eAgency Approval: -BR (Country Specific)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProbe Tip: Polyphenylene sulfide (PPS) for chemical resistance.\u003c\/li\u003e\n\u003cli\u003eCase Material: AISI 303\/304 Stainless Steel (M10x1 Threading).\u003c\/li\u003e\n\u003cli\u003eCable Type: 75Ω Triaxial with FEP insulation.\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -52 °C to +177 °C (-62 °F to +350 °F).\u003c\/li\u003e\n\u003cli\u003ePressure Rating: Designed for differential pressure sealing via Viton® O-ring.\u003c\/li\u003e\n\u003cli\u003eDC Resistance: 7.45 Ω ± 0.50 Ω.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication \u0026amp; Diagnostic Capabilities\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTarget Equipment: High-speed centrifugal compressors, steam turbines, and hydro-electric generators.\u003c\/li\u003e\n\u003cli\u003eMonitoring Functions: Journal shaft position, shaft vibration (radial), and thrust position.\u003c\/li\u003e\n\u003cli\u003eDiagnostic Power: Enables precise analysis of shaft orbital behavior, detecting sub-synchronous instability, misalignment, and potential bearing wipe-out.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWarranty: 12-month manufacturer quality assurance coverage.\u003c\/li\u003e\n\u003cli\u003eShipping: Expedited global shipping via FedEx, UPS, or DHL with 24-48 hour dispatch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow critical is the -34°C (-30°F) temperature limit regarding the pressure seal?\u003c\/strong\u003e\u003cbr\u003eExposing the probe to temperatures below this threshold can induce brittle failure in the Viton O-ring, leading to potential oil leakage into the machine casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy should I choose the ClickLoc connector over standard options?\u003c\/strong\u003e\u003cbr\u003eThe ClickLoc connector is designed to provide consistent electrical contact impedance, preventing signal \"noise\" that can be introduced by loose or oxidized threaded connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the PPS tip susceptible to damage from high-velocity oil flow?\u003c\/strong\u003e\u003cbr\u003eNo, PPS is highly resilient to hydraulic erosion, though care should be taken to mount the probe so the tip is not subject to direct high-velocity impingement from oil jets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this probe be used in hazardous area applications?\u003c\/strong\u003e\u003cbr\u003eThe -BR suffix denotes country-specific approvals; verify your local regulatory compliance (ATEX\/IECEx\/CSA) against the specific certification data provided with your unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow do I troubleshoot if my DC resistance readings deviate from 7.45 Ω?\u003c\/strong\u003e\u003cbr\u003eSignificant deviations indicate a compromised cable shield or an internal fracture in the triaxial cable; the probe must be replaced to prevent erroneous gap voltages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guidance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the M10x1 mounting hole is clean and free of burrs to prevent damage to the probe case threading during installation.\u003c\/li\u003e\n\u003cli\u003eIf your application requires frequent thermal cycling, consider upgrading to the Extended Temperature Range cable option to preserve signal integrity.\u003c\/li\u003e\n\u003cli\u003eAlways maintain the probe tip distance within the specified linear range to ensure valid eddy-current output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330105_330106_330f090f-74f7-4f64-9ae1-fc86402905ed.png?v=1781601845\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014037233846,"sku":"330106-05-30-05-02-BR","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330106_5.jpg?v=1782891231","url":"https:\/\/www.plcsparehub.com\/products\/330106-05-30-05-02-br-reverse-mount-probe-bently-nevada-3300-xl","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}