{"product_id":"330104-15-23-10-02-00-proximity-probe-3300-xl-8mm-bently-nevada","title":"330104-15-23-10-02-00 Proximity Probe 3300 XL 8mm Bently Nevada","description":"\u003ch3\u003e\u003cb\u003eTransducer Architecture \u0026amp; Mechanical Profile: \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eBently Nevada 330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e is an armored metric eddy-current transducer engineered within the \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e3300 XL 8 mm\u003c\/b\u003e\u003c\/span\u003e proximity probe platform. Configured with a \u003cb\u003e150 mm unthreaded tip section\u003c\/b\u003e and a \u003cb\u003e230 mm overall case length\u003c\/b\u003e, this \u003cb\u003eM10 × 1\u003c\/b\u003e threaded probe reaches deeply recessed journal bearings and turbine shaft targets while maintaining rigid mechanical support. Coupled with a \u003cb\u003e1.0-meter\u003c\/b\u003e integral coaxial cable and miniature \u003cb\u003eClickLoc\u003c\/b\u003e connector, it delivers a \u003cb\u003e2.0 mm (80 mils)\u003c\/b\u003e linear measurement range for radial vibration, axial thrust position, and Keyphasor reference monitoring on critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePart Number Configuration Tree\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEach option code in \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e specifies exact dimensional geometry, cable assembly length, and certification tier:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104\u003c\/b\u003e\u003c\/span\u003e — Base Model: \u003cb\u003e3300 XL 8 mm Proximity Probe\u003c\/b\u003e, \u003cb\u003eM10 × 1\u003c\/b\u003e metric thread, with stainless steel armor\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e-15\u003c\/b\u003e — Unthreaded Length Option: \u003cb\u003e150 mm\u003c\/b\u003e smooth tip section (prevents thread binding in deep bores)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-23\u003c\/b\u003e — Overall Case Length Option: \u003cb\u003e230 mm\u003c\/b\u003e total probe barrel length\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-10\u003c\/b\u003e — Total Cable Length Option: \u003cb\u003e1.0 meter (3.3 feet)\u003c\/b\u003e integral coaxial lead\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-02\u003c\/b\u003e — Connector \u0026amp; Cable Option: Miniature \u003cb\u003eClickLoc\u003c\/b\u003e coaxial connector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e-00\u003c\/b\u003e — Agency Approval Option: Not required (standard industrial build)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eElectrical, Metrological \u0026amp; Mechanical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eReference the engineering parameters below when validating loop resistance, static gap voltage, and mechanical mounting torque:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cb\u003eSubsystem\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cb\u003eEngineering Parameter\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cb\u003eSpecification Value \/ Rating\u003c\/b\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIdentification\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer \u0026amp; Part Number\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003eBently Nevada\u003c\/b\u003e\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e (\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e3300 XL 8 mm\u003c\/b\u003e\u003c\/span\u003e Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMetrology\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e2.0 mm (80 mils)\u003c\/b\u003e total span: \u003cb\u003e0.25 to 2.3 mm (10 to 90 mils)\u003c\/b\u003e (~ -1 to -17 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMetrology\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended Radial Gap Setting\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-9 Vdc\u003c\/b\u003e [approximately \u003cb\u003e1.27 mm (50 mils)\u003c\/b\u003e from shaft target]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eElectrical Loop\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eNominal Probe DC Resistance (1.0 m)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e7.59 ± 0.50 Ω\u003c\/b\u003e (center conductor to outer shield R\u003csub\u003ePROBE\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eField Wiring\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eProximitor-to-Monitor Cabling\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e0.2 to 1.5 mm² (16–24 AWG)\u003c\/b\u003e 3-conductor shielded triad; \u003cb\u003e305 m (1,000 ft)\u003c\/b\u003e max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMaterials \u0026amp; Seal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTip, Case \u0026amp; Pressure Seal\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003ePPS\u003c\/b\u003e tip | \u003cb\u003eAISI 303 or 304 SST\u003c\/b\u003e case | \u003cb\u003eViton® O-ring\u003c\/b\u003e differential pressure seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMechanical\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eThread Size, Engagement \u0026amp; Mass\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003eM10 × 1\u003c\/b\u003e thread | Max thread engagement: \u003cb\u003e15 mm\u003c\/b\u003e | Linear mass: \u003cb\u003e323 g\/m (11.4 oz)\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTorque Limits\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eForward-Mounted Case Torque\u003c\/td\u003e\n\u003ctd\u003eRecommended: \u003cb\u003e11.2 N·m (100 in·lbf)\u003c\/b\u003e | Maximum rated: \u003cb\u003e33.9 N·m (300 in·lbf)\u003c\/b\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEnvironment\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating \/ Storage Temperature\u003c\/td\u003e\n\u003ctd\u003eStandard: \u003cb\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/b\u003e (Extended tip rating up to +218°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHumidity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEnvironmental Stability (IEC 68-2-3)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e\u0026lt; 3% change\u003c\/b\u003e in Average Scale Factor (ASF) after 56 days at 93% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eModel Selection Comparison \u0026amp; Engineering Guidance\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEvaluate \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e alongside \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330104-00-05-05-11-05-bently-nevada-3300-xl-8mm-proximity-probe\"\u003e\u003cb\u003e330104-00-05-05-11-05\u003c\/b\u003e\u003c\/a\u003e to align probe barrel length, cable termination, and hazardous-area approvals with your machine train:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cb\u003eSelection Criterion\u003c\/b\u003e\u003c\/th\u003e\n\u003cth\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e (This Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330104-00-05-05-11-05-bently-nevada-3300-xl-8mm-proximity-probe\"\u003e\u003cb\u003e330104-00-05-05-11-05\u003c\/b\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUnthreaded \/ Case Length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e150 mm\u003c\/b\u003e unthreaded \/ \u003cb\u003e230 mm\u003c\/b\u003e overall case\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e0 mm\u003c\/b\u003e unthreaded \/ \u003cb\u003e50 mm\u003c\/b\u003e overall case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eTotal Integral Cable Length\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e1.0 meter (3.3 feet)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 meter (20 inches)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector \u0026amp; Cable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-02:\u003c\/b\u003e Miniature ClickLoc coaxial connector, standard cable\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-11:\u003c\/b\u003e Miniature ClickLoc connector with \u003cb\u003eFluidLoc\u003c\/b\u003e oil-sealed cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAgency Approvals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-00:\u003c\/b\u003e Not required (unclassified area)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb\u003e-05:\u003c\/b\u003e Multiple hazardous-area approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eTechnical Selection Recommendation:\u003c\/b\u003e Select \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e330104-15-23-10-02-00\u003c\/b\u003e\u003c\/span\u003e for deep-reach bearing housing penetrations requiring a \u003cb\u003e230 mm barrel\u003c\/b\u003e with a \u003cb\u003e150 mm unthreaded snout\u003c\/b\u003e in standard non-hazardous industrial zones. Choose \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330104-00-05-05-11-05-bently-nevada-3300-xl-8mm-proximity-probe\"\u003e\u003cb\u003e330104-00-05-05-11-05\u003c\/b\u003e\u003c\/a\u003e when mounting in shallow \u003cb\u003e50 mm\u003c\/b\u003e brackets inside Zone 0\/1\/2 hazardous locations where pressurized lube oil demands \u003cb\u003eFluidLoc\u003c\/b\u003e cable sealing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eHazardous Area Reference (3300 XL Series Architecture)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIntrinsic Safety (Ex ia):\u003c\/b\u003e When ordered with agency approvals and wired via Zener barriers (Drawing 141092) or galvanic isolators, the \u003cspan style=\"color: #0056b3;\"\u003e\u003cb\u003e3300 XL\u003c\/b\u003e\u003c\/span\u003e probe platform supports \u003cb\u003eClass I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga\u003c\/b\u003e and Class I\/II\/III Division 1 groups (T1 to T5 ambient ratings from -55°C up to +232°C).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNonincendive \/ Increased Safety (Ex nA \/ ec):\u003c\/b\u003e When connected per Drawing 140979, approved variants comply with \u003cb\u003eClass I, Zone 2: AEx\/Ex nA \/ ec IIC T5...T1 Gc\u003c\/b\u003e and Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Commissioning Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eExtension Cable System Matching:\u003c\/b\u003e Pair this \u003cb\u003e1.0 m\u003c\/b\u003e probe strictly with a matching \u003cb\u003e3300 XL\u003c\/b\u003e extension cable (4.0 m or 8.0 m) so total electrical length equals the exact \u003cb\u003e5.0 m\u003c\/b\u003e or \u003cb\u003e9.0 m\u003c\/b\u003e calibration of your \u003cb\u003e3300 XL Proximitor Sensor\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStatic Gapping \u0026amp; Torque Control:\u003c\/b\u003e Thread the \u003cb\u003eM10 × 1\u003c\/b\u003e barrel to achieve a static gap output of \u003cb\u003e-9.0 Vdc (~1.27 mm \/ 50 mils)\u003c\/b\u003e, engage no more than \u003cb\u003e15 mm\u003c\/b\u003e of thread length, and tighten the locknut to \u003cb\u003e11.2 N·m (100 in·lbf)\u003c\/b\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow-Temperature Seal Precaution:\u003c\/b\u003e Avoid exposing the Viton® pressure seal to continuous temperatures below \u003cb\u003e-34°C (-30°F)\u003c\/b\u003e in pressurized differential applications to prevent elastomer hardening and premature seal leakage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eField Engineering FAQ\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: What resistance reading confirms coil and cable continuity on the 330104-15-23-10-02-00 during loop checks?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Measure DC resistance between the miniature ClickLoc center conductor and outer shield; a properly functioning 1.0 m probe measures 7.59 ± 0.50 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: Why does this probe specify a 150 mm unthreaded length within its 230 mm overall case?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 150 mm unthreaded forward section allows the probe tip to pass through thick bearing pedestals or unthreaded clearance bores without galling threads, while keeping thread engagement within the 15 mm maximum limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: Can this -00 agency option probe be installed in a Class I, Division 2 or Zone 0 hazardous area?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, although the 3300 XL series supports Ex ia and Ex nA\/ec certifications when ordered with agency approval options (such as -05), the -00 suffix designates an uncertified build restricted to non-hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: What happens to high-frequency vibration signals when field wiring between the Proximitor and monitor approaches 305 meters?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field runs up to 305 meters (1,000 feet) using 16–24 AWG shielded triad cable remain within specification, but increased line capacitance causes predictable high-frequency signal rolloff at upper kilohertz frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eQ: Are 3300 XL 8 mm probes pressure-tested at the factory for differential pressure applications?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, while the internal Viton® O-ring is engineered to seal differential pressure between the PPS tip and stainless steel case, units are not hydrostatically or pneumatically pressure-tested prior to shipment unless custom factory testing is requested.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013949153462,"sku":"330104-15-23-10-02-00","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330104_23.jpg?v=1789983817","url":"https:\/\/www.plcsparehub.com\/products\/330104-15-23-10-02-00-proximity-probe-3300-xl-8mm-bently-nevada","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}