{"product_id":"330104-00-24-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe-best-price","title":"330104-00-24-05-02-00 Bently Nevada 3300 XL 8mm Proximity Probe Best Price","description":"\u003ch3\u003eVibration Monitoring \u0026amp; Sensor Architecture Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330104-00-24-05-02-00\u003c\/strong\u003e \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e3300 XL\u003c\/strong\u003e 8 mm proximity probe delivers precision eddy-current measurement for high-speed rotating machinery. Designed for harsh industrial turbine environments, this transducer system measures radial vibration, axial position, and rotor dynamics with high linearity and thermal stability.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown Tree\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase Model \u0026amp; Series: \u003cstrong\u003e330104\u003c\/strong\u003e (3300 XL 8 mm Probe, M10 x 1 thread, with armor)\n\u003cul\u003e\n\u003cli\u003eUnthreaded Length Option: \u003cstrong\u003e00\u003c\/strong\u003e (00 mm unthreaded length)\u003c\/li\u003e\n\u003cli\u003eOverall Case Length Option: \u003cstrong\u003e24\u003c\/strong\u003e (240 mm case length)\u003c\/li\u003e\n\u003cli\u003eTotal Cable Length Option: \u003cstrong\u003e05\u003c\/strong\u003e (0.5 meter \/ 1.6 feet length)\u003c\/li\u003e\n\u003cli\u003eConnector \u0026amp; Cable Type Option: \u003cstrong\u003e02\u003c\/strong\u003e (Miniature coaxial ClickLoc connector, standard cable)\u003c\/li\u003e\n\u003cli\u003eAgency Approval Option: \u003cstrong\u003e00\u003c\/strong\u003e (Not required \/ standard hazardous area rating profile)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Category\u003c\/th\u003e\n\u003cth\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST) with Viton O-ring seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximitor Input \u0026amp; Power\u003c\/td\u003e\n\u003ctd\u003eAccepts one 3300-series 5mm\/8mm probe; requires -17.5 Vdc to -26 Vdc (12 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Sensitivity \u0026amp; Output\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 mV output change per volt change; output resistance 50 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Probe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.45 ± 0.50 Ohms (Center conductor to outer conductor for 0.5m length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Target \u0026amp; Gap\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel target at 1.27 mm (50 mils) operational gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Setup Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure machine shutdown and lock out system power before installing the \u003cstrong\u003e330104-00-24-05-02-00\u003c\/strong\u003e probe into bearing housings.\u003c\/li\u003e\n\u003cli\u003eApply thread sealant cautiously to the M10 x 1 threaded probe case without contaminating the PPS sensing tip.\u003c\/li\u003e\n\u003cli\u003eThread the probe into the mounting hole until the static gap distance reaches the recommended 1.27 mm baseline.\u003c\/li\u003e\n\u003cli\u003eLock the jam nut securely to prevent mechanical loosening caused by continuous machinery vibration.\u003c\/li\u003e\n\u003cli\u003eConnect the ClickLoc miniature coaxial connector to the extension cable, ensuring a tight, twist-lock engagement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMachinery Diagnostic Capabilities \u0026amp; Monitoring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRotor Vibration Tracking: Captures high-frequency shaft orbit and radial vibration displacement waveforms.\u003c\/li\u003e\n\u003cli\u003eThrust Position Detection: Monitors axial shaft displacement to prevent catastrophic internal rubbing.\u003c\/li\u003e\n\u003cli\u003eSignal Integrity Verification: DC resistance checks across the coaxial line instantly flag internal short circuits or open cables.\u003c\/li\u003e\n\u003cli\u003eTransient Event Analysis: High frequency response tracks startup and shutdown critical speed resonances accurately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Industrial Equipment \u0026amp; Application Scenarios\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy steam and gas turbine generator sets in power generation plants.\u003c\/li\u003e\n\u003cli\u003eLarge centrifugal and axial compressors across petrochemical refining facilities.\u003c\/li\u003e\n\u003cli\u003eMulti-stage industrial boiler feed pumps and high-speed motor drives.\u003c\/li\u003e\n\u003cli\u003eCritical hydro-turbine shafts requiring continuous non-contacting vibration telemetry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance, Logistics, \u0026amp; Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesign Standards: Engineered to meet API 670 standards for machinery protection systems\u003c\/li\u003e\n\u003cli\u003eOperating Profile: 32...140 °F (0...60 °C) temperature range, up to 2000 meters altitude\u003c\/li\u003e\n\u003cli\u003eStorage Tolerance: -40...185 °F (-40...85 °C) environment rating\u003c\/li\u003e\n\u003cli\u003eLogistics Support: Express global dispatch via FedEx, UPS, and DHL within 24-48 hours\u003c\/li\u003e\n\u003cli\u003eWarranty Protection: Backed by a full 12-month manufacturing defect replacement warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight \u0026amp; Field Experience\u003c\/h3\u003e\n\u003cp\u003eWhen replacing proximity sensors on high-vibration turbomachinery, instrumentation engineers frequently overlook the critical importance of matching total system cable length. The \u003cstrong\u003e330104-00-24-05-02-00\u003c\/strong\u003e utilizes a 0.5-meter integral probe cable, which must be paired with the correct extension cable and Proximitor sensor calibration (typically calibrated as a 5-meter or 9-meter total system) to maintain the precise scale factor of 7.87 V\/mm (200 mV\/mil). Our field experience indicates that grounding shield loops at only one end prevents ground loops from inducing high-frequency noise into the vibration monitoring rack.\u003c\/p\u003e\n\u003ch3\u003eModel Selection Comparison \u0026amp; Technical Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen evaluating alternative configurations for your specific machinery layout, compare this unit with the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330104-10-16-05-01-00-bently-nevada-3300-xl-series-proximity-sensor\"\u003e330104-10-16-05-01-00\u003c\/a\u003e model. While both belong to the trusted \u003cstrong\u003eBently Nevada\u003c\/strong\u003e \u003cstrong\u003e3300 XL\u003c\/strong\u003e series, the alternative model features a different unthreaded length option (10 mm) and overall case length option (160 mm) along with agency approvals, making it suitable for tighter mounting constraints where standard 240mm probes exceed available mechanical envelope depths.\u003c\/p\u003e\n\u003ch3\u003eProfessional Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the ClickLoc connector design prevent signal degradation in high-vibration environments?\u003c\/strong\u003e\u003cbr\u003eA: The ClickLoc mechanism locks securely to prevent thermal expansion or machine vibration from loosening the coaxial connection and causing erratic voltage spikes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific troubleshooting step should I take if the Proximitor output voltage drifts out of linear range?\u003c\/strong\u003e\u003cbr\u003eA: Verify that your power supply voltage is not dropping below -23.5 Vdc under load, and check that the static gap is precisely set to 1.27 mm against an AISI 4140 steel target.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the PPS probe tip withstand exposure to synthetic lubricating oils and high temperatures?\u003c\/strong\u003e\u003cbr\u003eA: Yes, Polyphenylene sulfide (PPS) offers exceptional chemical resistance against standard turbine lube oils and operates reliably up to 140 °F ambient.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What key factors determine whether I need agency-approved hazardous area options for this probe?\u003c\/strong\u003e\u003cbr\u003eA: Review your plant safety classification; if the sensor installs inside a Class 1 Division 2 or Zone 0\/1 hazardous atmosphere, select a configuration with appropriate intrinsic safety approvals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is measuring the DC resistance across the probe center conductor important during maintenance?\u003c\/strong\u003e\u003cbr\u003eA: Measuring a consistent DC resistance of 7.45 Ohms ensures the inner coil and coaxial shield remain intact without micro-fractures caused by metal fatigue.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014030024886,"sku":"330104-00-24-05-02-00","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330104_2_cd6f2b38-214f-4656-bb6f-19b5d277c1f0.jpg?v=1786954659","url":"https:\/\/www.plcsparehub.com\/products\/330104-00-24-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe-best-price","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}