{"product_id":"330104-00-05-05-11-05-bently-nevada-3300-xl-8mm-proximity-probe","title":"330104-00-05-05-11-05 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003eEngineering Architecture Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330104-00-05-05-11-05\u003c\/span\u003e\u003c\/strong\u003e is an advanced \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e3300 XL 8 mm Proximity Probe\u003c\/span\u003e\u003c\/strong\u003e engineered by \u003cstrong\u003e\u003cspan style=\"color: #2b303a;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e. Built with integral stainless steel armor and metric threading, this eddy-current transducer delivers high-precision vibration and displacement tracking across industrial rotating machinery. Global PLC Spare HUB's Insight emphasizes that selecting armored metric probes for hazardous zones protects delicate coaxial pathways from mechanical abrasion and chemical exposure, ensuring uninterrupted condition monitoring data streams.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown Index\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model \u0026amp; Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330104\u003c\/span\u003e\u003c\/strong\u003e - 3300 XL 8 mm Probe, M10 x 1 metric thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length Option (-00-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00 mm unthreaded portion beneath case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Case Length Option (-05-)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm total case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal System Length Option (05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (1.6 feet) total probe cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector \u0026amp; Cable Type (11)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector and FluidLoc cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option (05)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, and IECEx hazardous area certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eComprehensive Technical Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer \/ Brand:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #2b303a;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel \u0026amp; Series:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330104-00-05-05-11-05\u003c\/span\u003e\u003c\/strong\u003e (\u003cspan style=\"color: #0056b3;\"\u003e3300 XL\u003c\/span\u003e 8 mm Series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear Range \u0026amp; Gap:\u003c\/strong\u003e 2 mm linear range (80 mils) spanning 0.25 to 2.3 mm from target; recommended radial vibration gap at -9 Vdc (approx. 1.27 mm \/ 50 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe DC Resistance:\u003c\/strong\u003e R_PROBE is 7.45 ± 0.50 ohms measured from center conductor to outer shield for a 0.5m length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e 0 to 10 kHz with up to 305 meters (1,000 feet) of 3-conductor shielded field wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials:\u003c\/strong\u003e Polyphenylene sulfide (PPS) probe tip, AISI 303\/304 stainless steel case, and FEP-insulated coaxial cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Ratings:\u003c\/strong\u003e Standard probe operation from -52°C to +177°C; extended temperature capability up to +218°C for probe tips and +260°C for cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting and Torque Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M10 x 1 probe case into machine housings up to a maximum thread engagement length of 15 mm.\u003c\/li\u003e\n\u003cli\u003eExercise caution during low-temperature installation; exposing probes to temperatures below -34°C (-30°F) can compromise the Viton O-ring pressure seal.\u003c\/li\u003e\n\u003cli\u003eRoute the armored coaxial cable while respecting mechanical bend limits to prevent internal conductor strain.\u003c\/li\u003e\n\u003cli\u003eEnsure the connector protector is threaded securely over the ClickLoc interface to seal out moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdjust initial mechanical gapping to achieve the recommended -9 Vdc output corresponding to a 1.27 mm air gap.\u003c\/li\u003e\n\u003cli\u003eInspect ClickLoc miniature connectors during scheduled turnarounds to verify that terminal pins remain free of oil and oxidation.\u003c\/li\u003e\n\u003cli\u003ePerform insulation and loop resistance checks on field wiring shields to maintain single-point grounding integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHazardous Area Approvals and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsically Safe (ia):\u003c\/strong\u003e Certified for Class I, Zone 0 (AEx\/Ex ia IIC T5...T1 Ga), Class I\/II\/III Groups A through G when paired with approved zener barriers or galvanic isolators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive (nA, ec):\u003c\/strong\u003e Certified for Class I, Zone 2 (AEx\/Ex nA\/ec IIC T5...T1 Gc) and Class I, Division 2 Groups A, B, C, and D.\u003c\/li\u003e\n\u003cli\u003eDesigned for high humidity tolerance, showing less than 3% change in Average Scale Factor (ASF) under 93% relative humidity conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents and Warranty Commitment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330104-00-05-05-11-05\u003c\/span\u003e\u003c\/strong\u003e proximity probe unit\u003c\/li\u003e\n\u003cli\u003e0.5-meter armored FluidLoc cable with miniature ClickLoc connector and protector\u003c\/li\u003e\n\u003cli\u003eComprehensive 12-month factory warranty backed by Global PLC Spare HUB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGlobal Logistics and Delivery Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShielded inside robust antistatic packaging designed to prevent electrostatic and mechanical transit damage.\u003c\/li\u003e\n\u003cli\u003eExpedited global dispatch managed through premier international couriers including \u003cstrong\u003eFedEx, UPS, and DHL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eGuaranteed processing, inspection, and dispatch turnaround within \u003cstrong\u003e24 to 48 hours\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTarget Industrial Equipment, Applications, and Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Equipment:\u003c\/strong\u003e Heavy industrial steam turbines, centrifugal compressors, large pumps, and gas expanders operating in hazardous explosive atmospheres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplications:\u003c\/strong\u003e Continuous shaft radial vibration monitoring, thrust position measurement, and rotor eccentricity analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e High-frequency eddy current tracking exposes subsynchronous shaft whip and bearing instability long before catastrophic mechanical failure occurs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSelection Guidelines and Model Comparison\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch Thread and Armor Requirements:\u003c\/strong\u003e Choose armored metric M10 x 1 variants when physical cable protection is mandatory in cramped machinery terminal boxes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify System Lengths:\u003c\/strong\u003e Confirm that the 0.5-meter probe lead length correctly interfaces with your designated Proximitor sensor mounting enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComparative Selection Advice:\u003c\/strong\u003e If your installation layout requires a longer unthreaded section, extended case dimensions, or different system length pairings, review the technical specifications for alternative configurations such as the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330104-02-21-10-01-00-bently-nevada-3300-xl-8mm-metric-proximity-probe\"\u003e330104-02-21-10-01-00\u003c\/a\u003e model to ensure a precise mechanical fit for your machine bracket constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific protection does the armor provide on the \u003cspan style=\"color: #0056b3;\"\u003e330104-00-05-05-11-05\u003c\/span\u003e probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The integrated stainless steel armor shields the 75-ohm coaxial cable from physical cuts, hot oil splashes, and abrasive debris on heavy industrial skids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the recommended initial gap voltage set at -9 Vdc?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A -9 Vdc target centers the probe precisely at a 1.27 mm air gap, maximizing the linear measurement range across the 2 mm span.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What field troubleshooting steps should I take if vibration readings fluctuate erratically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Field experience suggests inspecting the ClickLoc connector for moisture ingress, checking cable shield grounding integrity, and verifying that shaft runout is not exceeding linear limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are these probes pressure tested at the factory prior to delivery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Standard probes utilize a Viton O-ring seal to manage differential pressure between the tip and case, but individual pressure testing requires a custom engineering request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do hazardous area certifications affect probe installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: CSA, ATEX, and IECEx approvals dictate that the probe must be wired through approved safety barriers or galvanic isolators when deployed in classified explosive zones.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013948432566,"sku":"330104-00-05-05-11-05","price":216.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada330104_23.jpg?v=1789983817","url":"https:\/\/www.plcsparehub.com\/products\/330104-00-05-05-11-05-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}