{"product_id":"330103-07-12-10-02-00-bently-nevada-precision-proximity-sensor","title":"330103-07-12-10-02-00 Bently Nevada Precision Proximity Sensor","description":"\u003ch3\u003e\u003cstrong\u003e330103-07-12-10-02-00 | 3300 XL 8 mm Probe Engineering Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330103-07-12-10-02-00\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm Proximity Probe\u003c\/strong\u003e designed for non-contact measurement of conductive targets in rotating machinery. It converts changes in probe-to-target distance into an electrical response for a compatible proximity monitoring system.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines an \u003cstrong\u003eM10 × 1 mounting thread\u003c\/strong\u003e, a 70 mm unthreaded section, a 120 mm overall case, and a 1.0 m standard cable. Its 2 mm linear range supports shaft vibration and displacement measurements when the complete transducer system is correctly configured.\u003c\/p\u003e\n\u003cp\u003eEngineers can use this probe in machinery monitoring installations that require reliable shaft measurements, defined mounting geometry, and compatibility with the appropriate Bently Nevada Proximitor Sensor.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Identification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003e3300 XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003e8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete part number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330103-07-12-10-02-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting thread\u003c\/td\u003e\n\u003ctd\u003eM10 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable configuration\u003c\/td\u003e\n\u003ctd\u003e1.0 m standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003e00 — Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew and original, factory packing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e12 months, subject to confirmed sales terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse this configuration tree to verify the complete part number before purchasing a replacement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e3300 XL 8 mm proximity probe\u003c\/li\u003e\n\u003cli\u003eM10 × 1 thread\u003c\/li\u003e\n\u003cli\u003eWithout armor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-07\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUnthreaded length: 70 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-12\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eOverall case length: 120 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eTotal probe cable length: 1.0 m (3.3 ft)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMiniature coaxial ClickLoc connector\u003c\/li\u003e\n\u003cli\u003eStandard cable configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAgency approval option not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection checkpoint:\u003c\/strong\u003e Confirm the mounting thread, case length, cable length, connector, and approval requirements. A matching base model does not guarantee that every configuration will suit the installed system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Performance Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-07-12-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact proximity measurement using eddy-current technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread size\u003c\/td\u003e\n\u003ctd\u003eM10 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal probe cable length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe tip material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe case material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal probe resistance\u003c\/td\u003e\n\u003ctd\u003e7.59 ± 0.50 Ω, center conductor to outer conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear measurement range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified linear interval\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.25–2.3 mm (10–90 mils) from the target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate output interval\u003c\/td\u003e\n\u003ctd\u003e−1 to −17 VDC over the specified linear interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended radial vibration gap\u003c\/td\u003e\n\u003ctd\u003e−9 VDC, approximately 1.27 mm (50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum thread engagement\u003c\/td\u003e\n\u003ctd\u003e15 mm for M10 × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard operating temperature\u003c\/td\u003e\n\u003ctd\u003e−52°C to +177°C (−62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard storage temperature\u003c\/td\u003e\n\u003ctd\u003e−52°C to +177°C (−62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended-temperature probe tip\u003c\/td\u003e\n\u003ctd\u003eUp to +218°C, for the specified extended-temperature probe version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended-temperature cable and connector\u003c\/td\u003e\n\u003ctd\u003eUp to +260°C, for the specified extended-temperature probe version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity performance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in average scale factor after the specified 93% RH test for up to 56 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField wiring range\u003c\/td\u003e\n\u003ctd\u003e0.2–1.5 mm² (16–24 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended field cable\u003c\/td\u003e\n\u003ctd\u003eThree-conductor shielded triad cable with tinned field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum field wiring length\u003c\/td\u003e\n\u003ctd\u003e305 m (1,000 ft) between the compatible Proximitor Sensor and monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approval option\u003c\/td\u003e\n\u003ctd\u003e00 — Not required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical note:\u003c\/strong\u003e The extended-temperature values apply to the specified extended-temperature probe version. Do not assume this standard-cable configuration supports those limits without verifying its exact construction.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMeasurement Characteristics and Engineering Interpretation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear range:\u003c\/strong\u003e The specified 2 mm range supports displacement measurements within the probe's defined operating interval.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap adjustment:\u003c\/strong\u003e The recommended radial vibration gap is approximately 1.27 mm, corresponding to −9 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal interpretation:\u003c\/strong\u003e The supplied voltage interval describes the specified linear region. Verify actual calibration against the complete transducer system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScale factor:\u003c\/strong\u003e Use the manufacturer's applicable calibration data for the exact probe and Proximitor combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement resolution:\u003c\/strong\u003e The supplied specifications do not state a standalone resolution value. Resolution depends on the complete signal chain and monitoring electronics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency response:\u003c\/strong\u003e Confirm the applicable manufacturer's response data before evaluating high-frequency vibration requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProbe output depends on target material, geometry, gap, and the compatible transducer electronics. Use the specified target material and calibration method when comparing measurements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Map | Equipment and Monitoring Objectives\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment category\u003c\/th\u003e\n\u003cth\u003eTypical monitoring objective\u003c\/th\u003e\n\u003cth\u003eEngineering checks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentrifugal compressors\u003c\/td\u003e\n\u003ctd\u003eRelative shaft vibration and displacement monitoring\u003c\/td\u003e\n\u003ctd\u003eConfirm shaft material, mounting reach, and transducer compatibility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteam turbines\u003c\/td\u003e\n\u003ctd\u003eMonitor shaft vibration through a compatible machinery protection channel\u003c\/td\u003e\n\u003ctd\u003eVerify the installed probe family and monitor configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas turbines\u003c\/td\u003e\n\u003ctd\u003eMeasure shaft movement in a configured proximity monitoring system\u003c\/td\u003e\n\u003ctd\u003eCheck operating temperature and installation requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial pumps\u003c\/td\u003e\n\u003ctd\u003eSupport non-contact shaft monitoring where the machine design requires it\u003c\/td\u003e\n\u003ctd\u003eVerify target geometry and available mounting clearance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotating equipment test stands\u003c\/td\u003e\n\u003ctd\u003eMeasure shaft movement during controlled operating tests\u003c\/td\u003e\n\u003ctd\u003eConfirm calibration, cable routing, and acquisition settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese examples describe potential applications rather than universal compatibility. Confirm the machine manufacturer's requirements before selecting a probe for a specific installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Sequence\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the mechanical interface.\u003c\/strong\u003e Confirm the M10 × 1 thread and 120 mm case length against the installation drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the mounting depth.\u003c\/strong\u003e Observe the 15 mm maximum thread engagement and verify the available probe clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the shaft target.\u003c\/strong\u003e Check surface condition, target material, runout, and the required sensing location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the probe gap.\u003c\/strong\u003e Use the recommended −9 VDC reference for radial vibration when the specified transducer chain supports this procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the cable.\u003c\/strong\u003e Avoid crushing, abrasion, sharp bends, and routing beside strong interference sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect the system.\u003c\/strong\u003e Verify the ClickLoc connector and compatible extension cable, Proximitor Sensor, and monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecord commissioning data.\u003c\/strong\u003e Document static gap voltage, channel status, and machine operating conditions for future comparison.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the manufacturer's installation drawing and the machine-specific safety procedure. Avoid excessive mechanical force during installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMaintenance Diagnostics | Practical Fault Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003ePotential cause\u003c\/th\u003e\n\u003cth\u003eRecommended investigation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGap voltage differs from the original baseline\u003c\/td\u003e\n\u003ctd\u003eChanged probe position, target condition, or transducer configuration\u003c\/td\u003e\n\u003ctd\u003eVerify the mounting depth, target clearance, and calibration records.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable readings after cable work\u003c\/td\u003e\n\u003ctd\u003eLoose connector, damaged cable, or wiring interference\u003c\/td\u003e\n\u003ctd\u003eInspect the connector, cable condition, and routing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbnormal vibration after maintenance\u003c\/td\u003e\n\u003ctd\u003eProbe movement, altered clearance, or a genuine machine condition change\u003c\/td\u003e\n\u003ctd\u003eCheck the measurement chain and compare independent machine data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected channel alarms\u003c\/td\u003e\n\u003ctd\u003eIncorrect system configuration, wiring faults, or out-of-range measurement\u003c\/td\u003e\n\u003ctd\u003eVerify the probe, extension cable, Proximitor Sensor, and monitor settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings change after temperature exposure\u003c\/td\u003e\n\u003ctd\u003eEnvironmental conditions outside the installed version's limits\u003c\/td\u003e\n\u003ctd\u003eVerify actual temperature and the precise probe and cable ratings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A compressor channel shows a different gap voltage after a bearing inspection. The engineer should first verify probe position and cable connections. Next, compare the static reading with the commissioning record. Finally, correlate the vibration trend with machine speed and load. This sequence helps separate installation errors from actual operating changes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Limits and Pressure Sealing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe probe uses a PPS tip and a stainless steel case.\u003c\/li\u003e\n\u003cli\u003eA Viton O-ring seals differential pressure between the probe tip and case.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer does not pressure-test probes before shipment.\u003c\/li\u003e\n\u003cli\u003eSustained exposure below −34°C (−30°F) may cause premature failure of the pressure seal.\u003c\/li\u003e\n\u003cli\u003eThe specified humidity test produced less than a 3% change in average scale factor under its stated conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRequest a dedicated pressure-seal test when the application requires one. Confirm chemical compatibility, pressure conditions, and temperature limits before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCertification and Hazardous-Area Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied part number ends in \u003cstrong\u003e-00\u003c\/strong\u003e, which identifies an approval option that is not required for this ordered configuration. However, the 3300 XL probe family supports different installation approval arrangements under specified conditions.\u003c\/p\u003e\n\u003cp\u003eThe supplied documentation describes intrinsically safe installations using specified Zener barriers or galvanic isolators. It also describes nonincendive installations using the applicable installation drawing.\u003c\/p\u003e\n\u003cp\u003eDo not treat family-level approval information as proof that this exact ordering code is approved for every hazardous area. Verify the equipment marking, system drawing, barrier selection, and site classification before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Review\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFor replacement planning, the key selection variables are the probe's physical reach, cable length, connector option, and calibrated measurement range. These variables determine whether the replacement matches the installed machinery monitoring system.\u003c\/p\u003e\n\u003cp\u003eConsider a compressor where the existing probe uses a 70 mm unthreaded section and a 120 mm case. A replacement with a different case length may change the mounting position or prevent the probe from reaching its specified sensing location.\u003c\/p\u003e\n\u003cp\u003eAnother common maintenance issue occurs when technicians replace a probe but retain an unverified extension cable or Proximitor Sensor. The assembly may connect mechanically while producing an incorrect measurement response. Confirm the complete transducer chain before returning the channel to service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering recommendation:\u003c\/strong\u003e Treat the complete ordering code as the primary replacement reference. Validate the mounting dimensions, electrical configuration, calibration data, and environmental requirements before approving substitution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Comparison and Selection Recommendation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the linked alternative below when comparing mounting dimensions and cable configuration. Confirm its full specification before approving it as a replacement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection criterion\u003c\/th\u003e\n\u003cth\u003eCurrent model\u003c\/th\u003e\n\u003cth\u003eAlternative model\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e330103-07-12-10-02-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-00-06-05-12-05-proximity-transducer-probe-bently-nevada-3300-xl-m10\"\u003e\u003cstrong\u003e330103-00-06-05-12-05\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003ctd\u003e3300 XL M10 proximity probe; verify the exact ordering configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded length\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003ctd\u003eConfirm against the alternative's ordering documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003ctd\u003eConfirm against the alternative's ordering documentation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003ctd\u003eVerify the cable length and complete transducer configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector option\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc, standard cable\u003c\/td\u003e\n\u003ctd\u003eVerify the connector and cable options.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval option\u003c\/td\u003e\n\u003ctd\u003e00 — Not required\u003c\/td\u003e\n\u003ctd\u003e05 — Verify the applicable approvals and installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection priority\u003c\/td\u003e\n\u003ctd\u003eMatch the specified 70 mm and 120 mm mechanical configuration\u003c\/td\u003e\n\u003ctd\u003eConfirm all dimensions, cable options, and approval requirements before substitution.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical recommendation:\u003c\/strong\u003e Select the current model when the installed machine requires its 70 mm unthreaded section, 120 mm case, and 1.0 m standard cable. Consider the alternative only after confirming the complete dimensions, connector configuration, and approval requirements. Do not assume direct interchangeability from the shared 330103 prefix.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Shipping, and Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada 3300 XL 8 mm Proximity Probe, part number 330103-07-12-10-02-00.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e New and original factory packing, subject to order confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months, subject to confirmed seller terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm stock, shipping destination, lead time, and the complete configuration before purchase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Check whether the installed system requires a separate extension cable or other transducer components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Why should engineers check shaft material before selecting a proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEddy-current probe response depends on target material and geometry. A change in shaft material or target dimensions can affect measurement behavior. Confirm the target specifications and calibration requirements before replacing the sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What records help engineers evaluate long-term probe performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eKeep the original part number, installation dimensions, gap voltage, calibration data, and machine operating conditions. Consistent records help engineers identify gradual measurement changes and compare results across maintenance periods.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. How should a team assess a replacement for a probe installed in a restricted space?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the available insertion depth and clearance before ordering. Compare the unthreaded length, case length, cable exit, and connector access against the installation drawing. Confirm that maintenance staff can remove the probe safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Does the stated humidity performance guarantee identical readings in every humid environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The specification describes a defined humidity test with stated conditions and duration. Actual performance depends on the complete installation, temperature, contamination, and environmental exposure. Follow the manufacturer's operating limits and maintenance guidance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. What should buyers request when an application requires documented pressure integrity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRequest confirmation of the pressure-seal requirements and whether a dedicated test is available for the exact configuration. The supplied information states that probes are not pressure-tested before shipment. Confirm the test scope and acceptance criteria before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote from Global PLC Spare HUB\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e for pricing, availability, and configuration assistance for the \u003cstrong\u003e330103-07-12-10-02-00 Bently Nevada 3300 XL 8 mm Proximity Probe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eInclude the complete part number, existing Proximitor Sensor model, cable arrangement, mounting dimensions, and installation requirements. These details help verify the correct configuration before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013948268726,"sku":"330103-07-12-10-02-00","price":246.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_1_e1e66f3b-05c4-4158-8554-5107a441962a.jpg?v=1792466282","url":"https:\/\/www.plcsparehub.com\/products\/330103-07-12-10-02-00-bently-nevada-precision-proximity-sensor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}