{"product_id":"330103-03-06-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe","title":"330103-03-06-05-02-00 Bently Nevada 3300 XL 8mm Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Engineering Brief\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330103-03-06-05-02-00\u003c\/span\u003e\u003c\/strong\u003e is a precision eddy-current proximity transducer belonging to the industrial-standard \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 XL 8 mm\u003c\/span\u003e\u003c\/strong\u003e series.\u003c\/p\u003e\n\u003cp\u003eEngineers deploy this non-contacting sensor to measure static gaps and dynamic displacement profiles against fluid-film bearings safely.\u003c\/p\u003e\n\u003cp\u003eThe M10 x 1 threaded physical body translates micro-inch movements into linear DC voltage steps reliably.\u003c\/p\u003e\n\u003cp\u003eIt offers robust structural sealing alongside high-temperature resistance to deliver deterministic, low-noise vibration data within hostile industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e ── Core Proximity Probe Type\n\u003cul\u003e\n\u003cli\u003e↳ Series Type: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 XL 8 mm\u003c\/span\u003e\u003c\/strong\u003e Standard Transducer\u003c\/li\u003e\n\u003cli\u003e↳ Thread Profile: M10 x 1 metric thread\u003c\/li\u003e\n\u003cli\u003e↳ Armor Configuration: Unarmored standard coaxial cable design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e03\u003c\/strong\u003e ── Unthreaded Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 30 mm unthreaded sleeve area\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e06\u003c\/strong\u003e ── Overall Case Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 60 mm total metallic housing length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e ── Total Length Option\n\u003cul\u003e\n\u003cli\u003e↳ Dimension: 0.5 meter (1.6 feet) physical integration length\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e ── Connector \u0026amp; Cable-Type Option\n\u003cul\u003e\n\u003cli\u003e↳ Variant: Miniature coaxial ClickLoc connector with standard electrical cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e ── Agency Approval Option\n\u003cul\u003e\n\u003cli\u003e↳ Status: Base variant, no localized hazardous zone certification tags required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Architecture \u0026amp; Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e330103-03-06-05-02-00\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003e3300 XL 8 mm\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eComponent Type: Non-Contact Eddy Current Proximity Transducer\u003c\/li\u003e\n\u003cli\u003eMeasurement Linear Range: 2 mm (80 mils) total displacement window\u003c\/li\u003e\n\u003cli\u003eOperational Gap Limits: Commences at 0.25 mm (10 mils) up to 2.3 mm (90 mils) from the target face\u003c\/li\u003e\n\u003cli\u003eElectrical Signaling Range: Corresponds linearly from -1 V DC to -17 V DC output levels\u003c\/li\u003e\n\u003cli\u003eRecommended Radial Vibration Gap: Set at -9 V DC bias point (approximately 1.27 mm or 50 mils distance)\u003c\/li\u003e\n\u003cli\u003eNominal Loop DC Resistance: 7.45 ohms ± 0.50 ohms measured between center and outer shield conductors\u003c\/li\u003e\n\u003cli\u003eTip Material Compounding: High-stability Polyphenylene Sulfide polymer\u003c\/li\u003e\n\u003cli\u003eHousing Metallic Composition: AISI 303 or 304 austenitic stainless steel\u003c\/li\u003e\n\u003cli\u003eHigh-Pressure Process Sealing: Integrated Viton O-ring provides a differential pressure barrier between tip and case\u003c\/li\u003e\n\u003cli\u003eMaximum Case Engagement: 15 mm total permissible metric thread mechanical interlock depth\u003c\/li\u003e\n\u003cli\u003eRecommended Installation Torque: 11.2 N·m (100 in·lbf) for standard face mounting operations\u003c\/li\u003e\n\u003cli\u003eMaximum Rated Torque Limit: 33.9 N·m (300 in·lbf) across full threaded section\u003c\/li\u003e\n\u003cli\u003ePhysical Mass Index: Weighs approximately 323 g\/m (11.4 oz)\u003c\/li\u003e\n\u003cli\u003eEnvironmental Protection: Restricts Average Scale Factor shifts below 3% under 93% relative humidity exposure\u003c\/li\u003e\n\u003cli\u003eStandard Temperature Limits: Sustains internal components across a -52 °C to +177 °C operational spectrum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHost Equipment Interoperability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330103-03-06-05-02-00\u003c\/span\u003e\u003c\/strong\u003e functions as the physical front-end capture mechanism, providing direct analog links to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3300 XL Proximitor Sensors (5-meter or 9-meter baseline system tunes)\u003c\/li\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/3500-40m-01-00-4-channel-proximitor-monitor-bently-nevada\"\u003e3500\/40M\u003c\/a\u003e Proximitor Monitor Modules\u003c\/li\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/3500-42m-09-00-bently-nevada-proximitor-seismic-monitor\"\u003e3500\/42M\u003c\/a\u003e Ceramic Bearing Displacement Monitors\u003c\/li\u003e\n\u003cli\u003eBently Nevada \u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/990-991-and-177230-transmitter\"\u003e990 Vibration Transmitters\u003c\/a\u003e for direct PLC\/DCS connection paths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Field Implementations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDynamic radial vibration monitoring of high-speed fluid-film journal bearings.\u003c\/li\u003e\n\u003cli\u003eStatic axial thrust position monitoring on large utility steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eShaft eccentricity measurements and slow-roll machine speed monitoring setups.\u003c\/li\u003e\n\u003cli\u003eStructural case expansion measurements and oil-film clearance tracking in industrial machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eNetwork Diagnostics \u0026amp; Metrology Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDC Loop Impedance Diagnostics: Verification of the 7.45-ohm base resistance quickly flags open coils or cable crimps.\u003c\/li\u003e\n\u003cli\u003eVoltage Gap Verification: Field technicians track the static voltage bias against target surfaces to monitor sensor degradation.\u003c\/li\u003e\n\u003cli\u003eScale Factor Calibration: Tracks thermal shifts to maintain scale accuracy within IEC 68-2-3 standards.\u003c\/li\u003e\n\u003cli\u003eClickLoc Mechanical Verification: Coaxial interfaces verify electrical circuit contact and signal integrity under heavy vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0051ba;\"\u003eBently Nevada 330103-03-06-05-02-00\u003c\/span\u003e\u003c\/strong\u003e provides excellent mechanical reliability for standard metric industrial casings.\u003c\/p\u003e\n\u003cp\u003eThe 30 mm unthreaded sleeve design gives field technicians ample adjustment room inside complex bearing housings.\u003c\/p\u003e\n\u003cp\u003eBy using a compact 0.5-meter cable layout, this module keeps local connections close to the junction box.\u003c\/p\u003e\n\u003cp\u003eThis design minimizes internal electrical noise and eliminates signal distortion caused by excessive field-wire loops effectively.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCross-Model Selection Analysis\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103-03-06-05-02-00\u003c\/strong\u003e (Current Model): Features a standard M10x1 thread path, short 30 mm unthreaded casing, 60 mm case length, and a 0.5-meter standard unarmored cable lead. It is optimized for small internal bearing clearances.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-00-18-10-12-05-bently-nevada-proximity-probe-new\"\u003e\u003cstrong\u003e330103-00-18-10-12-05\u003c\/strong\u003e\u003c\/a\u003e: Features a 0 mm unthreaded sleeve, an extended 1.8-inch case, a 1.0-meter overall length, an armored fluid cable sleeve, and ATEX zone approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Application Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSleeve Selection Rules: Use the 30 mm unthreaded option when mounting through thick external fluid-film casing block walls to prevent thread galling.\u003c\/li\u003e\n\u003cli\u003eCable Protection Rules: If the proximity line is exposed to flying debris or synthetic lubricants outside the machine casing, transition to the armored model link above.\u003c\/li\u003e\n\u003cli\u003eMatched System Tuning: Always verify that the combined length of the probe cable and extension line matches your Proximitor's calibration profile.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLogistical Logistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Packaging: Factory-sealed anti-static shielding box with protective contact caps.\u003c\/li\u003e\n\u003cli\u003eExpress Courier Distribution: Priority global air freight fulfilled via FedEx, UPS, or DHL networks.\u003c\/li\u003e\n\u003cli\u003eProcessing Lead Time: Guaranteed automated packaging and dispatch completed within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003eExtended Coverage: Backed by a comprehensive 12-month industrial replacement warranty covering functional performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvanced Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does an eddy-current probe loop show unstable DC voltage readings right after a new mechanical installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnstable gap voltages usually stem from localized cross-talk caused by incorrect probe-to-probe clearance.\u003c\/p\u003e\n\u003cp\u003eAlternatively, shaft surface irregularities like scratches or magnetized spots can disrupt the eddy-current field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the best way to clean and inspect the ClickLoc coaxial connector during planned plant maintenance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eClean the gold contact pins using a residue-free electronics cleaner spray carefully.\u003c\/p\u003e\n\u003cp\u003eInspect the outer shielding sleeve for physical distortion before latching the connection into place again.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific probe run reliably if submerged continuously in high-pressure synthetic bearing lubricants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the PPS tip and stainless housing withstand standard synthetic oils perfectly.\u003c\/p\u003e\n\u003cp\u003eHowever, you must monitor process temperatures to ensure the built-in Viton O-ring seal stays within its rated range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can field teams quickly test if the transducer coil has suffered internal thermal degradation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDisconnect the sensor and measure the resistance with a calibrated digital multimeter immediately.\u003c\/p\u003e\n\u003cp\u003eA reading outside the 7.45 ohms ± 0.50 ohms specification at room temperature indicates internal thermal breakdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes premature pressure seal failure near the sensor tip when operating in northern outdoor environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExposing the module to temperatures below –34 °C during plant outages can cause the Viton seal material to harden.\u003c\/p\u003e\n\u003cp\u003eThis thermal hardening leads to premature failure under differential process pressures once operations resume.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcurement Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify Case Thread Pitch: Ensure your machine casing matches the metric M10x1 thread profile before completing your procurement paperwork.\u003c\/li\u003e\n\u003cli\u003eCheck Target Material Calibration: Standard probes are calibrated for 4140 steel alloys. Request a custom calibration if your shaft uses alternative steel compositions.\u003c\/li\u003e\n\u003cli\u003eAudit Total Loop Extensions: Double-check your extension cable lengths to ensure the total system impedance matches your Proximitor module's technical specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_48a8dba2-c2d9-4436-8ebd-b7fbeacea3b1.png?v=1782115408\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014041788598,"sku":"330103-03-06-05-02-00","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_11_80ffed7f-8140-4035-94eb-aa8b10979019.jpg?v=1783329733","url":"https:\/\/www.plcsparehub.com\/products\/330103-03-06-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}