{"product_id":"330103-00-15-50-02-00-bently-nevada-probe-3300-xl-8mm-m10-sensor-kit","title":"330103-00-15-50-02-00 Bently Nevada Probe | 3300 XL 8mm M10 Sensor Kit","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e is an industrial-grade eddy current proximity transducer. It belongs to the high-performance \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e3300 XL\u003c\/span\u003e\u003c\/strong\u003e 8 mm series. This metric-threaded sensor measures static and dynamic shaft displacement on critical rotating machinery.\u003c\/p\u003e\n\u003cp\u003eEngineered without external armor, the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e features an integrated 5.0-meter coaxial cable. This design terminates in a standard miniature coaxial ClickLoc connector. It provides reliable, high-accuracy gap measurements for machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur senior instrumentation specialists have analyzed the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e \u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e under continuous-duty industrial scenarios. Unlike standard 1-meter or 2-meter probes that require intermediate extension cables near the machine case, this integrated 5-meter configuration runs directly to your local junction box. Eliminating an intermediate connection point reduces signal attenuation and prevents moisture ingress failures.\u003c\/p\u003e\n\u003cp\u003eWe emphasize that this 5-meter probe is tuned exclusively for use with a 5-meter Proximitor sensor. Using it with a 9-meter driver will cause severe calibration skewing and invalid system scale factors (ASF). The unarmored design makes cable routing simpler in tight conduits, but you should use adequate cable support to prevent jacket wear.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe exact specification profile of the \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e is decoded using the following structured system logic:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Part Number:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103\u003c\/span\u003e\u003c\/strong\u003e (3300 XL 8 mm Probe, M10 x 1 Thread, Unarmored)\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003eUnthreaded Length Suffix:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e-00\u003c\/span\u003e\u003c\/strong\u003e (0 mm minimum unthreaded length; fully threaded body)\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003eOverall Case Length Suffix:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e-15\u003c\/span\u003e\u003c\/strong\u003e (150 mm total case length)\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003eTotal Length Suffix:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e-50\u003c\/span\u003e\u003c\/strong\u003e (5.0 Meters \/ 16.4 Feet total cable length)\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003eConnector Type Suffix:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e-02\u003c\/span\u003e\u003c\/strong\u003e (Miniature coaxial ClickLoc connector, standard cable)\u003c\/li\u003e\n\u003cli\u003e  └── \u003cstrong\u003eAgency Approval Suffix:\u003c\/strong\u003e \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e-00\u003c\/span\u003e\u003c\/strong\u003e (No hazardous area approvals required)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; border-color: #e0e0e0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Brand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Model Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), starting at 0.25 mm (10 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Calibration Gap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc nominal bias [approximately 1.27 mm (50 mils) physical gap]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.73 Ohms ±0.50 Ohms (measured center-to-outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Thread Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm engagement limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-performance Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or AISI 304 Stainless Steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 °C to +177 °C (-62 °F to +350 °F) standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential pressure rated; features integrated Viton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 3% ASF change over 56 days at 93% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e is built for critical machinery monitoring, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine bearing housing relative vibration\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressor radial shaft vibration and rotor thrust position\u003c\/li\u003e\n\u003cli\u003eHigh-pressure boiler feed water pump shaft displacement\u003c\/li\u003e\n\u003cli\u003eGearbox input\/output shaft radial runout diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Comparison \u0026amp; Technical Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTo assist in your engineering review, the table below compares our stocked probe to another common configuration. We recommend confirming your machine casing clearance and cable routing depth before making a selection.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse; border-color: #e0e0e0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"text-align: left;\"\u003eModel Code Selection\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eUnthreaded \/ Case Length\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eTotal System Cable Length\u003c\/th\u003e\n\u003cth style=\"text-align: left;\"\u003eEngineering Recommendation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e (This Model)\u003c\/td\u003e\n\u003ctd\u003e0 mm Unthreaded \/ 150 mm Case\u003c\/td\u003e\n\u003ctd\u003e5.0 Meters (16.4 Feet)\u003c\/td\u003e\n\u003ctd\u003eBest for deep-thread machine casing installations without external structural standoffs. Requires a matching 5-meter Proximitor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-03-06-05-02-00-bently-nevada-3300-xl-8mm-proximity-probe\" target=\"_blank\"\u003e\u003cstrong\u003e330103-03-06-05-02-00\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm Unthreaded \/ 60 mm Case\u003c\/td\u003e\n\u003ctd\u003e0.5 Meters (1.6 Feet)\u003c\/td\u003e\n\u003ctd\u003eBest for shallow casings where partial unthreaded relief is needed. Requires an external extension cable to reach the driver.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics \u0026amp; System Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eA failing sensor link can lead to false trips or missed events. The \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e330103-00-15-50-02-00\u003c\/span\u003e\u003c\/strong\u003e provides precise analog voltage feedback back to your rack. A steady change in DC bias voltage indicates shaft babbitt wear or thrust movement. Dynamic AC voltage components reveal real-time vibration amplitude, orbital paths, and phase reference anomalies.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal Logistics \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Month Quality Warranty:\u003c\/strong\u003e Global PLC Spare HUB provides a full 12-month quality replacement guarantee on this probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Warehousing Dispatch:\u003c\/strong\u003e All orders are securely packed and shipped within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternational Air Express:\u003c\/strong\u003e We ship worldwide using DHL, FedEx, and UPS with tracking provided.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I test the internal coil of a 330103-00-15-50-02-00 probe using a multimeter?\u003c\/strong\u003e\u003cbr\u003eSet your multimeter to measure resistance. Connect one lead to the center pin of the ClickLoc connector and the other to the outer shell. A healthy 5-meter probe must read between 8.23 Ohms and 9.23 Ohms. A reading near zero indicates a short, while an infinite reading indicates an open circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat occurs if I connect this 5-meter probe to a 9-meter Proximitor sensor?\u003c\/strong\u003e\u003cbr\u003eThe Proximitor sensor will fail to calibrate correctly. Because a 9-meter driver expects a combined probe and extension cable length of 9 meters, using a 5-meter probe without an extension cable shifts the impedance curve. This shift degrades calibration linearity and creates inaccurate scale factors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expose the probe tip to sub-zero temperatures safely?\u003c\/strong\u003e\u003cbr\u003eWhile the standard operating range goes down to -52 °C, exposing the assembly to temperatures below -34 °C (-30 °F) can harden the internal Viton O-ring. This hardening may compromise the high-pressure differential seal, leading to process fluid leaks through the case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the correct physical gap during field installation of this M10 probe?\u003c\/strong\u003e\u003cbr\u003eFirst, mount the probe until the tip makes light contact with the target shaft, then back it out approximately 1.27 mm (equivalent to 1.27 turns of the M10x1 thread). Next, power up the Proximitor sensor and monitor the DC output. Adjust the probe position until the voltage reads exactly -9.0 Vdc before tightening the locknuts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the unarmored cable option preferred over the armored version?\u003c\/strong\u003e\u003cbr\u003eUnarmored cables are more flexible and have a smaller overall outer diameter. This makes them much easier to route through tight, complex conduit bends. However, they should only be used where the routing path provides adequate physical protection from mechanical impacts.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_48a8dba2-c2d9-4436-8ebd-b7fbeacea3b1.png?v=1782115408\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014034776246,"sku":"330103-00-15-50-02-00","price":214.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_10.jpg?v=1784189950","url":"https:\/\/www.plcsparehub.com\/products\/330103-00-15-50-02-00-bently-nevada-probe-3300-xl-8mm-m10-sensor-kit","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}