{"product_id":"330103-00-05-90-02-05-bently-nevada-3300-xl-8-mm-metric-proximity-probe","title":"330103-00-05-90-02-05 Bently Nevada 3300 XL 8 mm Metric Proximity Probe","description":"\u003ch3\u003e\u003cb\u003e1. Product Identification | 3300 XL 8 mm Series\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eBently Nevada 330103-00-05-90-02-05\u003c\/b\u003e is a metric \u003cb\u003e3300 XL 8 mm Proximity Probe\u003c\/b\u003e designed for non-contact displacement measurement in rotating machinery monitoring systems. It detects the position of a conductive target, typically a machine shaft, and works with a compatible 3300 XL Proximitor Sensor and monitoring instrument.\u003c\/p\u003e\n\u003cp\u003eThis configuration features an M10 x 1 threaded case, a 50 mm overall case length, a 9.0 m standard cable, and a miniature coaxial ClickLoc connector. Its PPS probe tip and stainless-steel case support industrial monitoring applications where stable mechanical installation and reliable signal transmission are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e2. Configuration Breakdown | Decode the Full Part Number\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eComplete model:\u003c\/b\u003e 330103-00-05-90-02-05\u003c\/p\u003e\n\u003cp\u003eFollow the configuration tree below to identify the supplied probe arrangement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e330103\u003c\/b\u003e — 3300 XL 8 mm proximity probe, M10 x 1 thread, without armor\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e00\u003c\/b\u003e — Unthreaded length option; minimum unthreaded length is 0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e05\u003c\/b\u003e — Overall case length: 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e90\u003c\/b\u003e — Total probe cable length: 9.0 m (29.5 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e02\u003c\/b\u003e — Miniature coaxial ClickLoc connector with standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e05\u003c\/b\u003e — CSA, ATEX, and IECEx approval option, subject to the applicable certification and installation requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eBefore ordering:\u003c\/b\u003e Confirm the complete suffix against the equipment documentation and the applicable manufacturer configuration drawing. Verify that the connector, cable length, thread, and approval requirements match the installed system.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e3. Engineering Data | Key Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e330103-00-05-90-02-05\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe type\u003c\/td\u003e\n\u003ctd\u003eMetric, non-contact displacement probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase thread\u003c\/td\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eWithout armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall case length\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal cable length\u003c\/td\u003e\n\u003ctd\u003e9.0 m (29.5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable type\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe tip\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal probe DC resistance\u003c\/td\u003e\n\u003ctd\u003e9.87 ± 0.50 Ω for the 9.0 m probe configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal linear range\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended radial vibration gap\u003c\/td\u003e\n\u003ctd\u003e-9 VDC, approximately 1.27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval option\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx; verify exact certification for the installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003e4. Measurement Characteristics | Gap and Linear Range\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe probe measures shaft displacement through an electromagnetic sensing arrangement. The output depends on the probe, extension cable, compatible Proximitor Sensor, target material, and installation geometry.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement item\u003c\/th\u003e\n\u003cth\u003eEngineering reference\u003c\/th\u003e\n\u003cth\u003ePractical implication\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal linear range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003ctd\u003eKeep normal measurement within the specified linear region.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified target gap range\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.25–2.3 mm (10–90 mils)\u003c\/td\u003e\n\u003ctd\u003eUse the manufacturer’s calibration and system setup instructions to establish the actual operating gap.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate output range\u003c\/td\u003e\n\u003ctd\u003e-1 to -17 VDC across the stated range\u003c\/td\u003e\n\u003ctd\u003eCheck the gap voltage and signal response during commissioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended radial vibration gap\u003c\/td\u003e\n\u003ctd\u003e-9 VDC, approximately 1.27 mm (50 mils)\u003c\/td\u003e\n\u003ctd\u003eProvides a practical reference point for radial shaft vibration monitoring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eCommissioning note:\u003c\/b\u003e Do not set the probe gap by mechanical distance alone. Verify the actual DC gap voltage with the compatible Proximitor Sensor and follow the system-specific installation procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e5. Mechanical and Environmental Limits\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eInstallation consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum thread engagement\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003ctd\u003eCheck mounting-hole depth and thread engagement before installation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard operating and storage temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F)\u003c\/td\u003e\n\u003ctd\u003eConfirm the temperature at the probe tip, case, cable, and connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtended-temperature probe reference\u003c\/td\u003e\n\u003ctd\u003eProbe tip: -52°C to +218°C; cable and connector: -51°C to +260°C\u003c\/td\u003e\n\u003ctd\u003eThese extended limits apply to the appropriate extended-temperature configuration; do not assume they apply to this standard-cable model.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity performance\u003c\/td\u003e\n\u003ctd\u003eLess than 3% change in Average Scale Factor under the stated 93% humidity test for up to 56 days\u003c\/td\u003e\n\u003ctd\u003eFollow the applicable installation and environmental requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure seal\u003c\/td\u003e\n\u003ctd\u003eViton® O-ring\u003c\/td\u003e\n\u003ctd\u003eThe probe is designed to seal differential pressure between the tip and case, but is not pressure-tested before shipment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-temperature caution\u003c\/td\u003e\n\u003ctd\u003eExposure below -34°C (-30°F) may cause premature pressure-seal failure\u003c\/td\u003e\n\u003ctd\u003eAssess the actual operating environment and seal requirements before use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003ePressure application warning:\u003c\/b\u003e If the installation requires a verified pressure seal, request the manufacturer’s guidance on testing and suitability before commissioning. Do not assume the probe has passed a pressure test.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e6. Cable, Connector and Field Wiring\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProbe assembly:\u003c\/b\u003e This model includes a 9.0 m standard cable and a miniature coaxial ClickLoc connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField wiring conductor size:\u003c\/b\u003e 0.2–1.5 mm² (16–24 AWG), according to the supplied technical data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRecommended wiring:\u003c\/b\u003e Three-conductor shielded triad cable with tinned field wiring, as specified for the applicable system arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum field-wiring length:\u003c\/b\u003e 305 m (1,000 ft) between the 3300 XL Proximitor Sensor and the monitor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-frequency performance:\u003c\/b\u003e Longer field wiring can cause signal roll-off. Review the manufacturer’s frequency-response data when designing long cable runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eImportant distinction:\u003c\/b\u003e The 9.0 m length is the probe assembly’s specified total cable length. The 305 m figure refers to the separate field-wiring distance between the Proximitor Sensor and monitor. These are different cable segments and should not be treated as interchangeable limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e7. Hazardous-Area Installation and Approvals\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specified suffix includes a CSA, ATEX, and IECEx approval option. The supplied technical information also describes installation arrangements for intrinsically safe and nonincendive circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eIntrinsically safe installation:\u003c\/b\u003e The referenced documentation describes use with suitable Zener barriers or galvanic isolators, following drawing 141092 and the applicable system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNonincendive installation:\u003c\/b\u003e The referenced documentation identifies circuit connections following drawing 140979.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eArea classification:\u003c\/b\u003e The listed classifications include specified Class I, Zone 0 and Zone 2, and Division 2 applications, depending on the protection method and approved configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHazardous-area suitability depends on the complete installed circuit, associated apparatus, wiring method, temperature class, gas or dust group, and local regulations. Confirm the exact markings and certificates for the supplied item before installation. Do not rely on the suffix alone to establish system-level compliance.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e8. Applications | Where This Probe Fits\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eSteam and gas turbines:\u003c\/b\u003e Shaft vibration and relative displacement monitoring when the installed monitoring system supports the probe configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCentrifugal compressors:\u003c\/b\u003e Non-contact shaft movement measurement for machinery protection and condition monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePumps and industrial drives:\u003c\/b\u003e Radial shaft vibration monitoring on compatible machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGearboxes and rotating equipment:\u003c\/b\u003e Shaft position and dynamic displacement measurement where an appropriate conductive target and mounting arrangement are available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePlant machinery protection systems:\u003c\/b\u003e Integration with compatible Bently Nevada 3300 XL Proximitor Sensors and monitoring channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eCompatibility check:\u003c\/b\u003e Verify the required probe system length, Proximitor Sensor model, monitor input, target material, mounting thread, and hazardous-area design. A probe should not be selected by physical appearance or thread size alone.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e9. Diagnostic Guidance | Common Field Checks\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved condition\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo signal or a channel fault\u003c\/td\u003e\n\u003ctd\u003eLoose connector, open circuit, wiring fault, or incompatible system component\u003c\/td\u003e\n\u003ctd\u003eInspect the connector and wiring. Verify the probe, cable, Proximitor Sensor, and monitor configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnstable gap voltage\u003c\/td\u003e\n\u003ctd\u003eLoose mounting, damaged cable, poor connection, or an unstable shaft target\u003c\/td\u003e\n\u003ctd\u003eCheck mechanical security, cable routing, connector seating, and shaft condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected vibration amplitude\u003c\/td\u003e\n\u003ctd\u003eIncorrect gap setting, target runout, electrical interference, or a genuine machine condition\u003c\/td\u003e\n\u003ctd\u003eVerify the DC gap voltage and compare the signal with independent measurements and machine operating conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReduced high-frequency response\u003c\/td\u003e\n\u003ctd\u003eExcessive field wiring length or system configuration outside the recommended arrangement\u003c\/td\u003e\n\u003ctd\u003eReview the manufacturer's frequency-response data and confirm the complete probe-system configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent readings at low temperature\u003c\/td\u003e\n\u003ctd\u003ePossible pressure-seal degradation or cable\/connector issues\u003c\/td\u003e\n\u003ctd\u003eReview environmental exposure and inspect the assembly using the approved maintenance procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous-area compliance concern\u003c\/td\u003e\n\u003ctd\u003eIncorrect barrier, isolator, wiring method, or certification match\u003c\/td\u003e\n\u003ctd\u003eCompare the installed circuit with the approved control drawing and the equipment certification documents.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cb\u003eDiagnostic limitation:\u003c\/b\u003e The probe is a sensing component, not a standalone diagnostic monitor. Fault alarms, vibration trends, alert limits, and machine-protection decisions depend on the connected Proximitor Sensor, monitor channel, configuration, and monitoring software.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e10. Global PLC Spare HUB's Insight | Selection and Maintenance Notes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFor machinery monitoring, the probe assembly and its associated electronics must be treated as one measurement chain. A correct thread and cable length do not guarantee electrical compatibility or measurement accuracy.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFor replacement planning:\u003c\/b\u003e Match the complete part number, including the case-length, cable-length, connector, and approval suffixes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor retrofit projects:\u003c\/b\u003e Confirm the installed Proximitor Sensor and monitor requirements before substituting a different probe or cable arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor commissioning:\u003c\/b\u003e Check the gap voltage, mechanical mounting, connector engagement, signal stability, and monitor channel configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor harsh environments:\u003c\/b\u003e Assess temperature exposure, cable routing, pressure-seal requirements, and hazardous-area certification as separate engineering checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor maintenance teams:\u003c\/b\u003e Record the installed model, measured gap voltage, machine operating state, and baseline vibration data. This helps distinguish installation problems from actual machinery changes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003e11. Five Professional FAQs | Selection and Troubleshooting\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ1. Can the 330103-00-05-90-02-05 replace another 3300 XL 8 mm probe with the same M10 x 1 thread?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNot automatically. Confirm the complete part number, case length, cable length, connector type, approval requirements, and compatibility with the existing Proximitor Sensor. A matching thread does not establish electrical or mechanical interchangeability.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ2. What should an engineer verify if the replacement probe produces a different DC gap voltage?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFirst confirm the measurement method and the specified gap-setting procedure. Then check the mounting position, target material, connector seating, cable condition, and Proximitor Sensor compatibility. Compare results with the manufacturer's system specifications before concluding that the probe is defective.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ3. Is the 9.0 m cable suitable for every installation requiring a 3300 XL 8 mm probe?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The cable length must match the compatible Proximitor Sensor and the complete measurement-chain requirements. Check the existing system documentation before ordering. Also distinguish the probe assembly's 9.0 m cable from the separate field wiring between the Proximitor Sensor and monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ4. Can this standard-cable version be installed where temperatures reach the extended-temperature limits?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eDo not assume so. The supplied specifications list separate limits for the standard probe and an extended-temperature configuration. Verify the exact part configuration and temperature ratings of the probe tip, cable, and connector against the actual operating conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ5. What information should be provided when requesting a replacement quote?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full part number, installed Proximitor Sensor model, monitor or rack type, required cable length, mounting-thread details, operating temperature, and hazardous-area requirements. If possible, include a photo of the nameplate and the existing installation. This reduces the risk of ordering a probe with the wrong connector, cable, or approval configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003e12. Ordering, Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eProduct:\u003c\/b\u003e Bently Nevada 330103-00-05-90-02-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSeries:\u003c\/b\u003e 3300 XL 8 mm Proximity Probes, Metric\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch target:\u003c\/b\u003e 24–48 hours after order confirmation, subject to stock availability and payment clearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBefore dispatch:\u003c\/b\u003e Confirm the model suffix, product condition, packaging, and any documentation required for the installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eRequest a quotation\u003c\/b\u003e for the Bently Nevada 330103-00-05-90-02-05. Include your quantity, destination country, and any compatibility or certification requirements so the order can be reviewed against your application.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013838299318,"sku":"330103-00-05-90-02-05","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_1_9b22b8b7-0f6f-4928-a718-38284a6d3e2a.jpg?v=1792043652","url":"https:\/\/www.plcsparehub.com\/products\/330103-00-05-90-02-05-bently-nevada-3300-xl-8-mm-metric-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}