{"product_id":"330103-00-04-50-02-00-bently-nevada-eddy-current-transducer","title":"330103-00-04-50-02-00 Bently Nevada Eddy Current Transducer","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330103-00-04-50-02-00 Bently Nevada\u003c\/strong\u003e\u003c\/span\u003e 3300 XL 8 mm Proximity Probe is a high-precision eddy current displacement transducer built for continuous shaft vibration and position surveillance on critical rotating machinery. Featuring an M10x1 metric thread with an unthreaded length of 0 mm and a 40 mm overall case length, this sensor incorporates a 5.0-meter integral cable fitted with a ClickLoc coaxial connector. It delivers strict linear voltage output when paired with a matching 5-meter Proximitor Sensor for non-contact shaft measurement in hazardous, high-temperature industrial environments.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Architecture Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada 3300 XL 8 mm Probe Series\u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Part Code [330103]:\u003c\/strong\u003e Metric M10 x 1 Threaded Case, Standard 8 mm Tip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Length Option [00]:\u003c\/strong\u003e 0 mm (Fully Threaded Case Body)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Case Length Option [04]:\u003c\/strong\u003e 40 mm Case Length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Length Option [50]:\u003c\/strong\u003e 5.0 Meters (16.4 Feet) Integral Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector \u0026amp; Cable Option [02]:\u003c\/strong\u003e Miniature Coaxial ClickLoc Connector, Standard Cable Construction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval Option [00]:\u003c\/strong\u003e Standard Non-Approved Commercial Variant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications \u0026amp; Operating Boundaries\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eEngineering Parameter\u003c\/th\u003e\n\u003cth\u003eField Specification Detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Part Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330103-00-04-50-02-00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 8 mm Transducer System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils), spanning 0.25 mm to 2.3 mm gap (-1 to -17 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc [approximately 1.27 mm (50 mils) physical standoff]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDC Loop Resistance (RPROBE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.73 ± 0.50 Ω (Center Conductor to Outer Shielding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Threading \u0026amp; Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetric M10x1 Thread (Maximum thread engagement length: 15 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel Housing Body\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS) Molded Tip Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Sealing Boundary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton O-Ring differential seal between probe tip and metal case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard rating: -52°C to +177°C (-62°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3% change in Average Scale Factor (ASF) per IEC 68-2-3 (56 days @ 93% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatible Hardware \u0026amp; Operational Deployments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Electronics \u0026amp; Cable Interconnects:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3300 XL 5-Meter Proximitor Sensors\u003c\/strong\u003e\u003c\/span\u003e (System length MUST match total cable length).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e3500\/40M \u0026amp; 3500\/42M Machinery Protection Monitors\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e3-conductor shielded triad field extension cabling (up to 305 meters \/ 1,000 feet).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Machinery \u0026amp; Industrial Systems:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRadial journal bearing dynamic vibration measurement on boiler feed pumps, steam turbines, and gearboxes.\u003c\/li\u003e\n\u003cli\u003eAxial shaft displacement (thrust position monitoring) on high-speed centrifugal gas compressors.\u003c\/li\u003e\n\u003cli\u003eKeyphasor phase reference signal generation on electric motors and generator shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostic \u0026amp; Predictive Monitoring Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330103-00-04-50-02-00 Bently Nevada\u003c\/strong\u003e\u003c\/span\u003e eddy current transducer provides continuous, real-time gap voltage outputs that reflect physical shaft clearance relative to the probe tip. When connected to a 3300 XL Proximitor, signal attenuation or unexpected baseline shift directly points to physical mechanical degradation. An open DC loop resistance (\u0026gt;9.23 Ω) reveals cable damage, while a voltage clamp near zero indicates conductor short-circuiting. The system's tight scale factor tolerance (±5% ASF) enables early detection of shaft runout, sub-synchronous oil whirl, and unbalance conditions long before catastrophic mechanical bearing breakdown.\u003c\/p\u003e\n\u003ch3\u003eGlobal PLC Spare HUB's Insight\u003c\/h3\u003e\n\u003cp\u003eDuring an emergency overhaul on a high-pressure pump skid, vibration analysts reported severe baseline signal drift on a newly installed proximity loop. Field testing revealed that a 5-meter probe (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330103-00-04-50-02-00\u003c\/strong\u003e\u003c\/span\u003e) had been mistakenly wired directly into a 9-meter Proximitor Sensor using an extra extension cable, throwing the scale factor out of calibration. Replacing the mismatched Proximitor with a dedicated 5-meter unit restored proper linear scale response (-200 mV\/mil output across the entire 80-mil gap window). Ensuring system length matching across probe, extension cable, and driver electronics remains crucial for valid vibration monitoring.\u003c\/p\u003e\n\u003ch3\u003eWarranty, Logistics \u0026amp; Fast Shipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Supply State:\u003c\/strong\u003e 100% Brand New and Authentic Industrial Stock\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Standard 12-Month Quality Guarantee from dispatch date\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Processing:\u003c\/strong\u003e Rapid order execution, shipping within 24 to 48 hours post-payment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpress Logistics Delivery:\u003c\/strong\u003e Priority global transport via FedEx, UPS, and DHL Express networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Selection \u0026amp; Operational FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is it mandatory to connect a 5-meter probe assembly directly to a 5-meter rated Proximitor Sensor without using extension cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProximitor drivers are factory-tuned to oscillate at specific resonant circuit parameters based on total system length. Connecting a 5-meter probe (\u003cspan style=\"color: #0056b3;\"\u003e\u003cstrong\u003e330103-00-04-50-02-00\u003c\/strong\u003e\u003c\/span\u003e) directly to a 5-meter driver preserves precise impedance matching without needing intermediate extension cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do technicians verify physical mounting depth when installing an unthreaded option 00 variant?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause option 00 features zero unthreaded length, the entire 40 mm stainless casing is threaded. Technicians must adjust thread engagement using external locking nuts while monitoring DC bias voltage with a digital multimeter until reaching the target gap reading (-9.0 Vdc).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat physical failure mode occurs if operating temperatures drop below -34°C (-30°F)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSub-zero exposure below -34°C hardens the internal Viton O-ring pressure seal between the PPS tip and metal casing, leading to elasticity loss and eventual differential pressure leakage under severe fluid seal operating constraints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can engineers prevent cable connector loosening caused by high-frequency machinery vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc coaxial connector incorporates a spring-loaded mechanical lock ring. Technicians must press and twist the outer sleeve until it firmly snaps into position, followed by applying silicon connector protectors or heat-shrink tubing to prevent oil ingress.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat target material properties are required to maintain a calibrated -200 mV\/mil scale factor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard scale factor calibration assumes an AISI 4140 steel shaft target. Installing the probe over stainless steel or specialized alloy target shafts alters magnetic permeability, requiring custom electrical recalibration or scaling corrections inside the monitoring software.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014035005622,"sku":"330103-00-04-50-02-00","price":265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_1_e48acabc-ab84-4b65-9552-17190055e84a.jpg?v=1787731073","url":"https:\/\/www.plcsparehub.com\/products\/330103-00-04-50-02-00-bently-nevada-eddy-current-transducer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}