{"product_id":"330103-00-03-10-01-00-bently-nevada-3300-xl-probe-without-armor","title":"330103-00-03-10-01-00 Bently Nevada 3300 XL Probe Without Armor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e330103-00-03-10-01-00\u003c\/strong\u003e eddy current proximity probe measures dynamic shaft movement.\u003c\/p\u003e\n\u003cp\u003eReliable non-contact sensing provides accurate shaft vibration and axial position feedback for critical industrial machinery.\u003c\/p\u003e\n\u003cp\u003eThis sensor incorporates an M10x1 metric thread pattern constructed from AISI 303\/304 stainless steel.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e : \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL\u003c\/strong\u003e 8 mm Probe with M10 x 1 Thread (Unarmored)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e : Unthreaded Length Option — 0 mm\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e03\u003c\/strong\u003e : Overall Case Length Option — 30 mm\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e : Total Length Option — 1.0 meter (3.3 feet)\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e : Connector \u0026amp; Cable Option — Miniature coaxial ClickLoc with connector protector, standard cable\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e : Agency Approval Option — Not required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem Parameter Group\u003c\/th\u003e\n\u003cth\u003eTechnical Attribute\u003c\/th\u003e\n\u003cth\u003eAttribute Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Architecture\u003c\/td\u003e\n\u003ctd\u003eManufacturer \u0026amp; Series\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL\u003c\/strong\u003e 8 mm System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentity \u0026amp; Architecture\u003c\/td\u003e\n\u003ctd\u003eComplete Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003e330103-00-03-10-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \u0026amp; Materials\u003c\/td\u003e\n\u003ctd\u003eProbe Tip \u0026amp; Case Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS) \/ AISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical \u0026amp; Materials\u003c\/td\u003e\n\u003ctd\u003eCase Thread \u0026amp; Engagement\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 thread pitch \/ 15 mm maximum thread engagement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Characteristics\u003c\/td\u003e\n\u003ctd\u003eLinear Range \u0026amp; Output\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils) linear range \/ -1 Vdc to -17 Vdc scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Characteristics\u003c\/td\u003e\n\u003ctd\u003eProbe Resistance (RPROBE)\u003c\/td\u003e\n\u003ctd\u003e7.59 ± 0.50 Ohms (center conductor to outer conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Characteristics\u003c\/td\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc [approximately 1.27 mm (50 mils)] for radial vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Endurance\u003c\/td\u003e\n\u003ctd\u003eStandard Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F) operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Endurance\u003c\/td\u003e\n\u003ctd\u003eHumidity Endurance Rating\u003c\/td\u003e\n\u003ctd\u003eLess than 3% ASF change under 93% humidity (IEC 68-2-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Approvals\u003c\/td\u003e\n\u003ctd\u003eIntrinsic Safety (ia)\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga; Class I Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Approvals\u003c\/td\u003e\n\u003ctd\u003eNon-Incendive (nA, ec)\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA IIC T5...T1 Gc; Class I Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Selection \u0026amp; Technical Comparison\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eChoosing the correct proximity probe requires evaluating mechanical dimensions and environmental conditions.\u003c\/p\u003e\n\u003cp\u003eCompare the \u003cstrong style=\"color: #0056b3;\"\u003e330103-00-03-10-01-00\u003c\/strong\u003e against the \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/330103-00-19-10-12-00-bently-nevada-3300-xl-8mm-proximity-probe\"\u003e330103-00-19-10-12-00\u003c\/a\u003e variant:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Length Difference:\u003c\/strong\u003e Option 03 (30 mm) provides a compact body for shallow mounting brackets. Option 19 (190 mm) extends deep into thick machine housings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable \u0026amp; Connector Protection:\u003c\/strong\u003e Option 01 uses standard coaxial cable with a ClickLoc connector protector. Option 12 features a FluidLoc cable to prevent oil migration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering Guidance:\u003c\/strong\u003e Select the \u003cstrong style=\"color: #0056b3;\"\u003e330103-00-03-10-01-00\u003c\/strong\u003e for external bracket installations requiring moisture protection. Select the FluidLoc alternative if cabling runs inside oil-filled bearing housings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Torque Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApply 11.2 N·m (100 in·lbf) recommended torque when mounting the probe body into standard brackets.\u003c\/li\u003e\n\u003cli\u003eDo not exceed 22.6 N·m (200 in·lbf) maximum torque when engaging only the first three threads.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum mechanical thread engagement depth of 15 mm for M10x1 threads.\u003c\/li\u003e\n\u003cli\u003eSet the mechanical gap distance to output -9 Vdc using a calibrated digital multimeter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility \u0026amp; Field Wiring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnects directly to \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL\u003c\/strong\u003e 8 mm Proximitor Sensors.\u003c\/li\u003e\n\u003cli\u003eRequires 3-conductor shielded triad cable for extension wiring up to 305 meters (1,000 feet).\u003c\/li\u003e\n\u003cli\u003eSupports field wiring sizes ranging from 0.2 to 1.5 mm\u003csup\u003e2\u003c\/sup\u003e (16 to 24 AWG).\u003c\/li\u003e\n\u003cli\u003eIntegrates seamlessly into 3500 and 1900\/65 machinery protection monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment \u0026amp; Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring shaft radial vibration on high-speed centrifugal gas compressors.\u003c\/li\u003e\n\u003cli\u003eMeasuring axial thrust position on steam turbine generator rotors.\u003c\/li\u003e\n\u003cli\u003eTracking phase reference speed signals on industrial gearboxes using Keyphasor targets.\u003c\/li\u003e\n\u003cli\u003eMeasuring shaft position and eccentricity on heavy boiler feed pumps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors continuous DC bias voltage to verify proper probe tip gap positioning.\u003c\/li\u003e\n\u003cli\u003eDetects physical target loss or broken coaxial cables via supply signal drops.\u003c\/li\u003e\n\u003cli\u003eMaintains Average Scale Factor (ASF) stability across high-humidity operating environments.\u003c\/li\u003e\n\u003cli\u003eViton O-ring seal isolates internal process pressures between probe tip and case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents, Logistics \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLogistics Attribute\u003c\/th\u003e\n\u003cth\u003eService Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Physical Mass\u003c\/td\u003e\n\u003ctd\u003e323 g\/m (11.4 oz) unit cable weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Coverage\u003c\/td\u003e\n\u003ctd\u003e12 Months comprehensive replacement coverage guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispatch Handling\u003c\/td\u003e\n\u003ctd\u003eFast order processing within 24 to 48 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpress Worldwide Shipping\u003c\/td\u003e\n\u003ctd\u003eGlobal door-to-door delivery options via FedEx, UPS, and DHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOur vibration engineers often resolve noisy signal issues on \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e \u003cstrong style=\"color: #0056b3;\"\u003e3300 XL\u003c\/strong\u003e installations.\u003c\/p\u003e\n\u003cp\u003eField technicians frequently overlook installing the ClickLoc connector protector during routine maintenance.\u003c\/p\u003e\n\u003cp\u003eUnprotected coaxial connectors accumulate airborne moisture, causing scale factor shifts over time.\u003c\/p\u003e\n\u003cp\u003eUsing the \u003cstrong style=\"color: #0056b3;\"\u003e330103-00-03-10-01-00\u003c\/strong\u003e with its factory connector protector keeps signal lines completely dry.\u003c\/p\u003e\n\u003cp\u003eProper gap setting at -9 Vdc ensures linear dynamic range performance without signal clipping.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What is the main structural advantage of a 30 mm case length proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The compact 30 mm body fits tight external brackets where machine casing clearance remains limited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Why should technicians install the included ClickLoc connector protector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: The protector seals coaxial junction points against oil mist, moisture, and dust contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: What voltage reading indicates the correct initial gap setting for radial vibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Set the mechanical gap until the proximitor sensor outputs -9 Vdc at center position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: Can sub-zero operating temperatures affect probe pressure sealing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Temperatures below -34°C (-30°F) may cause premature seal degradation on standard Viton O-rings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion: How does case torque impact short-case probe installation reliability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAnswer: Excessive torque distorts probe threads, so limit recommended tightening to 11.2 N·m.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45014034809014,"sku":"330103-00-03-10-01-00","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330103_11_fb51e48e-d29a-4038-b993-7e391dddc300.jpg?v=1786954472","url":"https:\/\/www.plcsparehub.com\/products\/330103-00-03-10-01-00-bently-nevada-3300-xl-probe-without-armor","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}