{"product_id":"330102-00-40-10-01-05-bently-nevada-3300-xl-8-mm-proximity-probe","title":"330102-00-40-10-01-05 Bently Nevada 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003e\u003cstrong\u003eProduct Summary \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1d4ed8; font-weight: bold;\"\u003e330102-00-40-10-01-05\u003c\/span\u003e \u003cspan style=\"color: #1d4ed8; font-weight: bold;\"\u003eBently Nevada\u003c\/span\u003e \u003cspan style=\"color: #1d4ed8; font-weight: bold;\"\u003e3300 XL 8 mm Proximity Probe\u003c\/span\u003e delivers highly accurate shaft vibration and position measurements. Engineering teams rely on this transducer for continuous monitoring of critical rotating machinery.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eEngineering Definition\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e330102\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003eOption 00\u003c\/td\u003e\n\u003ctd\u003e00 inches unthreaded portion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003eOption 40\u003c\/td\u003e\n\u003ctd\u003e4 inches total case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003eOption 10\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (3.3 feet) cable span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector \u0026amp; Cable\u003c\/td\u003e\n\u003ctd\u003eOption 01\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eOption 05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOperational Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils); spans from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e-9 Vdc (approximately 1.27 mm \/ 50 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Resistance\u003c\/td\u003e\n\u003ctd\u003e7.59 ± 0.50 ohms (Center to Outer Conductor at 1.0m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Compatibility\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.5 mm2 (16 to 24 AWG) shielded triad cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +350°F) standard operational limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase \u0026amp; Tip Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303\/304 stainless steel case with PPS probe tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Sealing\u003c\/td\u003e\n\u003ctd\u003eViton O-ring differential pressure seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e323 g\/m (11.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Mechanical Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify mounting hole cleanliness before threading the 3\/8-24 UNF housing.\u003c\/li\u003e\n\u003cli\u003eStrictly limit thread engagement depth to a maximum of 0.563 inches.\u003c\/li\u003e\n\u003cli\u003eMaintain a maximum field wiring run of 305 meters (1,000 feet) to limit high-frequency roll-off.\u003c\/li\u003e\n\u003cli\u003eProtect the Viton O-ring seal by avoiding sustained temperatures below -34°C (-30°F).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Typical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects sub-synchronous vibration, rotor unbalance, and shaft misalignment instantly.\u003c\/li\u003e\n\u003cli\u003eDelivers reliable gap voltage feedback for startup and shutdown transient analysis.\u003c\/li\u003e\n\u003cli\u003eEngineered for heavy-duty deployment in steam turbines, centrifugal compressors, and large pumps.\u003c\/li\u003e\n\u003cli\u003ePerforms exceptionally well in hazardous petrochemical plant environments requiring CSA and ATEX compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eField instrument engineers frequently encounter high-frequency signal attenuation when long triad cables exceed recommended signal limits. Our technical team recommends evaluating frequency response curves whenever field wiring approaches the 305-meter threshold. Ensuring proper shield grounding at the monitor termination side successfully eliminates common-mode electrical noise in high-interference turbine enclosures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompliance, Warranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHazardous Certifications: Class I, Zone 0\/2 and Division 1\/2 ratings via CSA, ATEX, and IECEx frameworks.\u003c\/li\u003e\n\u003cli\u003eQuality Assurance: Backed by a dependable 12-month industrial warranty.\u003c\/li\u003e\n\u003cli\u003eFulfillment Logistics: Rapid 24-48 hour global dispatch via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the \u003cspan style=\"color: #1d4ed8; font-weight: bold;\"\u003e330102-00-40-10-01-05\u003c\/span\u003e include stainless steel armor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The integrated armor protects the coaxial cable from mechanical abrasion, chemical exposure, and heavy foot traffic in congested industrial skids.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I select between different unthreaded length options during plant retrofits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Match the unthreaded length to your mounting bracket thickness. Option 00 provides zero unthreaded casing, making it ideal for direct flush-mount bracket assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What causes premature failure of the probe's pressure seal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Exposing the Viton O-ring to cryogenic temperatures below -34°C causes material hardening and subsequent pressure barrier compromise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use standard unshielded cable for field wiring runs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, engineers must use a 3-conductor shielded triad cable to prevent electromagnetic interference from distorting the proximity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the 7.59 ohm DC resistance specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Measuring this resistance helps maintenance personnel verify probe integrity and cable health during routine loop check troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/330101-104_4dbdd848-d340-4da7-8f4b-5538f195a28f.png?v=1785135121\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013919203510,"sku":"330102-00-40-10-01-05","price":247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/3301025.jpg?v=1789451050","url":"https:\/\/www.plcsparehub.com\/products\/330102-00-40-10-01-05-bently-nevada-3300-xl-8-mm-proximity-probe","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}