{"product_id":"32000-28-05-05-110-03-02-bently-nevada-32000-metric-proximity-probe-housing","title":"32000-28-05-05-110-03-02 Bently Nevada 32000 Metric Proximity Probe Housing","description":"\u003ch3\u003e\u003cstrong\u003eMechanical Protection \u0026amp; External Transducer Access\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e is an externally mounted metric proximity probe housing engineered by Bently Nevada within the rugged \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000\u003c\/strong\u003e\u003c\/span\u003e housing assembly family. Manufactured in the U.S.A., this Type 4X and IP66-rated enclosure enables field technicians to inspect, adjust, or replace internal \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 XL 8 mm\u003c\/strong\u003e\u003c\/span\u003e eddy current probes without disassembling bearing caps or shutting down critical rotating machinery.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePart Number Suffix \u0026amp; Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eConfiguration Parameter\u003c\/th\u003e\n\u003cth\u003eEngineered Specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e32000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Series Architecture\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000\u003c\/strong\u003e\u003c\/span\u003e Metric Proximity Probe Housing Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe Option (With Connector)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e3300 XL 8 mm\u003c\/strong\u003e\u003c\/span\u003e probe with multiple hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe Cable Length Option\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in) coaxial lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e50 mm standoff length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e110 mm insertion depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFittings Option\u003c\/td\u003e\n\u003ctd\u003eTwo plugs, one M20 fitting, and one cable seal grip with grommets for armored probe cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT process connection (mandatory for Standoff Adapter configurations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMaterial Composition \u0026amp; Environmental Resilience\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer \u0026amp; Model:\u003c\/strong\u003e Bently Nevada | \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e (Made in U.S.A.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Body Material:\u003c\/strong\u003e Glass-reinforced Polyphenylene Sulfide (PPS) thermoplastic infused with conductive fibers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallic Hardware \u0026amp; Sleeves:\u003c\/strong\u003e AISI 304 stainless steel internal sleeve and retaining chain; AISI 303 stainless steel outer sleeve and exterior fasteners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Sealing:\u003c\/strong\u003e Neoprene® O-ring seals across cover and thread interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress \u0026amp; Electrostatic Ratings:\u003c\/strong\u003e CSA certified Type 4X; IP66 verified per SC115582-1 (e) 106; CENELEC EN50014 compliant for electrostatic dissipation in hazardous zones\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Impact Strength:\u003c\/strong\u003e BASEEFA certified for dual 4 Joule (3.0 ft·lb) impacts at -39°C (-38°F) and +115°C (239°F); CSA verified for 7 Joule (5.2 ft·lb) impact at ambient temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e -51°C to +105°C (-60°F to +221°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembly Weight:\u003c\/strong\u003e 1.2 kg (2.65 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Selection Comparison \u0026amp; Application Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEvaluate the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e alongside the closely related \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/32000-29-05-10-072-07-02-bently-nevada-metric-proximity-probe-housing\"\u003e\u003cstrong\u003e32000-29-05-10-072-07-02\u003c\/strong\u003e\u003c\/a\u003e assembly to ensure dimensional and conduit compatibility with your machine casing:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection Parameter\u003c\/th\u003e\n\u003cth\u003e\n\u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e (Current Model)\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/32000-29-05-10-072-07-02-bently-nevada-metric-proximity-probe-housing\"\u003e\u003cstrong\u003e32000-29-05-10-072-07-02\u003c\/strong\u003e\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOption 28:\u003c\/strong\u003e 3300 XL 8 mm probe, multiple approvals\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOption 29:\u003c\/strong\u003e Alternate 3300 XL probe \/ approval configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in) (Option 05)\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in) (Option 05)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e50 mm\u003c\/strong\u003e (Option 05)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e100 mm\u003c\/strong\u003e (Option 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e110 mm\u003c\/strong\u003e (Option 110)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e72 mm\u003c\/strong\u003e (Option 072)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConduit Fittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOption 03:\u003c\/strong\u003e Two plugs, one M20 fitting, armored cable seal grip\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOption 07:\u003c\/strong\u003e Alternate conduit \/ explosion-proof fitting kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (Option 02)\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT (Option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing Depth \u0026amp; Standoff Geometry:\u003c\/strong\u003e Select the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e when your machine bearing housing requires deeper radial reach (110 mm probe penetration) paired with a compact 50 mm external standoff. Choose \u003ca href=\"https:\/\/www.plcsparehub.com\/products\/32000-29-05-10-072-07-02-bently-nevada-metric-proximity-probe-housing\"\u003e\u003cstrong\u003e32000-29-05-10-072-07-02\u003c\/strong\u003e\u003c\/a\u003e when thick thermal insulation blankets or external guards demand a longer 100 mm external standoff with a shallower 72 mm internal penetration depth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Exit \u0026amp; Conduit Standards:\u003c\/strong\u003e The \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e comes pre-configured with an M20 metric entry and an armored cable seal grip with grommets, making it ideal for IEC metric plant installations routing armored extension cables directly out of the housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eField Commissioning \u0026amp; Maintenance Protocol\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eApply suitable thread sealant to the \u003cstrong\u003e3\/4-14 NPT\u003c\/strong\u003e standoff adapter before threading into the machine casing port to prevent lube-oil weeping.\u003c\/li\u003e\n\u003cli\u003eAdjust the internal probe sleeve depth to achieve the nominal -9.0 to -10.0 Vdc gap voltage against the AISI 4140 rotor shaft, then lock the adjustment collar securely.\u003c\/li\u003e\n\u003cli\u003eSeat the Neoprene® cover O-ring cleanly and fasten the AISI 303 stainless steel cover bolts to preserve the IP66 \/ Type 4X environmental barrier.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eRotating Machinery Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e32000-28-05-05-110-03-02\u003c\/strong\u003e\u003c\/span\u003e utilize conductive-fiber PPS thermoplastic instead of standard cast aluminum?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Glass-reinforced PPS with conductive fibers satisfies CENELEC EN50014 electrostatic dissipation requirements for hazardous areas while offering superior chemical resistance against sour gas, salt spray, and synthetic turbine oils without galvanic corrosion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the AISI 304 stainless steel retaining chain integrated into the assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The retaining chain tethers the removable housing cover to the main body, preventing technicians from dropping or losing the lid inside grated turbine decks or elevated compressor platforms during live gap adjustments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can technicians gap or replace the 3300 XL 8 mm probe while the turbine or compressor is running at full load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The external sleeve and standoff isolation design allow maintenance crews to unscrew the weatherproof cover, loosen the internal probe clamp, and adjust or swap the transducer safely without breaching bearing oil seals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the 3\/4-14 NPT mounting thread (Option 02) mandatory whenever a Standoff Adapter Option is specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The standoff adapter bridges the mechanical gap between the machine case and the housing base; the heavy-duty 3\/4-14 NPT tapered thread provides the structural rigidity required to resist cantilever vibration fatigue on high-speed machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the armored cable seal grip in Fittings Option 03 protect the coaxial connection inside the housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The compression grommet clamps tightly around the stainless steel armor of the extension cable, providing mechanical strain relief and preventing washdown water or oil mist from entering through the M20 conduit port.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Vertical_and_Horizontal_Profile_Views_of_the_31000_and_32000_Proximity_Probe_Housings_75428f53-058c-442d-8cea-6ca5f41108d6.png?v=1778221547\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013942272182,"sku":"32000-28-05-05-110-03-02","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/32000-3_897bd5a2-c946-4e91-84c3-308a4eb08889.jpg?v=1792467569","url":"https:\/\/www.plcsparehub.com\/products\/32000-28-05-05-110-03-02-bently-nevada-32000-metric-proximity-probe-housing","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}