{"product_id":"31000-16-05-35-026-03-02-bently-nevada-proximity-probe-housing","title":"31000-16-05-35-026-03-02 Bently Nevada Proximity Probe Housing","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada 31000-16-05-35-026-03-02 | 31000 Proximity Probe Housing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e74b5;\"\u003e31000-16-05-35-026-03-02\u003c\/span\u003e\u003c\/strong\u003e is a Bently Nevada 31000 proximity probe housing assembly designed to protect a compatible 3300 XL 8 mm probe in industrial machinery monitoring installations. Its housing, stainless steel sleeve, cable sealing components, and threaded fittings support probe installation where environmental protection and controlled cable entry are important.\u003c\/p\u003e\n\u003cp\u003eThis configuration specifies a 0.5 m (20 in) probe cable, a 3.5 in standoff adapter, 2.6 in probe penetration, and a 3\/4-14 NPT mounting thread. The assembly uses a glass-reinforced PPS thermoplastic housing with conductive fibers and stainless steel external hardware.\u003c\/p\u003e\n\u003cp\u003eFor maintenance and instrumentation engineers, the key selection factors are probe compatibility, required penetration, available mounting clearance, cable diameter, conduit or fitting arrangement, and the environmental conditions around the machine. The housing provides environmental protection; it is not a pressure vessel.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown | Read the Part Number as a Build Specification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e31000\u003c\/strong\u003e — 31000 series proximity probe housing assembly\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-16\u003c\/strong\u003e — Probe option with connector: 3300 XL 8 mm probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e — Probe cable length: 0.5 m (20 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-35\u003c\/strong\u003e — Standoff adapter length: 3.5 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-026\u003c\/strong\u003e — Probe penetration: 2.6 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-03\u003c\/strong\u003e — Fittings configuration:\n\u003cul\u003e\n\u003cli\u003eTwo plugs\u003c\/li\u003e\n\u003cli\u003eOne 3\/4-14 NPT fitting\u003c\/li\u003e\n\u003cli\u003eOne 3\/4-14 to 1\/2-14 NPT stainless steel reducer\u003c\/li\u003e\n\u003cli\u003eOne cable seal grip with grommets for cable diameters of 1\/8–3\/16 in, 1\/4–5\/16 in, and 5\/16–3\/8 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e — Mounting thread: 3\/4-14 NPT, required for the specified standoff adapter option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering checkpoint:\u003c\/strong\u003e Confirm every suffix against the installed assembly and mounting drawing. In particular, do not confuse the 0.5 m probe cable length with the 2.6 in probe penetration or the 3.5 in standoff adapter length. These dimensions describe different parts of the installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31000-16-05-35-026-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31000 Proximity Probe Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe, as specified by option -16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe cable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFittings option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-03; two plugs, one 3\/4-14 NPT fitting, one stainless steel 3\/4-14 to 1\/2-14 NPT reducer, and cable seal grip with grommets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGlass-reinforced PPS thermoplastic containing conductive fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSleeve and retaining chain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter sleeve and exterior screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO-ring material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeoprene for the sleeve-to-housing seal; the probe case uses a Viton O-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType 4X certified by CSA; IP66 rating verified by the referenced test documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +105°C (-60°F to +221°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetaining nut torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.4 N·m (260 in·lb), per supplied specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpact resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBASEEFA certification for two separate 4 J impacts at -39°C and 115°C; CSA sample verification at 7 J under ambient conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (2.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA, according to the supplied product information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Design and Environmental Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe housing combines a glass-reinforced PPS body with stainless steel sleeve components to support industrial probe mounting. Conductive fibers in the thermoplastic are part of the stated housing construction and relate to the material's electrostatic-dissipation requirements in applicable hazardous-area installations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental sealing:\u003c\/strong\u003e The housing is certified for Type 4X protection and has an IP66 rating according to the supplied documentation. These ratings address environmental ingress protection, not resistance to internal or external process pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical support:\u003c\/strong\u003e The sleeve, retaining chain, and external hardware provide the mechanical mounting arrangement. Verify mounting support and clearance against the installation drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable entry:\u003c\/strong\u003e The supplied seal grip and grommets cover specified cable diameter ranges. Select the grommet that matches the actual cable outside diameter to avoid a poor seal or cable movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeal materials:\u003c\/strong\u003e The sleeve-to-housing seal uses Neoprene, while the probe case seal uses Viton. Confirm material suitability if the installation exposes the assembly to unusual chemicals or cleaning agents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePressure limitation:\u003c\/strong\u003e The assembly is designed to seal differential pressure between the probe tip and housing body when used with a compatible 3300 XL 8 mm probe. However, the plastic housing is not designed to resist internal or external pressure. The probes are not pressure-tested before shipment. If an application requires pressure-seal verification, obtain the manufacturer's approved test procedure before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam and gas turbines:\u003c\/strong\u003e Houses a compatible proximity probe used for shaft displacement measurement when the machine's probe mounting arrangement supports this housing configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal compressors:\u003c\/strong\u003e Supports probe installation for shaft vibration and position monitoring in compatible machinery protection systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial pumps:\u003c\/strong\u003e Provides an environmentally protected mounting arrangement for non-contact shaft measurement where the probe location and dimensions match the design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotors and rotating machinery:\u003c\/strong\u003e Can be used where the equipment design requires a compatible 3300 XL 8 mm probe and a protected housing assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor or washdown-prone installations:\u003c\/strong\u003e The stated Type 4X and IP66 protection ratings may be relevant, provided the complete installation meets the site's environmental and hazardous-area requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication suitability depends on the machine design, mounting geometry, probe target, operating temperature, and installation certification. Do not infer suitability for a pressurized process boundary from the environmental protection ratings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the mounting location:\u003c\/strong\u003e Verify the 3\/4-14 NPT thread, 3.5 in standoff adapter, and available clearance before fitting the assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm penetration:\u003c\/strong\u003e Compare the 2.6 in penetration option with the machine drawing and the required probe-to-target geometry. Do not use the penetration dimension as a substitute for the probe gap setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFit the correct cable grommet:\u003c\/strong\u003e Measure the cable's actual outside diameter and select the matching supplied grommet range. Ensure the cable seal grip is correctly assembled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApply the specified torque:\u003c\/strong\u003e The supplied retaining-nut torque is 29.4 N·m (260 in·lb). Apply it only to the specified retaining nut and follow the applicable installation instructions; do not apply it indiscriminately to every threaded fitting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the seals:\u003c\/strong\u003e Check the O-rings and mating surfaces for damage, contamination, or incorrect seating before closing the housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify system operation:\u003c\/strong\u003e After installation, check the probe gap and signal using the approved procedure for the connected Proximitor sensor and machinery monitor.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFollow the equipment manufacturer's procedures and site lockout requirements before working near rotating machinery. For hazardous-area service, confirm the complete installation method and applicable certification documents.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Diagnostics | Separate Housing Faults from Measurement Faults\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eObserved symptom\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended checks\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture or contamination inside the housing\u003c\/td\u003e\n\u003ctd\u003eInspect the cover seal, cable grommet fit, unused port plugs, and fitting threads. Check whether the assembly was closed correctly after maintenance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable moves within the seal grip\u003c\/td\u003e\n\u003ctd\u003eVerify the cable outside diameter and grommet selection. Inspect the grip assembly and cable jacket for damage before retightening according to the approved procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe penetration does not match the drawing\u003c\/td\u003e\n\u003ctd\u003eConfirm the -026 penetration option, -35 standoff adapter, mounting datum, and machine-side clearance. Do not compensate for a dimensional mismatch by forcing the probe into position.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent vibration or gap readings\u003c\/td\u003e\n\u003ctd\u003eInspect the probe connector and cable, then verify probe mounting stability, gap setting, and compatibility with the Proximitor sensor. The housing itself does not generate the measurement signal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamage after impact or maintenance\u003c\/td\u003e\n\u003ctd\u003eCheck the housing body, cover, sleeve, fittings, and seal surfaces for cracks, deformation, or looseness. Replace damaged components according to the manufacturer's service instructions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcern about pressure leakage\u003c\/td\u003e\n\u003ctd\u003eDo not treat IP66 or Type 4X as pressure-vessel certification. Confirm the application's pressure boundary and arrange an approved seal test if required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic principle:\u003c\/strong\u003e This assembly protects and positions the proximity probe. It does not independently measure vibration or diagnose machine condition. For signal faults, troubleshoot the probe, cable, Proximitor sensor, monitor channel, target surface, and installation geometry as one measurement chain.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Comparison: 31000-16-05-35-026-03-02 vs. 31000-28-05-15-042-06-02\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the linked alternative below to compare the two housing configurations. The detailed suffix definitions supplied here apply to \u003cstrong\u003e31000-16-05-35-026-03-02\u003c\/strong\u003e; verify the alternative's complete configuration against its official drawing before assuming the suffixes have identical meanings.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31000-16-05-35-026-03-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.plcsparehub.com\/products\/31000-28-05-15-042-06-02-bently-nevada-31000-proximity-housing\"\u003e31000-28-05-15-042-06-02\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31000 Proximity Probe Housing\u003c\/td\u003e\n\u003ctd\u003e31000 Proximity Probe Housing, based on the listed model reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-16 specifies a 3300 XL 8 mm probe with connector\u003c\/td\u003e\n\u003ctd\u003eOption -28 requires confirmation from the applicable configuration documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe cable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in)\u003c\/td\u003e\n\u003ctd\u003eSuffix -05 appears in the part number; verify the option definition against the official configuration table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandoff adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 in\u003c\/td\u003e\n\u003ctd\u003eSuffix -15 differs; confirm the adapter dimension before selecting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe penetration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6 in\u003c\/td\u003e\n\u003ctd\u003eSuffix -042 differs; verify the penetration dimension and its reference datum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFittings arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-03: two plugs, one 3\/4-14 NPT fitting, one stainless steel reducer, and cable seal grip with grommets\u003c\/td\u003e\n\u003ctd\u003e-06 differs; confirm the supplied fittings, port sizes, and cable sealing components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003ctd\u003eSuffix -02 appears in the part number; confirm the mounting thread and compatibility with the selected adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Recommendation for Choosing Between the Two\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose 31000-16-05-35-026-03-02\u003c\/strong\u003e when the installation drawing requires a 3300 XL 8 mm probe, a 0.5 m cable, a 3.5 in standoff adapter, 2.6 in penetration, and the specified -03 fittings arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvaluate 31000-28-05-15-042-06-02\u003c\/strong\u003e when its verified probe option, standoff length, penetration, fittings, or mounting arrangement better matches the existing machine installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore substituting either model,\u003c\/strong\u003e compare the mounting drawing, actual probe and cable arrangement, port threads, grommet sizes, temperature rating, seal materials, and required environmental or hazardous-area approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe part-number differences indicate that the configurations should not be treated as interchangeable without documentation. If the original assembly is being replaced, use the installed part number and equipment drawing to verify each mechanical interface before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHousing replacement errors often arise when a technician checks the probe family but overlooks penetration depth, standoff length, or cable entry details. These dimensions determine whether the probe reaches its intended measurement position and whether the housing can be sealed correctly.\u003c\/p\u003e\n\u003cp\u003eFor this configuration, confirm the 2.6 in penetration and 3.5 in standoff adapter against the machine drawing first. Next, check the cable outside diameter against the supplied grommet ranges, inspect the Neoprene seal, and verify the specified retaining-nut torque. After installation, validate the measurement signal through the connected probe, Proximitor sensor, and monitor channel.\u003c\/p\u003e\n\u003cp\u003eAlso distinguish environmental sealing from pressure containment. Type 4X and IP66 ratings do not make this housing suitable for resisting internal or external pressure. Applications that require pressure-seal verification need an approved test and documented acceptance criteria.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackage Contents and Order Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Bently Nevada 31000-16-05-35-026-03-02 housing assembly, subject to order confirmation.\u003c\/li\u003e\n\u003cli\u003eFittings and cable-sealing components according to the specified -03 configuration.\u003c\/li\u003e\n\u003cli\u003eAny additional probe, sensor, cable, or mounting hardware must be confirmed in the quotation unless explicitly included.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty, subject to the supplier's written terms and conditions. Confirm the applicable coverage with the sales team before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL are available subject to destination, carrier service, and order processing. Confirm shipping arrangements and dispatch timing with the supplier for urgent maintenance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest a quote:\u003c\/strong\u003e Provide the full part number, quantity, destination, probe model, and mounting drawing where available. For a substitute housing, include the installed configuration and dimensions so the team can help review mechanical and system compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How can I confirm that the 2.6 in penetration will place the probe correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the housing and probe dimensions with the machine drawing, including the mounting datum, target location, and available clearance. Penetration is a mechanical dimension, not the operating gap between the probe tip and the shaft. Confirm the final gap using the approved commissioning procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What happens if the cable diameter falls between the listed grommet ranges?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not force the cable into a grommet that does not fit. Measure the cable's actual outside diameter and confirm an approved sealing solution with the supplier or manufacturer. An unsuitable grommet can compromise cable retention and environmental sealing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can IP66 or Type 4X protection be used as evidence that the housing can withstand process pressure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. These ratings relate to environmental protection, not pressure-vessel capability. The supplied specifications explicitly state that the housing is not designed to resist internal or external pressure. Review the process boundary separately and request an approved pressure-seal test when the application requires one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which installation checks are most useful after replacing the housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the mounting thread, adapter and penetration dimensions, cable grip, seal condition, cover closure, and retaining-nut torque. Then verify the probe gap and signal through the connected Proximitor sensor and monitor. Record the final readings to establish a useful maintenance baseline.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What information should I send when requesting a replacement or an alternative model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full existing part number, the proposed replacement number, the probe model, mounting drawing, measured penetration and standoff dimensions, cable outside diameter, and site temperature or environmental requirements. Include hazardous-area requirements where applicable. This information helps the supplier assess fit and avoid an unverified substitution.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Vertical_and_Horizontal_Profile_Views_of_the_31000_and_32000_Proximity_Probe_Housings_75428f53-058c-442d-8cea-6ca5f41108d6.png?v=1778221547\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013941813430,"sku":"31000-16-05-35-026-03-02","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/32000-3_897bd5a2-c946-4e91-84c3-308a4eb08889.jpg?v=1792467569","url":"https:\/\/www.plcsparehub.com\/products\/31000-16-05-35-026-03-02-bently-nevada-proximity-probe-housing","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}