{"product_id":"2mlq-ry2a-honeywell-masterlogic-200-series-relay-output-module","title":"2MLQ-RY2A Honeywell MasterLogic-200 Series Relay Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Introduction | Relay-Based Output Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003e2MLQ-RY2A\u003c\/strong\u003e\u003c\/span\u003e is a Honeywell digital output module designed for industrial control applications. It provides \u003cstrong\u003e16 relay-isolated output points\u003c\/strong\u003e for switching external AC and DC loads.\u003c\/p\u003e\n\u003cp\u003eUnlike transistor output modules, this relay-based design supports different load voltage types. It handles resistive and specified inductive loads within its rated electrical limits.\u003c\/p\u003e\n\u003cp\u003eEach output uses mechanical relay contacts for electrical switching. The module provides one common terminal per 16-point output group. An 18-point terminal block supports field wiring and electrical connections.\u003c\/p\u003e\n\u003cp\u003eWith a mechanical life exceeding 20 million operations, this module supports repetitive switching applications. Its LED indicators also help technicians identify active output states during commissioning and troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Identity \u0026amp; Core Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003e2MLQ-RY2A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMasterLogic-200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Points \/ 1 COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA with all outputs ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput ON LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-Point Terminal Block Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Screw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM3 × 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003e01 | Electrical Switching Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe relay contacts support AC and DC switching within specified voltage and current limits. Engineers should evaluate load characteristics before assigning output circuits.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Resistive Load\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Resistive Load\u003c\/td\u003e\n\u003ctd\u003e220 VAC \/ 2 A, COS φ = 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.1 mA at 220 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e3,600 operations per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Absorber\u003c\/td\u003e\n\u003ctd\u003eNot provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Note:\u003c\/strong\u003e The maximum switching voltage does not represent the maximum rated operating load. Always observe the specified voltage, current, and load-type limitations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e02 | Contact Endurance and Switching Life\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eRelay contact endurance depends on electrical loading, switching frequency, and load power factor. The following values describe the specified service-life conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Service Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd\u003e20 million operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated AC Resistive Load: 220 VAC \/ 2 A\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 200 V \/ 1.5 A, AC 240 V \/ 1 A, COS φ = 0.7\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC 200 V \/ 1 A, AC 240 V \/ 0.5 A, COS φ = 0.35\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC 24 V \/ 1 A, DC 100 V \/ 0.1 A, L\/R = 7 ms\u003c\/td\u003e\n\u003ctd\u003e100,000 operations or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eContact Life Consideration:\u003c\/strong\u003e Mechanical endurance and electrical endurance represent different test conditions. Electrical contact wear increases with switching current and inductive loading.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e03 | Response Characteristics and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOutput response time affects the coordination between PLC logic and external equipment. The specified switching delays are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON:\u003c\/strong\u003e 10 ms or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF:\u003c\/strong\u003e 12 ms or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Monitoring:\u003c\/strong\u003e Individual output ON indication through LED status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Method:\u003c\/strong\u003e Electromechanical relay contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe LED indicator provides a convenient visual reference during field troubleshooting. It helps technicians compare PLC output commands with the module's indicated operating state.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e04 | Field Wiring and Installation Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003e2MLQ-RY2A\u003c\/strong\u003e\u003c\/span\u003e uses an 18-point terminal block connector. Its output arrangement provides 16 switching points and one common terminal group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Installation Procedure:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the module model and controller slot assignment.\u003c\/li\u003e\n\u003cli\u003eDisconnect field power before handling terminal wiring.\u003c\/li\u003e\n\u003cli\u003eIdentify each output point and its common connection.\u003c\/li\u003e\n\u003cli\u003eCheck load voltage and current against the electrical ratings.\u003c\/li\u003e\n\u003cli\u003eSeparate AC and DC wiring according to cabinet design requirements.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections and tighten screws appropriately.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring before energizing external loads.\u003c\/li\u003e\n\u003cli\u003eTest each output channel individually during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Wiring Precautions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe module does not include a built-in surge absorber.\u003c\/li\u003e\n\u003cli\u003eInductive loads may generate switching transients.\u003c\/li\u003e\n\u003cli\u003eUse suitable external suppression where the application requires it.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the specified contact voltage or current.\u003c\/li\u003e\n\u003cli\u003eCheck the common terminal arrangement before connecting multiple loads.\u003c\/li\u003e\n\u003cli\u003eFollow the controller manufacturer's installation and grounding instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e05 | Application Engineering and Selection Guidance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis relay output design suits control circuits that require mechanical contact switching. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Switching compatible contactor control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Control:\u003c\/strong\u003e Operating suitable solenoid valve circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Machinery:\u003c\/strong\u003e Controlling auxiliary equipment and actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Automation:\u003c\/strong\u003e Switching external alarm and interlock circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Panels:\u003c\/strong\u003e Controlling compatible AC and DC loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Sequencing:\u003c\/strong\u003e Operating multiple field devices through PLC logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSelection Advice:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChoose this module when your application requires relay contacts and compatible AC\/DC switching. Check load inrush current, power factor, switching frequency, and expected operating cycles before final selection.\u003c\/p\u003e\n\u003cp\u003eFor high-frequency switching applications, evaluate the maintenance impact of mechanical contact wear. A transistor output module may suit applications requiring faster repetitive switching, but it does not provide identical electrical characteristics.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e06 | Commissioning and Maintenance Recommendations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper commissioning helps identify wiring errors and excessive contact loading before normal production begins.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Checklist:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify module identification and installation position.\u003c\/li\u003e\n\u003cli\u003eConfirm output addressing in the PLC configuration.\u003c\/li\u003e\n\u003cli\u003eCheck the common terminal wiring.\u003c\/li\u003e\n\u003cli\u003eMeasure external load voltage before activation.\u003c\/li\u003e\n\u003cli\u003eTest output switching one channel at a time.\u003c\/li\u003e\n\u003cli\u003eCompare PLC commands with LED indications.\u003c\/li\u003e\n\u003cli\u003eVerify the OFF-state condition of connected equipment.\u003c\/li\u003e\n\u003cli\u003eInspect external suppression devices where applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePreventive Maintenance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspect terminal blocks for looseness and overheating.\u003c\/li\u003e\n\u003cli\u003eReview output switching frequency and operating cycles.\u003c\/li\u003e\n\u003cli\u003eCheck relay contact performance when loads become intermittent.\u003c\/li\u003e\n\u003cli\u003eInvestigate unexpected voltage or current fluctuations.\u003c\/li\u003e\n\u003cli\u003eRecord channel failures and replacement history.\u003c\/li\u003e\n\u003cli\u003eCheck inductive load suppression components periodically.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRelay contacts can wear even when the LED indicates normal output operation. Investigate the external load circuit whenever commanded switching does not produce the expected field response.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e07 | Compatibility and Replacement Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBefore ordering \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003e2MLQ-RY2A\u003c\/strong\u003e\u003c\/span\u003e, verify the following points against the installed control system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Family:\u003c\/strong\u003e Confirm the MasterLogic-200 hardware configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type:\u003c\/strong\u003e Verify relay output requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Count:\u003c\/strong\u003e Confirm the requirement for 16 output points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Arrangement:\u003c\/strong\u003e Check the 16-point \/ 1COM configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Loading:\u003c\/strong\u003e Match AC\/DC voltage and current requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Interface:\u003c\/strong\u003e Verify the 18-point connector arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Logic:\u003c\/strong\u003e Confirm PLC addressing and output assignment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Warning:\u003c\/strong\u003e Do not select a substitute based only on channel count. Relay and transistor modules may have different wiring, load characteristics, response times, and electrical isolation arrangements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e8 | Packaging and Supply Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eHoneywell Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2MLQ-RY2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connector\u003c\/td\u003e\n\u003ctd\u003e18-Point Terminal Block Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Accessories\u003c\/td\u003e\n\u003ctd\u003eConfirm separately before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eContact our sales team to confirm the supplied connector, accessories, and packaging configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can all 16 output channels operate simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specification identifies 500 mA current consumption when all 16 points are ON. However, simultaneous operation must also satisfy each contact's electrical load rating and the controller system's power and thermal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why can a relay output show an ON indication without operating the connected device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe LED indicates the module's output status, not the complete health of the external circuit. Check the field supply, common wiring, terminal connections, relay contacts, and load condition before replacing the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should engineers consider when switching solenoid valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSolenoid coils produce inductive switching transients. Evaluate the coil's voltage, current, and suppression requirements. The module has no built-in surge absorber, so suitable external protection may be necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should maintenance teams identify deteriorating relay contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLook for intermittent switching, abnormal contact voltage drops, unstable load operation, or inconsistent output performance. Compare measurements under actual operating conditions and review the switching history before scheduling replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is this module suitable for high-speed pulse output applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is not intended as a high-speed pulse output device. Its electromechanical contacts have switching delays of up to 10 ms and 12 ms. Frequent switching also increases contact wear. Select an appropriate transistor output solution for high-frequency applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Source Honeywell 2MLQ-RY2A From Us?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Identification:\u003c\/strong\u003e Assistance with model and specification verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Support:\u003c\/strong\u003e Help with output type and load compatibility checks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e International delivery options through DHL, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTechnical Assistance:\u003c\/strong\u003e Support for industrial automation spare-part selection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLooking for the \u003cspan style=\"color: #1673b9;\"\u003e\u003cstrong\u003eHoneywell 2MLQ-RY2A\u003c\/strong\u003e\u003c\/span\u003e? Contact us with your required quantity and delivery destination. Request a quotation for pricing, availability, and technical assistance.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68027745108150,"sku":"2MLQ-RY2A","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2MLQ-RY2A-1.jpg?v=1794279721","url":"https:\/\/www.plcsparehub.com\/products\/2mlq-ry2a-honeywell-masterlogic-200-series-relay-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}