{"product_id":"2711p-t10c21d8s-allen-bradley-10-4-inch-panelview-plus-7","title":"2711P-T10C21D8S Allen-Bradley 10.4-Inch PanelView Plus 7","description":"\u003ch3\u003e\u003cb\u003eAllen-Bradley 2711P-T10C21D8S | PanelView Plus 7 Graphic Terminal\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cb\u003eAllen-Bradley 2711P-T10C21D8S\u003c\/b\u003e is a 10.4-inch color graphic terminal in the PanelView Plus 7 product family. It provides a touchscreen operator interface for displaying machine conditions, process values, alarms, and control screens within a compatible industrial automation system.\u003c\/p\u003e\n\n\u003cp\u003eThe terminal uses a color TFT LCD with 800 × 600 SVGA resolution and 18-bit color graphics. Its 4:3 display format supports established HMI screen layouts, while the touch interface allows operators to interact with configured controls and process information.\u003c\/p\u003e\n\n\u003cp\u003eWith 512 MB of RAM, 512 MB of system storage, and 80 MB of nonvolatile application storage, the terminal provides resources for its supported HMI runtime environment. The 18–30 V DC input range supports compatible industrial DC power supplies.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e01 | HMI Interface Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThink of the 2711P-T10C21D8S as the operator-facing layer of a machine control system. Its role is to present information and accept operator input; the PLC or other configured control system performs the underlying control logic.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVisual layer\u003c\/b\u003e\n  \u003cul\u003e\n    \u003cli\u003e10.4-inch diagonal color TFT LCD\u003c\/li\u003e\n    \u003cli\u003e800 × 600 SVGA resolution\u003c\/li\u003e\n    \u003cli\u003e18-bit color graphics and 4:3 aspect ratio\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperator interaction layer\u003c\/b\u003e\n  \u003cul\u003e\n    \u003cli\u003eTouchscreen input\u003c\/li\u003e\n    \u003cli\u003eRated for 1 million touch actuations, according to the supplied specification\u003c\/li\u003e\n    \u003cli\u003eSupports interaction with configured HMI objects and controls\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSystem resource layer\u003c\/b\u003e\n  \u003cul\u003e\n    \u003cli\u003e512 MB RAM\u003c\/li\u003e\n    \u003cli\u003e512 MB system storage\u003c\/li\u003e\n    \u003cli\u003e80 MB nonvolatile storage allocated for applications, according to the supplied specification\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower interface\u003c\/b\u003e\n  \u003cul\u003e\n    \u003cli\u003e18–30 V DC input range\u003c\/li\u003e\n    \u003cli\u003eMaximum stated power consumption of 50 W\u003c\/li\u003e\n    \u003cli\u003eSpecified current draw of 2.1 A at 24 V DC\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e02 | Technical Specification Sheet\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e2711P-T10C21D8S\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003ePanelView Plus 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eGraphic terminal \/ HMI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay technology\u003c\/td\u003e\n\u003ctd\u003eColor TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay size\u003c\/td\u003e\n\u003ctd\u003e10.4 inches diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eViewing area\u003c\/td\u003e\n\u003ctd\u003e211 × 158 mm (W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e800 × 600 SVGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor graphics\u003c\/td\u003e\n\u003ctd\u003e18-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAspect ratio\u003c\/td\u003e\n\u003ctd\u003e4:3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator input\u003c\/td\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch actuation rating\u003c\/td\u003e\n\u003ctd\u003e1 million presses, as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem memory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem storage\u003c\/td\u003e\n\u003ctd\u003e512 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication storage\u003c\/td\u003e\n\u003ctd\u003e80 MB nonvolatile storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e18–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum power consumption\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified current at 24 V DC\u003c\/td\u003e\n\u003ctd\u003e2.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.94 lb (2.24 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e885630920528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003e03 | Display Performance and Screen Design\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe 800 × 600 SVGA resolution and 4:3 aspect ratio are important when assessing a replacement for an existing HMI. Screen proportions affect the placement of process graphics, navigation controls, alarm lists, and operator input fields.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eScreen layout:\u003c\/b\u003e Check the original application's resolution and aspect ratio before migrating or restoring an HMI project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eGraphic readability:\u003c\/b\u003e Review text size, alarm visibility, color contrast, and the spacing of touch targets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTouch operation:\u003c\/b\u003e Confirm that frequently used controls remain accessible and respond consistently across the active display area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eApplication compatibility:\u003c\/b\u003e Verify the project version, runtime requirements, and supported features for the specific terminal before transferring an application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eEngineering note:\u003c\/b\u003e A matching screen size does not guarantee project compatibility. Resolution, runtime software, communication configuration, and the application itself must also be checked.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e04 | DC Power Design and Verification\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Check\u003c\/th\u003e\n\u003cth\u003eSpecification or Action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput range\u003c\/td\u003e\n\u003ctd\u003e18–30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference supply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecified current at 24 V DC\u003c\/td\u003e\n\u003ctd\u003e2.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum stated power\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply sizing\u003c\/td\u003e\n\u003ctd\u003eAllow for the HMI load and other connected devices on the same power supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage verification\u003c\/td\u003e\n\u003ctd\u003eMeasure the voltage at the terminal under load, not only at the power supply output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring inspection\u003c\/td\u003e\n\u003ctd\u003eCheck polarity, terminal security, conductor condition, and voltage drop.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eAt the specified 24 V DC operating point, the stated current draw is 2.1 A. When designing the panel supply, consider startup conditions, wiring losses, and other connected loads. Do not size the supply using the nominal voltage alone.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eCommissioning check:\u003c\/b\u003e If the display restarts or becomes unstable during machine operation, measure the voltage at the HMI while other equipment is switching. A supply that appears correct at idle may experience a voltage drop under load.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e05 | Where This Graphic Terminal Fits\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging and filling machines:\u003c\/b\u003e Displays operating status, production settings, alarms, and operator commands configured in the HMI application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaterial handling systems:\u003c\/b\u003e Provides a local interface for conveyor status, machine sequences, fault messages, and maintenance screens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndustrial process skids:\u003c\/b\u003e Presents process values, operating modes, alarm conditions, and operator instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAssembly and test stations:\u003c\/b\u003e Supports operator prompts, production status screens, and configured machine interactions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePLC control cabinets:\u003c\/b\u003e Serves as the local operator interface for compatible controllers and supported HMI applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance and retrofit projects:\u003c\/b\u003e Can be considered as a replacement terminal when the catalog number, application requirements, and system configuration have been verified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe terminal's actual functions depend on the loaded application and the connected control system. Do not assume that every application provides the same alarms, trends, recipe functions, or communication features.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e06 | Application Migration and Replacement Planning\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eReplacing an existing HMI involves more than matching the display dimensions. Before ordering, check the following engineering details.\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eCatalog number:\u003c\/b\u003e Confirm the complete part number on the existing unit or equipment documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProject availability:\u003c\/b\u003e Locate the original HMI project, runtime files, and any required development software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRuntime compatibility:\u003c\/b\u003e Verify the project version and supported functions against the target terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eController communications:\u003c\/b\u003e Check the controller model, communication settings, network configuration, and required drivers against the system documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eScreen behavior:\u003c\/b\u003e Verify screen resolution, navigation, alarm presentation, and operator input behavior during testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBackup and recovery:\u003c\/b\u003e Back up the existing project and record current settings before replacing the terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSite acceptance:\u003c\/b\u003e Test normal operation, alarms, interlocks, and operator permissions before returning the machine to production.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e The supplied specifications do not establish all communication interfaces, software versions, certifications, or environmental ratings for this exact catalog number. Confirm those details in the applicable manufacturer documentation before finalizing a retrofit design.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e07 | Fault Isolation Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003eLikely Areas to Investigate\u003c\/th\u003e\n\u003cth\u003eRecommended Diagnostic Sequence\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal does not power up\u003c\/td\u003e\n\u003ctd\u003eDC supply, polarity, wiring, or terminal connection\u003c\/td\u003e\n\u003ctd\u003eMeasure the voltage at the HMI under load. Verify polarity and inspect the power wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay restarts intermittently\u003c\/td\u003e\n\u003ctd\u003eVoltage drop, unstable power supply, loose wiring, or other system faults\u003c\/td\u003e\n\u003ctd\u003eMonitor the DC supply during machine startup and switching events. Inspect connections and supply loading.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch input is inconsistent\u003c\/td\u003e\n\u003ctd\u003eTouchscreen condition, contamination, application layout, or software behavior\u003c\/td\u003e\n\u003ctd\u003eInspect and clean the display according to approved instructions. Test different screen regions and review the application configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen content is missing or incorrect\u003c\/td\u003e\n\u003ctd\u003eIncorrect project, incompatible runtime, or application configuration problem\u003c\/td\u003e\n\u003ctd\u003eVerify the loaded project, runtime version, screen settings, and project backup.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI cannot communicate with the controller\u003c\/td\u003e\n\u003ctd\u003eNetwork wiring, controller availability, addressing, driver, or communication settings\u003c\/td\u003e\n\u003ctd\u003eCheck physical connections and controller status. Verify the configured protocol, addressing, and application communication settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms or displayed values do not match the process\u003c\/td\u003e\n\u003ctd\u003eController tags, application logic, data mapping, or stale communication\u003c\/td\u003e\n\u003ctd\u003eCompare the HMI display with controller-side values and review tag assignments and communication status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement terminal fails application acceptance\u003c\/td\u003e\n\u003ctd\u003eProject incompatibility, missing configuration, or different system settings\u003c\/td\u003e\n\u003ctd\u003eRestore the correct project version, verify the system configuration, and complete the site's functional test procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cb\u003eDiagnostic approach:\u003c\/b\u003e Separate power faults, display or touch faults, communication faults, and application faults. This prevents unnecessary hardware replacement when the actual cause is a project or configuration issue.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e08 | Global PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFor a PanelView replacement, the most important checks are the complete catalog number, application compatibility, controller communication settings, and power requirements. A terminal may power on correctly but still fail to operate the machine if the original HMI project or communication configuration is unavailable.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eFor maintenance teams:\u003c\/b\u003e Back up the application and record controller communication settings before removing the existing terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor system integrators:\u003c\/b\u003e Validate project compatibility and test operator commands, alarms, and critical screens before site handover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor purchasing teams:\u003c\/b\u003e Compare the complete model number rather than relying on the PanelView Plus 7 family name or screen size alone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor troubleshooting:\u003c\/b\u003e Confirm stable DC power first, then check communication and application behavior before deciding that the display hardware has failed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFor spare-parts planning:\u003c\/b\u003e Keep the original catalog number and project backup together with the machine's maintenance records.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003e09 | Frequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003eQ1. Can I transfer an existing PanelView application directly to this terminal?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eNot without checking compatibility. Confirm the original project version, target terminal configuration, runtime requirements, and supported features. Keep a verified backup and test the transferred application before connecting it to live equipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ2. What should I do if the HMI powers on but shows incorrect process values?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eCompare the displayed values with the controller's actual data. Then check tag assignments, controller addressing, communication status, and application configuration. A functioning display does not prove that the HMI is receiving the correct process data.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ3. How much capacity should I allow for the 24 V DC power supply?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe supplied data lists 2.1 A at 24 V DC and a maximum power consumption of 50 W. Account for the HMI load plus other devices on the same supply, wiring voltage drop, and suitable design margin. Verify the final supply requirements against the manufacturer's installation documentation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ4. Is a 10.4-inch display sufficient to confirm that this unit is the correct replacement?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. Screen size is only one matching criterion. Confirm the complete catalog number, resolution, aspect ratio, power requirements, application compatibility, and controller communication settings before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eQ5. What information should I send when requesting a replacement quotation?\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eProvide the full model number, required quantity, destination country, and whether the terminal is for a new project or an existing machine. For a replacement, include the current HMI project version if known, the controller model, and a photo of the product label. These details help identify compatibility questions before purchase.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003e10 | Ordering, Warranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e 2711P-T10C21D8S\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSeries:\u003c\/b\u003e PanelView Plus 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct type:\u003c\/b\u003e 10.4-inch Color Graphic Terminal \/ HMI\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12 months, subject to the seller's written warranty terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping carriers:\u003c\/b\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch target:\u003c\/b\u003e 24–48 hours after order confirmation, subject to stock availability and payment clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eRequest a quote for Allen-Bradley 2711P-T10C21D8S.\u003c\/b\u003e Send your required quantity, destination, and application or replacement details to help confirm the correct configuration before shipment.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67644147269814,"sku":"2711P-T10C21D8S","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2711P-T10C21D8S-1.jpg?v=1792045557","url":"https:\/\/www.plcsparehub.com\/products\/2711p-t10c21d8s-allen-bradley-10-4-inch-panelview-plus-7","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}