{"product_id":"25b-d2p3n104-powerflex-525-ac-drive-by-allen-bradley","title":"25B-D2P3N104 PowerFlex 525 AC Drive by Allen-Bradley","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Compact AC Motor Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eAllen-Bradley 25B-D2P3N104\u003c\/span\u003e\u003c\/strong\u003e is a \u003cstrong\u003ePowerFlex 525\u003c\/strong\u003e adjustable frequency AC drive manufactured by Rockwell Automation. It controls compatible three-phase AC motors by regulating output frequency and voltage.\u003c\/p\u003e\n\u003cp\u003eThis Frame A drive provides a 0.75 kW (1 HP) rating for both normal-duty and heavy-duty applications. Its embedded EtherNet\/IP interface supports integration with compatible industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eThe compact design suits standalone machines, distributed motor control panels, and existing production lines. Integrated safety features and programmable control modes help engineers adapt the drive to different machine requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Rockwell Automation \/ Allen-Bradley\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct family:\u003c\/strong\u003e PowerFlex 520 Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive series:\u003c\/strong\u003e PowerFlex 525\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog number:\u003c\/strong\u003e \u003cspan style=\"color: #1565c0;\"\u003e\u003cstrong\u003e25B-D2P3N104\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive category:\u003c\/strong\u003e Adjustable frequency AC drive \/ VFD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated motor power:\u003c\/strong\u003e 0.75 kW (1 HP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated output current:\u003c\/strong\u003e 2.3 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply class:\u003c\/strong\u003e 380–480 V AC, three-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork interface:\u003c\/strong\u003e Embedded EtherNet\/IP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications | Electrical and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e25B-D2P3N104\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct series\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 525, PowerFlex 520 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e380–480 V AC, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput frequency\u003c\/td\u003e\n\u003ctd\u003eConfirm the applicable nameplate and technical manual for the installation supply.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current\u003c\/td\u003e\n\u003ctd\u003eConfirm against the official technical data for the specific supply condition.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003eVariable three-phase AC output, up to the applicable drive voltage limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current\u003c\/td\u003e\n\u003ctd\u003e2.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal-duty rating\u003c\/td\u003e\n\u003ctd\u003e0.75 kW (1 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy-duty rating\u003c\/td\u003e\n\u003ctd\u003e0.75 kW (1 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFrame A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20, NEMA\/UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC filter\u003c\/td\u003e\n\u003ctd\u003eNo integral EMC filter in this catalog configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEmbedded EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface module\u003c\/td\u003e\n\u003ctd\u003eStandard interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePanel mounting; DIN rail mounting only where permitted by the applicable hardware instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003eUp to 50°C without derating under specified installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m without derating; higher installations require rating checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrake circuit\u003c\/td\u003e\n\u003ctd\u003eIntegrated brake IGBT listed for this model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSelection note:\u003c\/strong\u003e Always size the drive against motor nameplate current, load characteristics, supply conditions, and the manufacturer's derating tables. A matching horsepower rating alone does not establish suitability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControl Capabilities | Match the Drive to the Load\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003cth\u003eTypical purpose\u003c\/th\u003e\n\u003cth\u003eEngineering consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSinusoidal PWM \/ Volts per Hertz\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose speed control\u003c\/td\u003e\n\u003ctd\u003eSuitable for many pumps, fans, and simple conveyor applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensorless Vector Control\u003c\/td\u003e\n\u003ctd\u003eImproved speed and torque response without an encoder\u003c\/td\u003e\n\u003ctd\u003eMotor data and drive tuning influence performance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEconomizer mode\u003c\/td\u003e\n\u003ctd\u003eAdjust motor operation under suitable load conditions\u003c\/td\u003e\n\u003ctd\u003eVerify suitability for the actual motor and operating cycle.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity Vector Control\u003c\/td\u003e\n\u003ctd\u003eApplications requiring more precise speed regulation\u003c\/td\u003e\n\u003ctd\u003eConfirm the required feedback hardware and supported configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent-magnet motor control\u003c\/td\u003e\n\u003ctd\u003eCompatible surface-mount or interior permanent-magnet motors\u003c\/td\u003e\n\u003ctd\u003eCheck motor type, feedback requirements, and supported firmware functions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe achievable speed regulation depends on the selected control method, motor parameters, load, and feedback configuration. Do not apply a single performance figure to every operating mode.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnectivity and Automation Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded EtherNet\/IP:\u003c\/strong\u003e Connects the drive to compatible controllers and industrial networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Level Ring:\u003c\/strong\u003e Supported network topologies can improve communication resilience when the complete network supports the required configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital I\/O:\u003c\/strong\u003e Supports configurable machine commands and status interfaces. Confirm the exact terminal allocation in the manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog references:\u003c\/strong\u003e Compatible analog inputs support suitable speed-reference signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder interface:\u003c\/strong\u003e Verify encoder requirements, supported feedback options, and wiring before selecting a closed-loop application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration software:\u003c\/strong\u003e Use compatible Rockwell Automation tools and device profiles for parameter setup and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not assume DeviceNet, PROFIBUS DP, or dual-port communication functions are included in this exact catalog number. Confirm any required network adapter or accessory separately.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Commissioning Workflow\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the supply.\u003c\/strong\u003e Confirm the available three-phase voltage and protective device ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the motor nameplate.\u003c\/strong\u003e Record rated voltage, current, frequency, power, and speed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect panel conditions.\u003c\/strong\u003e Allow the required clearances and airflow for the selected mounting arrangement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the drive.\u003c\/strong\u003e Follow the official mounting instructions and applicable electrical codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire power and motor terminals.\u003c\/strong\u003e Keep control wiring separated from motor output cables where practical.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnect control signals.\u003c\/strong\u003e Verify digital inputs, analog references, network cables, and grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnter motor data.\u003c\/strong\u003e Set the required motor parameters before performing the prescribed tuning procedure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest at low speed.\u003c\/strong\u003e Confirm rotation direction, acceleration, stopping behavior, and load response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify communications.\u003c\/strong\u003e Check the drive's network address, controller configuration, and command ownership.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eMounting caution:\u003c\/strong\u003e Zero-stacking and horizontal mounting depend on the drive's installation requirements. Horizontal arrangements may require additional cooling measures. Confirm the precise conditions in the current manual.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Fit | Where This Drive Adds Value\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyors:\u003c\/strong\u003e Adjust belt speed to match production flow and transfer timing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps:\u003c\/strong\u003e Regulate flow-related motor speed where the hydraulic system permits variable-speed operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFans and blowers:\u003c\/strong\u003e Match airflow demand while avoiding unnecessary constant-speed operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging machinery:\u003c\/strong\u003e Control compatible feed, indexing, and material-handling motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixers and agitators:\u003c\/strong\u003e Adjust rotational speed for suitable process and load requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine tools and auxiliary drives:\u003c\/strong\u003e Provide programmable speed control for compatible auxiliary motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExisting automation systems:\u003c\/strong\u003e Integrate motor control with supported EtherNet\/IP-based control architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Guide | Identify Faults Before Replacing Hardware\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSymptom\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive does not start\u003c\/td\u003e\n\u003ctd\u003eMissing enable signal, active interlock, incorrect command source, or fault state\u003c\/td\u003e\n\u003ctd\u003eCheck the fault code, input status, command source, and safety circuit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor accelerates poorly\u003c\/td\u003e\n\u003ctd\u003eExcessive load, unsuitable acceleration time, or incorrect motor data\u003c\/td\u003e\n\u003ctd\u003eReview motor parameters, load torque, current limit, and ramp settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent trip\u003c\/td\u003e\n\u003ctd\u003eShort circuit, mechanical binding, rapid acceleration, or motor wiring issue\u003c\/td\u003e\n\u003ctd\u003eIsolate power and inspect the motor circuit before restarting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC bus or undervoltage fault\u003c\/td\u003e\n\u003ctd\u003eSupply dip, unstable incoming power, or an unsuitable supply configuration\u003c\/td\u003e\n\u003ctd\u003eMeasure the supply safely and review the recorded fault conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent network communication\u003c\/td\u003e\n\u003ctd\u003eIncorrect IP settings, cable faults, switch configuration, or network topology issues\u003c\/td\u003e\n\u003ctd\u003eCheck link status, addressing, network diagnostics, and device configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor speed fluctuates\u003c\/td\u003e\n\u003ctd\u003eUnstable reference, incorrect tuning, load variation, or unsuitable control mode\u003c\/td\u003e\n\u003ctd\u003eCompare the speed reference with output frequency and inspect load behavior.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected motor heating\u003c\/td\u003e\n\u003ctd\u003eLow-speed cooling limits, excessive load, incorrect motor data, or poor ventilation\u003c\/td\u003e\n\u003ctd\u003eCheck motor current, cooling arrangements, duty cycle, and parameter settings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A conveyor may trip during startup even when the drive's power rating matches the motor. An engineer should check acceleration time, mechanical binding, motor nameplate data, and the recorded fault code before increasing the drive rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic limitation:\u003c\/strong\u003e Drive fault history and parameter monitoring help narrow down likely causes. They cannot independently prove that a motor, cable, or mechanical component has failed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a drive, engineers should compare the complete catalog number instead of matching power ratings alone. The suffix can determine voltage class, filter configuration, and other hardware characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical insight:\u003c\/strong\u003e If a replacement drive communicates successfully but the machine will not run, verify command ownership, digital enable logic, safety status, and motor parameter values. Network connectivity alone does not confirm a complete control path.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelection guidance:\u003c\/strong\u003e This model suits compatible 480 V-class systems requiring approximately 0.75 kW motor control. Confirm motor current, braking needs, enclosure conditions, and communication requirements before ordering.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFive Professional FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How can I confirm that this drive matches my existing PowerFlex installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the full catalog number, supply voltage, output current, enclosure, filter option, and control wiring. Also review the controller program and communication configuration before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What information should I collect before requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the catalog number, motor nameplate, supply voltage, application type, communication requirements, and quantity. A clear photograph of the drive label helps verify the exact configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: When should I choose a drive with an integral EMC filter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsider the site's electromagnetic compatibility requirements, cable lengths, grounding system, and applicable standards. This catalog configuration specifies no integral EMC filter, so confirm whether additional filtering is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How can I distinguish a drive fault from a mechanical overload?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRecord the fault code and operating conditions first. Then inspect motor current, load movement, acceleration settings, and mechanical resistance using approved isolation and test procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What should I verify before enabling network-based motor control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfirm the IP configuration, controller connection, drive command source, start permissives, safety functions, and fault-reset logic. Test the sequence at low speed before returning the machine to production.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e One Allen-Bradley PowerFlex 525 drive, catalog number \u003cstrong\u003e25B-D2P3N104\u003c\/strong\u003e, subject to the confirmed order configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Cables, external filters, network accessories, and installation hardware require separate confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty under the agreed terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch target:\u003c\/strong\u003e 24–48 hours after order confirmation, subject to stock availability and payment processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, or DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder verification:\u003c\/strong\u003e Confirm catalog number, quantity, delivery address, and required accessories before payment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote | Global PLC Spare HUB\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact Global PLC Spare HUB for pricing, availability, and delivery options for the \u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eAllen-Bradley 25B-D2P3N104\u003c\/span\u003e\u003c\/strong\u003e PowerFlex 525 adjustable frequency drive.\u003c\/p\u003e\n\u003cp\u003eShare your motor specifications and existing drive configuration to help confirm compatibility. Our team can review your requirements before order placement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013822570678,"sku":"25B-D2P3N104","price":143.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/25B-D2P3N104-1.jpg?v=1792044649","url":"https:\/\/www.plcsparehub.com\/products\/25b-d2p3n104-powerflex-525-ac-drive-by-allen-bradley","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}