{"product_id":"2198-c4030-ers-allen-bradley-6-25-kw-kinetix-5300-servo-drive","title":"2198-C4030-ERS Allen-Bradley 6.25 kW Kinetix 5300 Servo Drive","description":"\u003ch3\u003e\u003cstrong\u003eAllen-Bradley 1783-USP8T | Stratix 2100 Industrial Ethernet Switch\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1783-USP8T\u003c\/strong\u003e is an unmanaged Ethernet switch in the Stratix 2100 family. It connects Ethernet-enabled automation devices through eight 10\/100 Mbps copper ports, providing straightforward Layer 2 connectivity for industrial control networks.\u003c\/p\u003e\n\n\u003cp\u003eIts unmanaged architecture suits installations that need basic Ethernet connectivity without configuring VLANs, routing, or advanced switch-management policies. Engineers can use it to connect compatible PLCs, HMIs, engineering workstations, and other Ethernet devices within an appropriately designed control network.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSelection priority:\u003c\/strong\u003e Confirm the required port count, network speed, power input, mounting arrangement, environmental conditions, and network architecture before replacing an existing switch or specifying a new installation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e01 | Hardware Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003eStratix 2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1783-USP8T\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eUnmanaged industrial Ethernet switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching application\u003c\/td\u003e\n\u003ctd\u003eLayer 2 Ethernet switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet ports\u003c\/td\u003e\n\u003ctd\u003e8 copper Fast Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort connector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, 10\/100Base-TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40 to +75°C, according to the manufacturer's product listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply classification\u003c\/td\u003e\n\u003ctd\u003eSELV\/PELV; verify the permitted input voltage and wiring against the device label and applicable manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional predecessor\u003c\/td\u003e\n\u003ctd\u003e1783-US8T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cem\u003eTechnical note: IP30 provides protection against access to hazardous parts and solid objects of the specified size under the applicable rating conditions. It does not indicate protection against water ingress. Install the switch in a suitable enclosure when the surrounding environment requires additional protection.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e02 | Eight Ports, One Practical Network Layer\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe eight copper Ethernet interfaces allow multiple devices to share a local network segment. Each connected device still requires a compatible Ethernet interface, appropriate addressing, and a valid communication configuration.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC connectivity:\u003c\/strong\u003e Connect compatible Ethernet-enabled controllers to the local automation network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHMI communication:\u003c\/strong\u003e Provide a wired Ethernet path between operator terminals and supported controllers or data sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering access:\u003c\/strong\u003e Connect authorized engineering workstations for controller programming, troubleshooting, and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrive and equipment integration:\u003c\/strong\u003e Connect compatible Ethernet-enabled drives, machine controllers, or other automation devices when their communication requirements match the network design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocal device aggregation:\u003c\/strong\u003e Consolidate multiple copper Ethernet connections within a machine or control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFast Ethernet supports link speeds up to 100 Mbps per port. Actual application performance depends on traffic, connected-device capabilities, protocol behavior, cable quality, and the wider network topology.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e03 | Application Fit: Where to Use This Switch\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation environment\u003c\/th\u003e\n\u003cth\u003eTypical role\u003c\/th\u003e\n\u003cth\u003eEngineering review\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLC control cabinets\u003c\/td\u003e\n\u003ctd\u003eLocal Ethernet connections between controllers and supported devices\u003c\/td\u003e\n\u003ctd\u003eCheck controller communication requirements and cabinet power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging and assembly machines\u003c\/td\u003e\n\u003ctd\u003eConnecting HMIs, controllers, and compatible machine components\u003c\/td\u003e\n\u003ctd\u003eEvaluate traffic demand and required network recovery behavior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConveyor and material-handling systems\u003c\/td\u003e\n\u003ctd\u003eProviding local wired connectivity for automation equipment\u003c\/td\u003e\n\u003ctd\u003eReview cable routing, electrical noise exposure, and network layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial skids\u003c\/td\u003e\n\u003ctd\u003eAggregating Ethernet links for process or auxiliary equipment\u003c\/td\u003e\n\u003ctd\u003eVerify temperature, enclosure protection, and supply requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMachine retrofit projects\u003c\/td\u003e\n\u003ctd\u003eReplacing an older compatible switch with a current functional alternative\u003c\/td\u003e\n\u003ctd\u003eCheck port count, power wiring, mounting, and communication requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance and test panels\u003c\/td\u003e\n\u003ctd\u003eConnecting supported Ethernet devices during commissioning or servicing\u003c\/td\u003e\n\u003ctd\u003eControl network access and avoid unintended connections to production networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant limitation:\u003c\/strong\u003e This is an unmanaged switch. Do not select it when the application specifically requires configurable VLANs, managed traffic prioritization, advanced port diagnostics, redundant network protocols, or other managed-switch functions unless the overall design provides those capabilities elsewhere.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e04 | Network Layout and Installation Checks\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eCorrect installation starts with the intended network topology. Before mounting the switch, identify which devices require direct Ethernet connections and whether the network needs segmentation, redundancy, or managed traffic control.\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCount the connections:\u003c\/strong\u003e Allow sufficient ports for current devices and planned expansion. Eight physical ports do not guarantee that every topology or future expansion requirement will fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm link compatibility:\u003c\/strong\u003e Check the Ethernet speed and interface requirements of each connected device. Use suitable industrial Ethernet cabling and compatible RJ45 connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the power input:\u003c\/strong\u003e Read the switch nameplate and the applicable installation manual. Do not assume that every AC or DC supply listed by a third-party seller applies to every hardware version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan the DIN rail position:\u003c\/strong\u003e Allow access to connectors, wiring, status indicators, and ventilation requirements specified by the manufacturer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate communication and power wiring appropriately:\u003c\/strong\u003e Follow site wiring practices to reduce electrical interference and prevent cable damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLabel each port:\u003c\/strong\u003e Record the connected device and cable destination. Clear labels reduce troubleshooting time when multiple devices lose communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidate the network:\u003c\/strong\u003e Check link indicators, cable seating, device addressing, and application-level communication after energizing the installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003e05 | Field Diagnostics: Trace the Fault from Link to Application\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eAn unmanaged switch offers simpler diagnostics than a managed switch. Engineers should use the available status indicators and systematic cable and device checks instead of expecting detailed network statistics or a configurable management interface.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved symptom\u003c\/th\u003e\n\u003cth\u003eLikely areas to investigate\u003c\/th\u003e\n\u003cth\u003eRecommended checks\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo device communication after startup\u003c\/td\u003e\n\u003ctd\u003ePower supply, loose connections, incorrect cabling, or a device that has not started\u003c\/td\u003e\n\u003ctd\u003eVerify the supply against the nameplate, inspect wiring, and check each device's network interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne port has no link indication\u003c\/td\u003e\n\u003ctd\u003eDamaged cable, poor connector termination, disabled device interface, or a remote device fault\u003c\/td\u003e\n\u003ctd\u003eCheck the cable and connector, confirm the remote device is powered, and test with a known-good cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLink is present but PLC communication fails\u003c\/td\u003e\n\u003ctd\u003eIP address conflict, subnet mismatch, incorrect controller configuration, or an application-level issue\u003c\/td\u003e\n\u003ctd\u003eCheck addressing, controller configuration, device availability, and the relevant communication settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent communication on one connection\u003c\/td\u003e\n\u003ctd\u003eLoose RJ45 connector, cable damage, electromagnetic interference, or an unstable remote device\u003c\/td\u003e\n\u003ctd\u003eInspect cable routing and connectors; monitor the link during operation and substitute a verified cable if safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral devices lose communication together\u003c\/td\u003e\n\u003ctd\u003eSwitch power interruption, a common uplink or cable issue, or a broader network fault\u003c\/td\u003e\n\u003ctd\u003eCheck power stability, common connections, network topology, and the status of upstream equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication slows during machine operation\u003c\/td\u003e\n\u003ctd\u003eHigh traffic demand, broadcast activity, device performance, or an application bottleneck\u003c\/td\u003e\n\u003ctd\u003eReview connected devices and traffic sources; use suitable diagnostic tools elsewhere in the network if detailed statistics are required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eDiagnostic boundary:\u003c\/strong\u003e Link status indicates a physical Ethernet connection, not successful PLC messaging. If the link is active but the application fails, continue with IP configuration, device diagnostics, controller status, and protocol-specific checks.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e06 | Replacement Guidance: 1783-US8T to 1783-USP8T\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eRockwell Automation identifies \u003cstrong\u003e1783-USP8T\u003c\/strong\u003e as the functional replacement for the discontinued \u003cstrong\u003e1783-US8T\u003c\/strong\u003e. The newer catalog number belongs to the Stratix 2100 family and provides eight 10\/100 Mbps copper Ethernet ports.\u003c\/p\u003e\n\n\u003cp\u003eBefore ordering a replacement, confirm the following points:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eVerify that the existing unit is actually catalog number 1783-US8T and not another Stratix model.\u003c\/li\u003e\n\u003cli\u003eCompare the existing supply wiring with the replacement's permitted input requirements.\u003c\/li\u003e\n\u003cli\u003eConfirm DIN rail fit, available cabinet space, connector access, and cable routing.\u003c\/li\u003e\n\u003cli\u003eCheck whether the current network depends on managed-switch functions or a special topology that an unmanaged replacement cannot provide.\u003c\/li\u003e\n\u003cli\u003eValidate device communication after installation, including controller access and any HMI or drive connections that depend on the switch.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eA functional replacement designation is useful for selection, but it does not remove the need to verify the actual cabinet wiring and application requirements.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e07 | Global PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eFor maintenance engineers, the primary benefit of the \u003cstrong\u003e1783-USP8T\u003c\/strong\u003e is straightforward copper Ethernet connectivity without the configuration workload associated with managed switches. This can simplify local network installation when the application does not require advanced switching features.\u003c\/p\u003e\n\n\u003cp\u003eFor a retrofit, do not diagnose every communication failure as a switch defect. A missing link may originate from the cable, remote interface, or power supply, while an active link with failed controller communication may indicate addressing or application configuration issues.\u003c\/p\u003e\n\n\u003cp\u003eWhen replacing a legacy unit, record the original catalog number, power connections, port assignments, and connected-device list before removal. This record helps technicians restore the network methodically and reduces the risk of overlooking a critical connection during downtime.\u003c\/p\u003e\n\n\u003cp\u003eGlobal PLC Spare HUB recommends confirming the exact model, hardware label, supply requirements, and required delivery schedule before purchase. For applications that need advanced diagnostics or network segmentation, evaluate whether a managed switch better matches the design.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e08 | Warranty, Packaging, and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Allen-Bradley Stratix 2100 unmanaged Ethernet switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 1783-USP8T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty, subject to the written warranty terms and coverage conditions provided with the order\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e Confirm current stock status and dispatch timing when requesting a quotation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Supplied according to the confirmed order and quotation; confirm any specific packaging requirements before purchase\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCheck the quotation for included accessories and documentation. Ethernet cables, power supplies, DIN rail accessories, and other installation materials should not be assumed to be included unless explicitly listed.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003e09 | Frequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: Can I use this switch to connect a PLC, HMI, and several Ethernet-enabled drives?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePotentially, provided each device supports compatible Ethernet connectivity and the total port count meets the installation requirement. Check whether the drives and controller require specific network functions, deterministic performance, or managed traffic controls. The switch provides basic connectivity but does not replace application-level configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: If the port indicator is on, does that confirm the PLC network is working correctly?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eNo. A link indicator generally confirms a physical Ethernet link, not successful communication between applications. Check device IP addresses, subnet settings, controller configuration, and the relevant communication status. If only one device fails, compare its configuration and cable with a known-working connection.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What should I check before choosing between a five-port and an eight-port switch?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eCount all required connections, including PLCs, HMIs, drives, engineering access, and any uplink to another network device. Reserve capacity for foreseeable expansion where practical. Verify the exact catalog number because Stratix 2100 includes models with different port counts and interface types.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ4: Is IP30 sufficient for a dusty or washdown production area?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eIP30 does not provide water-ingress protection and offers limited protection against solid objects. For dusty, wet, or washdown environments, assess the cabinet's required ingress rating and the complete installation conditions. The enclosure, cable entries, cooling arrangement, and maintenance practices must collectively suit the environment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ5: What details should I send when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eProvide the full catalog number, quantity, photos of the nameplate, required delivery destination, and target arrival date. If replacing an installed switch, include its supply wiring details and a list of connected devices. Ask the supplier to confirm availability, warranty terms, and the shipping service before ordering.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eNeed the \u003cstrong\u003eAllen-Bradley 1783-USP8T Stratix 2100 unmanaged Ethernet switch\u003c\/strong\u003e for a new installation or a network replacement? Send your required quantity, delivery destination, and existing model details to request a quotation and confirm product compatibility, availability, and shipping options.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67644147531958,"sku":"2198-C4030-ERS","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1783-USP8T-1_a474b00d-b95f-49e2-ad47-76e1e4001518.jpg?v=1792045748","url":"https:\/\/www.plcsparehub.com\/products\/2198-c4030-ers-allen-bradley-6-25-kw-kinetix-5300-servo-drive","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}