{"product_id":"2198-c4020-ers-allen-bradley-kinetix-5300-servo-drive-3-9-kw-motion-control","title":"2198-C4020-ERS Allen-Bradley Kinetix 5300 Servo Drive | 3.9 kW Motion Control","description":"\n\u003ch3\u003e\u003cb\u003eAllen-Bradley 2198-C4020-ERS — Kinetix 5300 Single-Axis Servo Drive\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cb\u003e\u003cspan style=\"color: #1673B1;\"\u003e2198-C4020-ERS\u003c\/span\u003e\u003c\/b\u003e is a single-axis servo drive in the Allen-Bradley Kinetix 5300 family. It provides coordinated motor control through an EtherNet\/IP interface and supports linear or ring network topologies. The supplied specifications identify a 380–480 V AC, three-phase input and 3.9 kW continuous output rating.\u003c\/p\u003e\n\n\u003cp\u003eFor machine builders and maintenance engineers, the drive’s key selection points are its voltage class, continuous and peak current, motor feedback requirements, network layout, digital I\/O and Safe Torque Off (STO) interface. Confirm that the selected motor, feedback device and safety architecture match the installed system before commissioning.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eDrive Profile — Ratings at a Glance\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePart number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2198-C4020-ERS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct family\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eKinetix 5300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDrive type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-axis servo drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e380–480 V AC, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInput frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eContinuous output power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eContinuous current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3 A RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePeak current\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10.3 A peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNetwork\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo RJ45 EtherNet\/IP ports; linear or ring topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eEncoder power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC and 9 V DC supply options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDigital inputs\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFour 24 V DC sinking inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSafety interface\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel Safe Torque Off (STO) input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eBrake control\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC brake output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eShort-circuit rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kA, as supplied in the product data; verify the required upstream protection and installation conditions in the manufacturer’s documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5.00 lb (2.27 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUPC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e191326677646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cb\u003eControl Architecture — How the Drive Fits into a Machine\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMotion command:\u003c\/b\u003e The controller communicates with the drive over EtherNet\/IP. The two RJ45 ports support the stated linear or ring network arrangements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMotor feedback:\u003c\/b\u003e The drive provides 5 V DC and 9 V DC encoder power options. Confirm the specific motor and feedback-device compatibility, connector pinout and feedback type using the drive and motor manuals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMachine I\/O:\u003c\/b\u003e Four 24 V DC sinking inputs support compatible control signals. Check input logic and wiring requirements before connecting sensors or machine signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBrake interface:\u003c\/b\u003e The 24 V DC brake output can be used with a compatible motor brake circuit. Verify the brake’s electrical rating and required external components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSafety circuit:\u003c\/b\u003e The dual-channel STO input is intended for integration into an appropriate safety control system. STO removes torque-producing capability; it does not itself provide electrical isolation or mechanically stop a moving load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eWhere It Can Be Used\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePackaging and converting machinery:\u003c\/b\u003e Axis control for indexing, feeding, sealing, cutting and coordinated machine movement, where the motor and load fall within the drive’s ratings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaterial handling:\u003c\/b\u003e Servo-driven positioning and transfer mechanisms in compatible conveyor, pick-and-place or handling equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAssembly and automation stations:\u003c\/b\u003e Single-axis motion in fixtures, actuators and automated production equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMachine tools and process equipment:\u003c\/b\u003e Motion applications requiring controlled positioning or speed, subject to motor, load and duty-cycle sizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEtherNet\/IP machine networks:\u003c\/b\u003e Systems using a compatible controller and a supported network topology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese are application categories, not confirmation of a specific machine’s compatibility. Final selection depends on motor voltage and current, torque and speed requirements, inertia, duty cycle, feedback device, regenerative-energy handling, controller support and the machine’s safety design.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Checks Before Installation\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cb\u003eVerify the supply:\u003c\/b\u003e Confirm that the incoming three-phase supply is within the specified 380–480 V AC range and that the installation meets the manufacturer’s grounding and protection requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSize the motor and axis:\u003c\/b\u003e Compare the motor’s continuous and peak current demands with the drive’s 7.3 A RMS continuous and 10.3 A peak ratings. Check acceleration, deceleration and thermal duty—not just nominal motor power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfirm feedback:\u003c\/b\u003e Match the motor feedback technology and required encoder supply to the drive’s supported configuration. Do not assume that every 5 V or 9 V encoder is compatible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePlan the network:\u003c\/b\u003e Confirm controller compatibility, IP addressing, topology and the required EtherNet\/IP configuration. Use the prescribed cabling and network practices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eValidate safety:\u003c\/b\u003e Design and validate the dual-channel STO circuit according to the machine risk assessment and applicable safety requirements. Do not treat STO as a lockout or energy-isolation device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCheck brake behavior:\u003c\/b\u003e Verify the motor brake’s voltage, current, timing and control sequence. A brake output alone does not establish that a load will be safely held under every fault condition.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cb\u003eDiagnostics and Troubleshooting Approach\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eUse the drive’s status and fault information available through the applicable Rockwell Automation tools and manuals. The specifications provided here do not identify individual fault codes, so the following are diagnostic checks rather than a fault-code list.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDrive will not enable:\u003c\/b\u003e Check supply conditions, controller-to-drive communication, configuration, active faults and the state of the STO channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEtherNet\/IP connection issue:\u003c\/b\u003e Inspect network cabling, port connections, device addressing, controller configuration and network topology. Check whether the intended linear or ring architecture is supported and configured correctly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMotor feedback fault:\u003c\/b\u003e Verify feedback-device compatibility, wiring, connector seating and encoder supply requirements. Inspect for cable damage or electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAxis trips during acceleration:\u003c\/b\u003e Compare commanded motion and load demand with current and torque limits. Review acceleration, inertia mismatch, mechanical binding and the application duty cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUnexpected stopping or torque removal:\u003c\/b\u003e Check the STO circuit and safety-controller status. Determine whether the stop resulted from a safety command, drive fault or control-system event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBrake-related movement:\u003c\/b\u003e Verify brake wiring and sequencing, mechanical brake condition, and whether the brake is rated to hold the load. Follow the manufacturer’s procedure for safe testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eFor a replacement or expansion project, treat \u003cb\u003e2198-C4020-ERS\u003c\/b\u003e as a complete drive configuration, not simply a 3.9 kW rating. The most important pre-order checks are the actual motor\/feedback pairing, controller and EtherNet\/IP setup, supply voltage, brake requirements and STO circuit design.\u003c\/p\u003e\n\n\u003cp\u003eIn practical commissioning, record the existing axis parameters and fault history before swapping hardware. After installation, verify network connection, motor feedback, direction of travel, brake operation and the safety response under an approved test procedure. Begin with a controlled, low-risk motion test before returning the machine to production.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eWarranty and Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty:\u003c\/b\u003e 12-month warranty, subject to applicable supplier terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eShipping options:\u003c\/b\u003e FedEx, UPS and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch:\u003c\/b\u003e Timing is confirmed after stock and order verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompatibility support:\u003c\/b\u003e Share the complete drive part number, motor model and controller\/network details when requesting a quotation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cb\u003e1. How do I determine whether this drive has enough capacity for my servo motor?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the motor’s rated and peak current with the drive ratings, then evaluate torque demand across the complete motion profile. Include acceleration, deceleration, load inertia, duty cycle and thermal limits. A motor’s kW value alone is not sufficient for sizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e2. Can I replace another Kinetix drive with this model without changing the machine configuration?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eDo not assume a drop-in replacement based only on the Kinetix family. Confirm the exact drive catalog number, motor and feedback compatibility, power wiring, controller support, network configuration, mounting and safety connections. Review the applicable migration or replacement documentation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e3. What should I check if the drive communicates over EtherNet\/IP but the axis does not move?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eCheck the axis enable sequence, active drive faults, STO channel status, motor feedback, motion configuration and commanded limits. A healthy network connection does not prove that the axis is enabled or that its safety conditions are satisfied.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e4. Is the dual-channel STO input sufficient to meet the machine’s safety requirements?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNot by itself. The required safety performance depends on the complete safety function, including the safety controller, wiring, risk assessment, validation and applicable standards. STO prevents torque production but does not provide electrical isolation or guarantee that a suspended or moving load is mechanically secured.\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003e5. What details should I send when requesting a quotation for a spare drive?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the full catalog number, motor nameplate data, feedback type, controller model, supply voltage, network arrangement and any brake or safety-interface requirements. If replacing an installed drive, include its application and fault symptoms to help assess whether the same configuration is appropriate.\u003c\/p\u003e\n","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67716287037622,"sku":"2198-C4020-ERS","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/2198-C4020-ERS-3.jpg?v=1792640567","url":"https:\/\/www.plcsparehub.com\/products\/2198-c4020-ers-allen-bradley-kinetix-5300-servo-drive-3-9-kw-motion-control","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}