{"product_id":"200355-12-00-00-bently-nevada-200350-accelerometer","title":"200355-12-00-00 Bently Nevada 200350 Accelerometer","description":" \u003ch3\u003e\u003cstrong\u003eBently Nevada 200355-12-00-00 Accelerometer – Dynamic Vibration Measurement for Industrial Machinery\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 200355-12-00-00\u003c\/strong\u003e is a piezoelectric accelerometer from the \u003cstrong\u003e200350 Series\u003c\/strong\u003e, designed to measure machinery vibration across a broad frequency range. Its ceramic sensing element uses a shear-mode measurement geometry to convert mechanical acceleration into an electrical output for condition monitoring and vibration analysis systems.\u003c\/p\u003e\n\n\u003cp\u003eWith a nominal sensitivity of \u003cstrong\u003e100 mV\/g ±20%\u003c\/strong\u003e, a measurement range of \u003cstrong\u003e±50 g\u003c\/strong\u003e, and a frequency response of \u003cstrong\u003e0.5 Hz to 10 kHz\u003c\/strong\u003e (±3 dB), this sensor supports vibration measurement on industrial rotating equipment. Its stainless steel housing, welded hermetic sealing, and IP68 enclosure rating support installation in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Configuration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe model number identifies the sensor family, mounting configuration, sensitivity tolerance, and approval option.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e200355\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct model\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 200350 Series accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting option\u003c\/td\u003e\n\u003ctd\u003eM8 × 1.25 adhesive stud mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensitivity tolerance\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency approval\u003c\/td\u003e\n\u003ctd\u003eNo agency approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration note:\u003c\/strong\u003e The supplied specification also lists a 1\/4-28 female mounting thread. Confirm the required mounting stud or adapter arrangement against the sensor drawing and installed mounting hardware before ordering a replacement.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMeasurement Performance and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003ePiezoelectric accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing element\u003c\/td\u003e\n\u003ctd\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing geometry\u003c\/td\u003e\n\u003ctd\u003eShear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g ±20% (10.2 mV\/m\/s² ±20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e30–600,000 cpm (0.5–10,000 Hz), ±3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e±50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse sensitivity\u003c\/td\u003e\n\u003ctd\u003e≤7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude linearity\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounted resonant frequency\u003c\/td\u003e\n\u003ctd\u003e1,500 kcpm (25 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroadband electrical noise\u003c\/td\u003e\n\u003ctd\u003e350 μg (3,434 μm\/s²), 1–10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput bias voltage\u003c\/td\u003e\n\u003ctd\u003e8–12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge time constant\u003c\/td\u003e\n\u003ctd\u003e≥0.3 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling time\u003c\/td\u003e\n\u003ctd\u003e2.0 sec to within 1% of bias\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003ePower Requirements and Electrical Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe accelerometer uses constant-current excitation and provides a voltage output proportional to the measured acceleration. The receiving instrument must supply compatible sensor excitation and support the accelerometer's output bias and impedance characteristics.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcitation voltage:\u003c\/strong\u003e 18–28 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant-current excitation:\u003c\/strong\u003e 2–20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput bias voltage:\u003c\/strong\u003e 8–12 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput impedance:\u003c\/strong\u003e Less than 150 ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical isolation at case:\u003c\/strong\u003e Greater than 10⁸ ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical connector:\u003c\/strong\u003e 2-pin MIL-C-5015\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector position:\u003c\/strong\u003e Top\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWhen integrating the sensor with a vibration monitor or data acquisition system, check the input's constant-current supply, voltage compliance, signal conditioning, and connector pin assignment. A mismatch in excitation or input configuration can produce an incorrect bias level, unstable readings, or loss of the vibration signal.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eMechanical Design and Environmental Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical \/ Environmental Parameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eWelded hermetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting thread\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting stud option\u003c\/td\u003e\n\u003ctd\u003eM8 × 1.25 adhesive stud mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum mounting torque\u003c\/td\u003e\n\u003ctd\u003e2–5 ft-lb (2.7–6.8 N·m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHex size\u003c\/td\u003e\n\u003ctd\u003e11\/16 in (approximately 1.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e1.65 in (4.24 cm), as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.051 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−65°F to +250°F (−54°C to +121°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock survivability\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e100%, condensing, non-submerged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing origin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A., as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Considerations for Reliable Vibration Data\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eAccelerometer mounting quality directly affects the usable frequency response and repeatability of vibration measurements. Before installation, inspect the mounting surface for contamination, paint, corrosion, and uneven contact. Prepare the mounting location according to the applicable installation procedure and confirm that the selected stud or adhesive arrangement matches the machine surface and sensor interface.\u003c\/p\u003e\n\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the mounting interface:\u003c\/strong\u003e Check the M8 × 1.25 adhesive stud option and the listed 1\/4-28 female thread against the installation drawing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the contact surface:\u003c\/strong\u003e Use a clean, flat mounting location to reduce measurement errors caused by poor mechanical coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl mounting torque:\u003c\/strong\u003e Follow the applicable mounting instructions and do not exceed the specified torque limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify electrical compatibility:\u003c\/strong\u003e Confirm constant-current excitation, voltage range, connector wiring, and input impedance before energizing the measurement circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the output after installation:\u003c\/strong\u003e Allow the specified settling time and verify the bias voltage before evaluating vibration amplitude or frequency data.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTypical Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe broad frequency response and acceleration measurement range make the \u003cstrong\u003e200355-12-00-00\u003c\/strong\u003e suitable for vibration monitoring tasks where machinery condition must be evaluated through acceleration signals.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eVibration monitoring of pumps, motors, and compressors\u003c\/li\u003e\n\u003cli\u003eCondition assessment of rotating machinery and mechanical assemblies\u003c\/li\u003e\n\u003cli\u003eHigh-frequency vibration measurement for bearing and gear-related analysis\u003c\/li\u003e\n\u003cli\u003eIndustrial equipment vibration trending and diagnostic data acquisition\u003c\/li\u003e\n\u003cli\u003eMachinery maintenance programs requiring repeatable acceleration measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eReplacement Selection and Technical Verification\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eWhen replacing an installed accelerometer, do not select a sensor by sensitivity alone. Confirm the mounting configuration, frequency response, measurement range, excitation requirements, connector type, and approval status. The \u003cstrong\u003e200355-12-00-00\u003c\/strong\u003e specification lists no agency approvals, so it should not be treated as an approved sensor for a hazardous-area installation unless the complete installation design provides the required protection through other applicable measures.\u003c\/p\u003e\n\n\u003cp\u003eFor retrofit work, compare the existing sensor's mounting arrangement and signal-conditioning requirements with the replacement specification. Also verify whether the receiving monitor expects an acceleration signal with a 100 mV\/g nominal sensitivity and whether its input supports the specified bias voltage and constant-current excitation.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eWarranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping methods:\u003c\/strong\u003e FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct support:\u003c\/strong\u003e Model and configuration verification can help reduce ordering errors during replacement and maintenance planning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e1. What should be checked if the accelerometer output has a normal bias voltage but shows unusually low vibration amplitude?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst inspect the mechanical coupling between the sensor and machine surface. A loose stud, contaminated mounting face, or unsuitable mounting adapter can reduce high-frequency response. Then verify the monitor's sensitivity setting and signal scaling. A nominal 100 mV\/g sensor configured with an incorrect sensitivity value can produce misleading engineering-unit readings even when the electrical signal is present.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Can this accelerometer be installed in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied configuration specifies agency approval option 00, meaning no agency approvals. Do not assume that the IP68 enclosure rating provides hazardous-area certification. Review the site classification, applicable electrical installation requirements, and equipment approval documentation before selecting this model for a classified location.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. How does mounting stiffness affect the measurement result?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMounting stiffness influences the mechanical transfer of vibration from the machine to the sensing element. A rigid, clean, correctly installed mounting interface generally provides better high-frequency response than a loose or flexible arrangement. For bearing and gear diagnostics, mounting location and attachment method should remain consistent when comparing vibration trends over time.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e4. What is the practical significance of the 25 kHz mounted resonant frequency?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe mounted resonant frequency identifies a mechanical resonance characteristic of the sensor under its specified mounting condition. It is not the recommended upper measurement frequency. For this model, the stated measurement frequency range is 0.5 Hz to 10 kHz at ±3 dB. Engineers should use that range when evaluating the suitability of the sensor for a measurement task.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e5. What information should be provided when requesting a replacement quotation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvide the complete model number, \u003cstrong\u003e200355-12-00-00\u003c\/strong\u003e, together with the existing sensor's mounting arrangement, connector details, monitor input type, and installation environment. If the application requires hazardous-area approval, state the required certification separately. These details help verify mechanical and electrical compatibility before procurement.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eProduct Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 200355-12-00-00\u003c\/strong\u003e is a 200350 Series ceramic shear-mode accelerometer with 100 mV\/g nominal sensitivity, a ±50 g measurement range, and a 0.5 Hz to 10 kHz frequency response. Its stainless steel hermetically sealed housing and IP68 rating support demanding machinery monitoring environments. Verify the mounting interface and electrical requirements against the installed system before selecting it as a replacement.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68028050833590,"sku":"200355-12-00-00","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently200350200355_12_44fc30e0-70cc-4aa1-ad86-27be7363929d.jpg?v=1794290257","url":"https:\/\/www.plcsparehub.com\/products\/200355-12-00-00-bently-nevada-200350-accelerometer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}