{"product_id":"200350-02-00-01-bently-nevada-accelerometer-case-mounted","title":"200350-02-00-01 Bently Nevada Accelerometer | Case Mounted","description":"\u003ch3\u003e\u003cstrong\u003eBently Nevada \u003cspan style=\"color: #0056b3;\"\u003e200350-02-00-01\u003c\/span\u003e Technical Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e200350-02-00-01\u003c\/span\u003e\u003c\/strong\u003e is an industrial-grade, case-mounted accelerometer designed for continuous vibration monitoring. It delivers high-accuracy dynamic feedback on high-speed rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis model features a shear-geometry ceramic sensing element that provides a nominal sensitivity of 100 mV\/g. It delivers stable performance over a wide frequency spectrum from 0.5 Hz to 10,000 Hz. The electrical circuit is housed in a welded, hermetically sealed stainless steel enclosure carrying an IP68 rating.\u003c\/p\u003e\n\u003cp\u003eThe 2-pin MIL-C-5015 top-exit connection provides a robust industrial interface. This model includes a 1\/4-28 to M8 stainless steel mounting stud and carries global hazardous area certifications, including CSA, ATEX, and IECEx approvals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e200350-02-00-01\u003c\/span\u003e\u003c\/strong\u003e is a standard choice for balanced, broad-spectrum machinery monitoring. Unlike high-sensitivity low-frequency models, this 100 mV\/g sensor balances sensitivity with a wide 50g dynamic range.\u003c\/p\u003e\n\u003cp\u003eThe shear crystal geometry isolates the sensor from thermal transients and base strain forces, which often cause false readings in compression-style accelerometers. The physical build is exceptionally compact, and its lightweight 51-gram design prevents mass-loading effects on smaller machinery casings.\u003c\/p\u003e\n\u003cp\u003eWith its pre-approved hazardous area certifications, this model is highly versatile for complex processing zones. It provides reliable operation in wet, condensing, or corrosive environments where standard sensors fail.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown (Part Number Structural Tree)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ordering code configuration for the Bently Nevada \u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e200350-02-00-01\u003c\/span\u003e\u003c\/strong\u003e accelerometer is structured below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e200350\u003c\/strong\u003e — Case Mounted Industrial Accelerometer Base Model\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02 [This Model]\u003c\/strong\u003e — Mounting Stud Option: 1\/4-28 UNF to M8 x 1.25 stainless steel adapter stud\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00 [This Model]\u003c\/strong\u003e — Sensitivity Tolerance Option: Standard 100 mV\/g ± 20% calibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01 [This Model]\u003c\/strong\u003e — Multi-Agency Approval Option: CSA, ATEX, and IECEx hazardous area certifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical \u0026amp; Structural Components:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Shell:\u003c\/strong\u003e Fully welded, hermetically sealed structural stainless steel (IP68 rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Element:\u003c\/strong\u003e Piezoelectric ceramic crystal arranged in a shear-mode geometry\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e Standard top-exit, 2-pin MIL-C-5015 style receptacle\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTarget Equipment \u0026amp; Plant Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eIndustrial Gas Turbines:\u003c\/strong\u003e Monitoring high-frequency rotor casing vibration and structural resonance zones.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eHigh-Speed Centrifugal Compressors:\u003c\/strong\u003e Tracking casing acceleration and blade-pass frequency harmonics.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eProcess Water Pumps:\u003c\/strong\u003e Capturing early bearing wear and impellor cavitation profiles.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eForced Draft Fans:\u003c\/strong\u003e Detecting shaft misalignment and structural looseness on primary air loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Capabilities \u0026amp; Signal Integrity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eBroad Frequency Capture:\u003c\/strong\u003e Monitors high-speed machinery states across a wide range of 30 to 600,000 cpm (0.5 to 10,000 Hz).\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eHigh-Impact Resistance:\u003c\/strong\u003e Shock survivability rating of 5,000 g peak protects the sensor during sudden mechanical events.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCase Isolation Protection:\u003c\/strong\u003e High electrical isolation (greater than 10^8 ohms) prevents ground loop noise from corrupting the dynamic signal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications Table\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-bottom: 2px solid #dee2e6;\"\u003eSpecification Category\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-bottom: 2px solid #dee2e6;\"\u003eTechnical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eFull Part Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #0056b3;\"\u003e200350-02-00-01\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eNominal Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e100 mV\/g ± 20% (10.2 mV\/m\/s² ± 20% at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eFrequency Response\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e0.5 Hz to 10,000 Hz (30 cpm to 600,000 cpm) ± 3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eMounted Resonant Frequency\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e25 kHz (1,500 kcpm) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eConstant Current Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e2 mA to 20 mA excitation limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eBias Output Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e8 Vdc to 12 Vdc nominal reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003eIP68 (welded hermetic seal, 100% relative humidity, condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eThermal Limits\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e-54°C to +121°C (-65°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: bold; border-bottom: 1px solid #dee2e6;\"\u003eNet Product Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border-bottom: 1px solid #dee2e6;\"\u003e51 grams (0.051 kg) excluding adapter stud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal Logistics, Delivery \u0026amp; Warranty Terms\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eExpress Carriers:\u003c\/strong\u003e Global dispatch via priority DHL, FedEx, and UPS loops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eHandling Time:\u003c\/strong\u003e Orders are packaged and shipped within 24 to 48 hours of verification.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eWarranty Protection:\u003c\/strong\u003e Includes a full 12-month replacement warranty from Global PLC Spare HUB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eStrategic Procurement \u0026amp; Selection Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eThread Verification:\u003c\/strong\u003e The \u003cstrong\u003e-02\u003c\/strong\u003e suffix indicates an M8 x 1.25 metric adapter stud is included. If your machine casing uses a standard imperial 1\/4-28 tapped hole, use a standard 1\/4-28 double-ended stud instead.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eCable Grounding Strategy:\u003c\/strong\u003e Use shielded, twisted-pair cabling. To prevent ground loop noise from corrupting your data, ground the shield only at the monitor end, not at the sensor end.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 5px;\"\u003e\n\u003cstrong\u003eTorque Limit Warnings:\u003c\/strong\u003e Tighten the sensor to between 2 and 5 ft-lb (2.7 to 6.8 N-m). Under-torquing reduces high-frequency response, while over-torquing can damage the mounting base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Frequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the \"Shear\" sensing geometry in the 200350 accelerometer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The shear design subjects the ceramic crystal to parallel shear forces rather than compression forces. This design isolates the sensor from base strain and thermal changes, preventing false low-frequency signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is a settling time of 2.0 seconds required after power-up?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 2.0-second window allows the internal amplifier circuit to charge its coupling capacitor and stabilize its 8 to 12 Vdc bias voltage before outputting valid dynamic signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What indicates that the 200350-02-00-01 has suffered internal damage from physical over-range or shock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the DC bias voltage at the monitoring system. If the bias voltage drifts outside the specified 8 to 12 Vdc range under static conditions, the internal amplifier or ceramic crystal is likely damaged.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this IP68-rated accelerometer be permanently submerged in a water or oil reservoir?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. While the welded stainless steel casing is rated IP68 and handles high humidity and condensing environment, it is designed for non-submerged applications. Permanent submersion will eventually degrade the connector interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the excitation current level (2 to 20 mA) affect the maximum cable run?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Higher excitation currents are needed to drive long cable runs. For runs over 100 feet, increase the excitation current toward the 20 mA limit to overcome cable capacitance and prevent high-frequency signal loss.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/200350.png?v=1784279436\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45267542311094,"sku":"200350-02-00-01","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently200350200355_12.jpg?v=1784279513","url":"https:\/\/www.plcsparehub.com\/products\/200350-02-00-01-bently-nevada-accelerometer-case-mounted","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}