{"product_id":"200152-04-10-bently-nevada-standard-interface-cable-for-vibration-systems","title":"200152-04-10 Bently Nevada Standard Interface Cable for Vibration Systems","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview | Bently Nevada 200152-04-10\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eBently Nevada 200152-04-10\u003c\/span\u003e\u003c\/strong\u003e is an accelerometer interface cable designed to connect compatible accelerometers with vibration monitoring equipment. Its four-conductor construction, braided shield, and molded connectors support signal transmission in industrial monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines a \u003cstrong\u003e4.0-meter cable\u003c\/strong\u003e with an enhanced coupling nut on the accelerometer end. The coupling nut improves grip during tightening and helps technicians secure the connector correctly.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #1565c0;\"\u003e\u003cstrong\u003e200152-04-10\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct category:\u003c\/strong\u003e Accelerometer interface cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 4.0 meters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector configuration:\u003c\/strong\u003e Connector on the accelerometer end only, according to the supplied ordering description\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Connect compatible accelerometers to vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown | Decode Each Suffix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration element\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003cth\u003eEngineering relevance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003e200152\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReferenced cable model number\u003c\/td\u003e\n\u003ctd\u003eConfirm the complete part number against the applicable Bently Nevada catalog.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003e-04\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0-meter cable length\u003c\/td\u003e\n\u003ctd\u003eProvides the specified cable reach between the sensor and the connection point.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003e-10\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnhanced coupling nut\u003c\/td\u003e\n\u003ctd\u003eImproves tightening grip at the accelerometer end only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering verification:\u003c\/strong\u003e The supplied description identifies the ordering model as 200151 but labels the minimum bend radius as 200152. Confirm the exact base model and configuration before ordering a replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical and Mechanical Construction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eProvided information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor arrangement\u003c\/td\u003e\n\u003ctd\u003e4 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd\u003e22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eBraided shield with drain wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield coverage\u003c\/td\u003e\n\u003ctd\u003eMinimum 85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter jacket\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling nut material\u003c\/td\u003e\n\u003ctd\u003eNickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector construction\u003c\/td\u003e\n\u003ctd\u003eMolded to the cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector sealing\u003c\/td\u003e\n\u003ctd\u003eIP67 seal with compatible transducers and mating hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum bend radius\u003c\/td\u003e\n\u003ctd\u003e73.7 mm (2.9 in), specified in the supplied information for model 200152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable operating temperature\u003c\/td\u003e\n\u003ctd\u003e−20°C to +100°C (−4°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Protection and Installation Limits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture protection:\u003c\/strong\u003e The connector provides an IP67 seal when correctly mated with compatible hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal shock protection:\u003c\/strong\u003e DC4 electrical insulating compound inside the connectors provides additional moisture protection during thermal shock.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-weather handling:\u003c\/strong\u003e Lower temperatures may be acceptable when the installation prevents cable flexing or bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-temperature caution:\u003c\/strong\u003e Flexing the cable below −20°C may damage its construction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend control:\u003c\/strong\u003e Maintain the specified minimum bend radius to reduce conductor and jacket stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompound specification note:\u003c\/strong\u003e The supplied information also lists a temperature range of −55°C to +121°C and a 24-hour cure time. Confirm the exact material and application associated with these values before using them in installation procedures. Do not treat them as the cable's operating temperature rating.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidance for Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the interface.\u003c\/strong\u003e Check the accelerometer model, mating connector, and monitoring system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the cable route.\u003c\/strong\u003e Allow sufficient length for service access without creating excessive slack or tight loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the bend radius.\u003c\/strong\u003e Keep bends at or above 73.7 mm where this specification applies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the connector.\u003c\/strong\u003e Use the enhanced coupling nut on the accelerometer end and follow the manufacturer's tightening instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the cable path.\u003c\/strong\u003e Avoid sharp edges, crushing points, hot surfaces, and moving machine parts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManage electrical interference.\u003c\/strong\u003e Route the cable away from high-current conductors where practical and follow the system's grounding requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect before startup.\u003c\/strong\u003e Check the jacket, connector seating, mating surfaces, and cable strain relief.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe cable suits vibration monitoring installations that use compatible accelerometers and matching Bently Nevada interface hardware. Verify the exact sensor and monitor combination before installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotating machinery:\u003c\/strong\u003e Connect compatible accelerometers used to monitor motors, pumps, and fans.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial compressors:\u003c\/strong\u003e Support vibration signal connections where the installed accelerometer and monitoring channel accept this cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGearboxes:\u003c\/strong\u003e Maintain sensor connections for condition monitoring and vibration trend collection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess equipment:\u003c\/strong\u003e Support vibration monitoring on compatible equipment in continuous production environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance programs:\u003c\/strong\u003e Replace damaged or incorrectly routed sensor cables during planned maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition monitoring systems:\u003c\/strong\u003e Carry sensor signals to compatible monitoring hardware for analysis and trending.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostic Value and Field Troubleshooting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis cable provides the physical signal path between a compatible accelerometer and monitoring equipment. It does not independently analyze vibration or diagnose machine faults.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eObserved symptom\u003c\/th\u003e\n\u003cth\u003ePossible cable-related cause\u003c\/th\u003e\n\u003cth\u003eRecommended check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo vibration signal\u003c\/td\u003e\n\u003ctd\u003eLoose connector, damaged conductor, or incompatible interface\u003c\/td\u003e\n\u003ctd\u003eInspect both connection points and verify the approved wiring configuration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent readings\u003c\/td\u003e\n\u003ctd\u003eConnector movement, cable strain, or internal conductor damage\u003c\/td\u003e\n\u003ctd\u003eInspect the cable route and test continuity using an approved procedure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected signal noise\u003c\/td\u003e\n\u003ctd\u003eShield damage, grounding issues, or interference from nearby power wiring\u003c\/td\u003e\n\u003ctd\u003eInspect shield continuity and cable separation from electrical noise sources.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoisture-related faults\u003c\/td\u003e\n\u003ctd\u003eIncorrect mating, damaged sealing surfaces, or connector contamination\u003c\/td\u003e\n\u003ctd\u003eInspect connector condition and verify proper mating with compatible hardware.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeated cable failures\u003c\/td\u003e\n\u003ctd\u003eExcessive bending, vibration-induced movement, or mechanical abrasion\u003c\/td\u003e\n\u003ctd\u003eReview routing, bend radius, support points, and environmental exposure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eField technicians should inspect cable routing and connector condition before replacing an accelerometer or monitoring channel. Cable faults can imitate sensor or signal-conditioning problems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField example:\u003c\/strong\u003e A pump monitoring channel may show intermittent vibration readings after maintenance. If the readings change when technicians inspect the connector area, check coupling security, cable strain, and shield continuity before replacing the sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSelection insight:\u003c\/strong\u003e Choose the cable length from the actual installation route rather than the straight-line distance. Allow service access while avoiding unnecessary loops near rotating machinery or hot surfaces.\u003c\/p\u003e\n\u003cp\u003eThese checks provide practical fault-isolation guidance. Confirm any suspected electrical defect with the applicable equipment manual and approved test procedure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFive Professional FAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the enhanced coupling nut improve maintenance work?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe enhanced nut provides a better grip when tightening the connector at the accelerometer end. Follow the manufacturer's specified tightening method and avoid excessive force.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can technicians install this cable in a continuously moving cable carrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDo not assume suitability for continuous flexing. The supplied specifications warn against flexing below −20°C and do not establish a continuous-flex rating. Confirm the application with the manufacturer before using a moving cable carrier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What should buyers check when a replacement cable looks identical to the original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompare the complete part number, cable length, connector arrangement, coupling nut option, and mating interface. Similar appearance does not guarantee identical electrical or mechanical compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does an IP67 connector rating guarantee protection in every installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The stated seal applies to compatible transducers and mating hardware. Damaged seals, incorrect mating, contamination, or unsuitable installation conditions can compromise protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How can maintenance teams determine whether a cable or accelerometer causes an unstable reading?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInspect connectors, routing, and shielding first. Then follow the site's approved diagnostic procedure to test cable continuity and compare readings using known-good compatible components. Never disconnect monitoring hardware on operating machinery without the required safety authorization.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging, Warranty and Shipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Bently Nevada accelerometer interface cable in the confirmed ordered configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessories:\u003c\/strong\u003e Additional connectors, sensors, and installation hardware require separate confirmation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month warranty under the seller's agreed terms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch:\u003c\/strong\u003e Target dispatch within 24–48 hours after order confirmation, subject to stock verification and payment processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCourier options:\u003c\/strong\u003e FedEx, UPS, and DHL, subject to destination and service availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e Confirm the full model number, required length, connector interface, delivery address, and shipping schedule.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRequest Pricing and Compatibility Confirmation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eContact \u003cstrong\u003eGlobal PLC Spare HUB\u003c\/strong\u003e for a quotation on the \u003cstrong\u003e\u003cspan style=\"color: #1565c0;\"\u003eBently Nevada 200152-04-10\u003c\/span\u003e\u003c\/strong\u003e accelerometer interface cable.\u003c\/p\u003e\n\u003cp\u003eProvide your accelerometer model, monitoring equipment model, required quantity, and delivery destination. Our team can help review the configuration and confirm availability before order placement.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/200152_2.png?v=1790235039\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":67644031074486,"sku":"200152-04-10","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada200152_10.jpg?v=1792036691","url":"https:\/\/www.plcsparehub.com\/products\/200152-04-10-bently-nevada-standard-interface-cable-for-vibration-systems","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}