{"product_id":"200151-xx-xx-xx-bently-nevada-accelerometer-interface-standard-cable","title":"200151-XX-XX-XX Bently Nevada Accelerometer Interface Standard Cable","description":"\u003ch3\u003e\u003cb\u003eProduct Overview\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 200151-XX-XX-XX (part number \u003cstrong style=\"color: #0056b3;\"\u003e323357-15-03-00\u003c\/strong\u003e) is a heavy-duty Accelerometer Interface Standard Cable designed by \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e for industrial vibration monitoring systems. Featuring factory-molded connectors on both ends, this assembly provides secure, low-noise signal transmission between acceleration transducers and monitoring hardware in severe operating environments.\u003c\/p\u003e\n\u003cp\u003eConstructed with a 4-conductor 22 AWG wiring arrangement, a minimum 85% coverage braided shield, and a dedicated drain wire, the \u003cstrong style=\"color: #0056b3;\"\u003e200151\u003c\/strong\u003e prevents electromagnetic interference (EMI) and radio frequency interference (RFI) from corrupting dynamic signal lines. The molded connectors deliver IP67 ingress protection, ensuring water-tight reliability even during thermal shock conditions when treated with DC4 electrical insulating compound.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCable Construction \u0026amp; Technical Attributes\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eConductor Architecture \u0026amp; Shielding\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFour 22 AWG stranded conductors engineered for low-capacitance dynamic signal transfer.\u003c\/li\u003e\n\u003cli\u003eTinned copper braided shield delivering a minimum of 85% coverage to isolate low-amplitude AC signal frequencies.\u003c\/li\u003e\n\u003cli\u003eIntegrated drain wire for continuous electrostatic charge dissipation and grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental Sealing \u0026amp; Jacket Specifications\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible oil-resistant and chemical-resistant PVC outer jacket.\u003c\/li\u003e\n\u003cli\u003eFactory-molded IP67-rated connector boot providing sealed strain relief against moisture ingress.\u003c\/li\u003e\n\u003cli\u003eNickel-plated coupling nuts resistant to corrosive industrial atmospheres.\u003c\/li\u003e\n\u003cli\u003eDC4 electrical insulating compound integration inside connectors for thermal shock moisture protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOrdering Option Structure (200151-AA-BB-CC)\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOption A (XX):\u003c\/b\u003e Defines custom Cable Length parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOption B (XX):\u003c\/b\u003e Specifies stainless steel or flexible Armor Options for mechanical protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOption C (XX):\u003c\/b\u003e Selects specialized Coupling Nut threads and material configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePart Number\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong style=\"color: #0056b3;\"\u003e200151-XX-XX-XX\u003c\/strong\u003e (Model 323357-15-03-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eManufacturer \u0026amp; Brand\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eProduct Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAccelerometer Interface Standard Cable Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eConnector Configuration\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory-Molded Connectors on Both Ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eInternal Conductors\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Conductor, 22 AWG Stranded Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eShielding Performance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned Copper Braided Shield (≥85% Coverage) with Drain Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOuter Jacket Material\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-Flex Industrial Polyvinyl Chloride (PVC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCoupling Nut Hardware\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-Duty Nickel-Plated Metallic Nuts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIngress Protection Rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 Sealed (Dust-Tight \u0026amp; Submersion Resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDynamic Flexing Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +100°C (-4°F to +212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eStatic \/ Lower Storage Limit\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-55°C to +121°C (-67°F to +250°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMinimum Bend Radius\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e63.5 mm (2.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePotting Compound Cure Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Hours (Fully Cured Interface Assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eDiagnostic Capabilities \u0026amp; Signal Integrity Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003ePhase Loss \u0026amp; Ground Loop Isolation:\u003c\/b\u003e High-density braided shielding prevents stray ground current loops from corrupting high-frequency FFT spectra.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThermal Shock Resistance:\u003c\/b\u003e Internal DC4 compound prevents internal condensation during rapid ambient temperature shifts, avoiding spurious bias voltage shifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStrain Relief Visual Inspection:\u003c\/b\u003e Molded boot strain reliefs allow field engineers to quickly verify mechanical tension fatigue and prevent internal conductor breaks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTarget Application Scenarios \u0026amp; Monitoring Equipment\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eRotating Machinery Protection:\u003c\/b\u003e Transmits high-frequency vibration signals from casing accelerometers on gas turbines, high-speed gearboxes, and boiler feed pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBently Nevada 3500 System Integration:\u003c\/b\u003e Connects acceleration sensors directly to 3500\/42M or 3500\/40M monitor channels without signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSevere Outdoor Environments:\u003c\/b\u003e Used in offshore oil platforms, cooling towers, and petrochemical units where exposure to washdown and moisture is continuous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation \u0026amp; Cable Routing Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eObserve Minimum Bend Radius:\u003c\/b\u003e Never route the assembly tighter than the 63.5 mm (2.5 in) bend radius threshold to avoid damaging internal shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow-Temperature Handling Warning:\u003c\/b\u003e Avoid flexing or pulling cables at temperatures below -20°C (-4°F), as cold PVC jackets become brittle and risk cracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCoupling Torque \u0026amp; Compound Application:\u003c\/b\u003e Ensure coupling nuts are hand-tightened and apply DC4 compound when mating in high-humidity zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackaging, Logistics \u0026amp; Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDispatch Lead Time:\u003c\/b\u003e In-stock inventory processed and prepared for dispatch within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress Global Carriers:\u003c\/b\u003e Priority international transport via DHL Express, FedEx, and UPS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOriginal Packaging:\u003c\/b\u003e Delivered 100% Brand New and Original in sealed factory packaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e12-Month Coverage:\u003c\/b\u003e Covered by a full 12-month quality replacement warranty against manufacturing defects.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eEngineering Procurement Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eVerify Armor Requirements:\u003c\/b\u003e Specify Option B (Armor) for runs through exposed cable trays where falling debris or foot traffic could crush bare PVC jackets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCheck Total Cable Distance:\u003c\/b\u003e Verify line capacitance across extended lengths to confirm dynamic vibration high-frequency response remains unattenuated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMatch Sensor Interface:\u003c\/b\u003e Confirm the coupling nut thread type matches the target accelerometer header style before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eQ: What happens if this cable assembly is flexed in freezing environments below -20°C?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Bending the assembly below -20°C causes mechanical stress that can fracture the hardened outer PVC jacket and break internal 22 AWG strands.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Is the DC4 electrical insulating compound pre-applied inside the connector boots?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, DC4 compound is applied during factory assembly to fill micro-voids, providing an IP67 barrier against thermal shock condensation.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Can I trim this molded assembly in the field to adjust length?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: Trimming removes the factory-molded IP67 connector; for custom lengths, always select the exact AA length option when placing orders.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Why is an 85% minimum braided shield coverage required for accelerometer runs?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: High-coverage braiding blocks ambient high-frequency EMI generated by nearby variable frequency drives (VFDs) from entering the signal path.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eQ: Does this cable assembly require external conduit when installed outdoors?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eA: While the PVC jacket resists weather and moisture, selecting Option B stainless steel armor provides essential protection against UV radiation and physical crushing.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eGlobal PLC Spare HUB's Insight\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eA petrochemical processing plant experienced persistent high-frequency noise spikes on their induced draft fan vibration channels, triggering false alarms on their 3500 rack system. Field technicians had used generic non-shielded cabling during a quick turnaround, exposing the millivolt accelerometer outputs to neighboring motor drive interference.\u003c\/p\u003e\n\u003cp\u003eOur technical team supplied factory-original \u003cstrong style=\"color: #0056b3;\"\u003e200151\u003c\/strong\u003e armored cable assemblies featuring 85% braided shielding and IP67 molded boots. Once installed, the high-frequency floor noise dropped instantly by over 90%, eliminating false trips and securing stable, long-term vibration monitoring across the entire compressor deck.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/200151.png?v=1789019192\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45435131199670,"sku":"323357-15-03-00","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/Bently21505_16.jpg?v=1789019342","url":"https:\/\/www.plcsparehub.com\/products\/200151-xx-xx-xx-bently-nevada-accelerometer-interface-standard-cable","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}