{"product_id":"200150-12-05-bently-nevada-trendmaster-2000-accelerometer","title":"200150-12-05 Bently Nevada Trendmaster 2000 Accelerometer","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: Global PLC Spare HUB delivers mission-critical industrial sensing hardware for continuous machinery health logging. The \u003cb style=\"color: #0056b3;\"\u003e200150-12-05\u003c\/b\u003e belongs to the \u003cb style=\"color: #0056b3;\"\u003eTrendmaster 2000\u003c\/b\u003e series. Reliability engineers deploy this shear-mode ceramic accelerometer within harsh plant floors to monitor high-frequency casing vibrations on continuous-duty rotating assets.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cb style=\"color: #0056b3;\"\u003e200150\u003c\/b\u003e - General Purpose Trendmaster 2000 Accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Stud Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 = 3\/8-24 to 1\/4-20 UNC, 3\/4 inch hex stud adapter configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 = Multiple hazardous area certifications including CSA, ATEX, and IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb style=\"color: #0056b3;\"\u003eBently Nevada\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb style=\"color: #0056b3;\"\u003e200150-12-05\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.2 mV\/(m\/s2) or 100 mV\/g nominal output at 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlus or minus 245 m\/s2 pk (plus or minus 25 g pk) acceleration span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1000 Hz (600 to 60,000 cpm) referenced to 80 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreater than 20 kHz (greater than 1200 kcpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlus or minus 2% across 1 to 10g peak range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation and Bias\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7 to 5.5 Vdc supply voltage with +2.5 Vdc output bias\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +105°C housing operational limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCasing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid 316L stainless steel housing for extreme corrosion resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClean the machinery mounting spot thoroughly to ensure flat, metal-to-metal contact.\u003c\/li\u003e\n\u003cli\u003eApply a thin layer of coupling fluid to the mating surface to optimize high-frequency transmission.\u003c\/li\u003e\n\u003cli\u003eThread the 3\/8-24 stud into the pre-drilled and tapped machinery pad.\u003c\/li\u003e\n\u003cli\u003eTighten the hardware using a calibrated torque wrench between 2.7 and 6.8 N-m (2 to 5 ft-lbf).\u003c\/li\u003e\n\u003cli\u003eRoute the low-noise twisted triad cable away from high-voltage power conduits to prevent electromagnetic induction.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommissioning and Maintenance Convenience\u003c\/h3\u003e\n\u003cp\u003eThe unit settles within 300 milliseconds of power application, allowing rapid loop verification during startup. Quiescent current remains below 800 microamps, minimizing thermal self-heating inside the internal electronics. Technicians can verify circuit health instantly by measuring the static output bias voltage against the 2.5 Vdc baseline reference.\u003c\/p\u003e\n\u003ch3\u003eCompatibility Notes\u003c\/h3\u003e\n\u003cp\u003eThis transducer interfaces directly with ProTIM modules configured for standard acceleration-to-velocity channel types (-01). Ensure the monitoring system power supply provides a regulated constant current source within the specified 4.7 to 5.5 Vdc excitation envelope.\u003c\/p\u003e\n\u003ch3\u003eCertification Information\u003c\/h3\u003e\n\u003cp\u003eThe assembly carries multiple global explosion-proof ratings. Certified classifications include CSA, ATEX, and IECEx directives for safe operation in explosive gas and dust atmospheres.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents and Warranty\u003c\/h3\u003e\n\u003cp\u003eEach delivery box contains one factory-tested \u003cb style=\"color: #0056b3;\"\u003e200150-12-05\u003c\/b\u003e vibration transducer along with its specified mounting stud. Global PLC Spare HUB backs this industrial item with a solid 12-month replacement warranty.\u003c\/p\u003e\n\u003ch3\u003eLogistics and Delivery\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB processes and ships orders within 24 to 48 hours. Expedited international delivery runs via trusted couriers including FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003eTypical Application Scenarios and Diagnostic Capability\u003c\/h3\u003e\n\u003cp\u003eIndustrial plants deploy this sensor on heavy centrifugal pumps, industrial fans, electric motors, gearboxes, and large air compressors. The shear-mode ceramic element captures high-frequency impact energy, enabling early detection of gear tooth pitting, rolling element bearing degradation, cavitation, and structural looseness before catastrophic failure occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the shear-mode ceramic element inside this housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eShear geometry isolates the sensing crystal from base-bending strains and thermal transients, ensuring that measured signals reflect true machine vibration rather than structural distortion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does my reading drift immediately after torquing the sensor down?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOver-tightening beyond 6.8 N-m can distort the mounting base or stress the internal piezoelectric crystal, causing temporary offset voltage shifts or baseline instability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I paint over the 316L stainless steel body to match my machine color?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePainting the housing is strongly discouraged because it insulates the body from ambient air, trapping heat and potentially driving internal electronics past their thermal limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I test if the transducer is shorted before connecting it to the ProTIM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMeasure the resistance between the signal pin and the outer stainless steel case using a digital multimeter; a healthy unit should show an open circuit rather than zero ohms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat criteria should guide my selection when choosing between different Trendmaster studs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMatch your machine pad's existing thread depth and diameter to the stud conversion kit, ensuring maximum thread engagement without bottoming out the stud base.\u003c\/p\u003e\n\u003ch3\u003eBuying Guide\u003c\/h3\u003e\n\u003cp\u003eWhen selecting industrial accelerometers, evaluate your machinery's operating frequency spectrum, environmental exposure hazards, and monitoring system input power compatibility. Procuring exact factory part numbers like the \u003cb style=\"color: #0056b3;\"\u003e200150-12-05\u003c\/b\u003e guarantees full calibration compliance and seamless integration with existing distributed diagnostic networks.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/200150.png?v=1784606920\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013980774582,"sku":"200150-12-05","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/BentlyNevada200150_14.jpg?v=1784606935","url":"https:\/\/www.plcsparehub.com\/products\/200150-12-05-bently-nevada-trendmaster-2000-accelerometer","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}