{"product_id":"190501-12-99-00-bently-nevada-velocity-sensor-for-machinery-monitoring","title":"190501-12-99-00 Bently Nevada Velocity Sensor for Machinery Monitoring","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501-12-99-00\u003c\/span\u003e Bently Nevada Velomitor CT Velocity Transducer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501-12-99-00\u003c\/span\u003e\u003c\/strong\u003e is an industrial velocity transducer designed for continuous machinery vibration monitoring.\u003c\/p\u003e\n\u003cp\u003eThe sensor belongs to the trusted \u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003eBently Nevada Velomitor CT\u003c\/span\u003e\u003c\/strong\u003e monitoring family.\u003c\/p\u003e\n\u003cp\u003eThe transducer converts vibration velocity into stable electrical output signals.\u003c\/p\u003e\n\u003cp\u003eEngineers deploy this sensor in rotating equipment protection and predictive maintenance systems.\u003c\/p\u003e\n\u003cp\u003eThe design combines wide frequency response, high environmental durability, and stable output performance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConfiguration Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Structure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVelomitor CT Velocity Transducer Base Model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate Stud 3\/8-in 24 to M8x1 Mounting Hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e99\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnit with Included 32-foot Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Version Without Additional Agency Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Performance Profile\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501-12-99-00\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003eVelomitor CT Velocity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e3.94 mV\/mm\/s ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e3 Hz to 900 Hz ±1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eExtended Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e1.5 Hz to 1 kHz ±3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eAmplitude Linearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e±2% to 63.5 mm\/s peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eTransverse Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003eLess than 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Bias Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e10.1 VDC ±1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eDynamic Output Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003eBelow 400 Ω typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e9 kHz minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eBroadband Noise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e0.229 mm\/s peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.9222%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 49.2104%; height: 19.5938px;\"\u003e305 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +100°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 5000 g peak maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Resistance:\u003c\/strong\u003e 100% condensing tolerance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic Field Susceptibility:\u003c\/strong\u003e Less than 0.0068 mm\/s\/gauss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e 316L stainless steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e 2-pin MIL-C5015 connector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Surface Diameter:\u003c\/strong\u003e 33 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Height:\u003c\/strong\u003e 82 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Torque:\u003c\/strong\u003e 4.5 N-m ±0.6 N-m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Orientation:\u003c\/strong\u003e Any mounting angle supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.297 kg typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Integrity and Diagnostic Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides stable vibration velocity output under dynamic load conditions\u003c\/li\u003e\n\u003cli\u003eSupports continuous rotating machinery health monitoring\u003c\/li\u003e\n\u003cli\u003eMaintains signal integrity over long cable distances\u003c\/li\u003e\n\u003cli\u003eDetects abnormal vibration growth in critical assets\u003c\/li\u003e\n\u003cli\u003eImproves predictive maintenance efficiency\u003c\/li\u003e\n\u003cli\u003eSupports trend analysis within machinery protection systems\u003c\/li\u003e\n\u003cli\u003eReduces false alarms through controlled transverse sensitivity\u003c\/li\u003e\n\u003cli\u003eSupports high-noise industrial environments effectively\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSuitable Equipment and Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine monitoring systems\u003c\/li\u003e\n\u003cli\u003eGas turbine vibration protection\u003c\/li\u003e\n\u003cli\u003eIndustrial compressor monitoring\u003c\/li\u003e\n\u003cli\u003eLarge rotating motor diagnostics\u003c\/li\u003e\n\u003cli\u003ePump vibration analysis systems\u003c\/li\u003e\n\u003cli\u003eCooling tower fan monitoring\u003c\/li\u003e\n\u003cli\u003ePower generation equipment\u003c\/li\u003e\n\u003cli\u003ePetrochemical rotating machinery\u003c\/li\u003e\n\u003cli\u003eMining process equipment monitoring\u003c\/li\u003e\n\u003cli\u003eCondition-based maintenance systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eIntrinsic Safety and Hazardous Area Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501\u003c\/span\u003e\u003c\/strong\u003e series supports intrinsically safe installation configurations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Ex ia IIC T4 hazardous area applications\u003c\/li\u003e\n\u003cli\u003eSupports Class I Division 1 installation environments\u003c\/li\u003e\n\u003cli\u003eSupports Class II Groups E, F, and G areas\u003c\/li\u003e\n\u003cli\u003eSupports non-incendive industrial installation requirements\u003c\/li\u003e\n\u003cli\u003eSupports hazardous area machinery monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eGlobal PLC Spare HUB's Insight\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #c00000;\"\u003e190501-12-99-00\u003c\/span\u003e\u003c\/strong\u003e performs reliably in high-vibration industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe sensor maintains stable output during long-term continuous machinery operation.\u003c\/p\u003e\n\u003cp\u003eIts stainless steel housing improves durability in corrosive industrial locations.\u003c\/p\u003e\n\u003cp\u003eThe extended frequency response supports accurate low-speed and high-speed machine monitoring.\u003c\/p\u003e\n\u003cp\u003eField engineers often select this model for turbine and compressor protection systems.\u003c\/p\u003e\n\u003cp\u003eThe transducer integrates efficiently with industrial vibration monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Field Deployment Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall on rigid mounting surfaces for accurate vibration transfer\u003c\/li\u003e\n\u003cli\u003eUse specified mounting torque during installation\u003c\/li\u003e\n\u003cli\u003eSeparate sensor cable from high-voltage wiring paths\u003c\/li\u003e\n\u003cli\u003eVerify polarity before system commissioning\u003c\/li\u003e\n\u003cli\u003eUse shielded routing practices in high EMI environments\u003c\/li\u003e\n\u003cli\u003eInspect connector sealing during outdoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePackaging and Shipping Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional anti-static packaging included\u003c\/li\u003e\n\u003cli\u003eIndustrial protective packing applied before shipment\u003c\/li\u003e\n\u003cli\u003eFedEx international shipping available\u003c\/li\u003e\n\u003cli\u003eUPS priority logistics support available\u003c\/li\u003e\n\u003cli\u003eDHL express delivery available worldwide\u003c\/li\u003e\n\u003cli\u003eMost orders dispatch within 24–48 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty and Service Commitment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eTechnical support available after delivery\u003c\/li\u003e\n\u003cli\u003ePre-shipment inspection completed before dispatch\u003c\/li\u003e\n\u003cli\u003eIndustrial export packaging standard applied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProfessional FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhy is low transverse response important in vibration monitoring?\u003c\/strong\u003e\n\u003cp\u003eLow transverse sensitivity improves measurement accuracy during multi-axis machine vibration conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhen should engineers select a velocity transducer instead of an accelerometer?\u003c\/strong\u003e\n\u003cp\u003eVelocity transducers suit rotating equipment requiring overall vibration severity monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does stainless steel housing benefit field applications?\u003c\/strong\u003e\n\u003cp\u003e316L stainless steel improves corrosion resistance in harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat installation practice improves signal reliability most effectively?\u003c\/strong\u003e\n\u003cp\u003eUse rigid mounting surfaces and separate sensor cables from power wiring routes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat should buyers verify before selecting \u003cspan style=\"color: #c00000;\"\u003e190501-12-99-00\u003c\/span\u003e?\u003c\/strong\u003e\n\u003cp\u003eConfirm mounting thread compatibility, monitoring frequency range, cable distance, and hazardous area requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/190501_Graphs_and_Figures.png?v=1777450901\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45013814182070,"sku":"190501-12-99-00","price":170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/190501_1_e098651a-e950-444e-897d-5830bb0a27de.jpg?v=1779788846","url":"https:\/\/www.plcsparehub.com\/products\/190501-12-99-00-bently-nevada-velocity-sensor-for-machinery-monitoring","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}