{"product_id":"1797-ps1e-allen-bradley-1797-flex-i-o-ex-power-supply","title":"1797-PS1E Allen-Bradley 1797 FLEX I\/O Ex Power Supply","description":"\u003ch3\u003e\u003cb\u003eAllen-Bradley 1797-PS1E – FLEX Ex Power Supply\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1797-PS1E\u003c\/strong\u003e is an AC-powered supply module in the \u003cstrong\u003eFLEX I\/O 1797 FLEX Ex\u003c\/strong\u003e product family. It converts a wide-range AC input into four DC output channels for compatible intrinsically safe field-device circuits.\u003c\/p\u003e\n\u003cp\u003eDesigned for hazardous-area automation installations, the module combines galvanically isolated outputs, independent intrinsic-safety current limitation and an IP65-rated enclosure. Its increased-safety input and output terminations support field wiring in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eUnlike a conventional control-cabinet power supply, the 1797-PS1E must be evaluated as part of the complete hazardous-area installation. Output circuit classification, wiring practices, grounding and environmental conditions all affect whether the installation remains suitable for its intended area.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003ePower Distribution Profile\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85–253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e55 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.9 A (as specified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e9.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power Rating\u003c\/td\u003e\n\u003ctd\u003e8.5 W per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Rated Output Power\u003c\/td\u003e\n\u003ctd\u003e34 W, based on four 8.5 W channel ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminals 10–17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminals 1, 2, 4 and 5 (including protective earth connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eFour-Channel Output Architecture\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides four independently intrinsically safe-limited output channels. Each channel has an individual output power rating of 8.5 W, allowing power distribution to compatible field circuits.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour output channels:\u003c\/strong\u003e Provides separate power connections for supported field loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic isolation:\u003c\/strong\u003e Output power is galvanically isolated from the source, according to the supplied specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent IS limitation:\u003c\/strong\u003e Each output is independently limited for intrinsic-safety applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage:\u003c\/strong\u003e 9.5 V DC nominal, as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal arrangement:\u003c\/strong\u003e Output connections use terminals 10 through 17.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The 8.5 W rating applies to each output channel. Actual usable load capacity must also account for the equipment connected to each circuit and the applicable installation requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eHazardous-Area Construction and Wiring\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eConstruction Detail\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cable Gland\u003c\/td\u003e\n\u003ctd\u003eM20 × 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e6–12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Gland\u003c\/td\u003e\n\u003ctd\u003eM16 × 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e4–8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Termination\u003c\/td\u003e\n\u003ctd\u003eIncreased-safety connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Termination\u003c\/td\u003e\n\u003ctd\u003eIncreased-safety connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation from source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe sealed cable entries provide defined cable-diameter ranges for input and output wiring. Correct gland selection and cable installation are essential to maintaining the enclosure's specified protection level.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Environment and Area Classification\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous-Area Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZone 1 and Zone 22, subject to applicable certification and installation conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZone 22 Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCategory 3D, as stated in the supplied product information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Permitted Voltage, Um\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e253 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor operation at an ambient temperature of 60°C, the supplied installation information specifies power supply leads rated for an 80°C service temperature.\u003c\/p\u003e\n\u003cp\u003eHazardous-area suitability must be confirmed against the product nameplate, applicable certificates and the current installation standards. The area classification alone does not establish approval for every installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eMechanical and Electrical Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFLEX I\/O 1797\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFLEX Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1797-PS1E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Input \/ Quad Ex DC Output Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71.67 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSee verification note below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e612598182961\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.51 × 6.9 × 11.0 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cb\u003eField Installation: Points That Matter\u003c\/b\u003e\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting and bonding:\u003c\/strong\u003e Use suitable mounting hardware. Star washers and nuts are recommended in the supplied installation guidance to establish reliable electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding surface:\u003c\/strong\u003e Where grounding bolts are used, remove paint or coating from the designated sub-panel contact area to maintain electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput wiring:\u003c\/strong\u003e Connect the AC supply to the specified input terminals and observe the maximum permitted voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput wiring:\u003c\/strong\u003e Route the four output circuits through the specified cable entries. Follow the approved terminal arrangement and intrinsic-safety wiring rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFerrite installation:\u003c\/strong\u003e The supplied guidance recommends routing power supply output wires through the ferrite bead before connecting them to the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD protection:\u003c\/strong\u003e Protect the device against electrostatic discharge during handling and maintenance. Use suitable ESD precautions and identification signage where required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature verification:\u003c\/strong\u003e Check the actual ambient temperature and select wiring with the required temperature rating.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003e\u003cb\u003eDaisy-Chain Power Planning\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information identifies daisy-chain connection as an available arrangement when the total module power draw remains below 8.5 W. If the load exceeds this stated condition, individual power supplies are recommended.\u003c\/p\u003e\n\u003cp\u003eBefore designing a daisy-chain arrangement, verify the applicable Rockwell Automation wiring diagram and power-budget rules. Do not interpret the 8.5 W per-output rating as permission to exceed the documented supply or circuit limits.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplication Areas\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFLEX Ex distributed I\/O installations\u003c\/li\u003e\n\u003cli\u003eHazardous-area field-device power distribution\u003c\/li\u003e\n\u003cli\u003eIndustrial process monitoring and control systems\u003c\/li\u003e\n\u003cli\u003eZone 1 and Zone 22 applications where the installed equipment and certification permit\u003c\/li\u003e\n\u003cli\u003eSystems requiring galvanically isolated, intrinsically safe output circuits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":68113044308150,"sku":"1797-PS1E","price":321.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1797-PS1E-1.jpg?v=1795162136","url":"https:\/\/www.plcsparehub.com\/products\/1797-ps1e-allen-bradley-1797-flex-i-o-ex-power-supply","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}