{"product_id":"1769-ow16-allen-bradley-compactlogix-discrete-output-module","title":"1769-OW16 Allen-Bradley CompactLogix Discrete Output Module","description":"\u003ch3\u003e1769-OW16 Allen-Bradley CompactLogix Discrete Output Module | 1769-OW16 Relay Unit\u003c\/h3\u003e\n\u003cp\u003eGlobal PLC Spare HUB's Insight: The \u003cstrong\u003e1769-OW16\u003c\/strong\u003e module delivers reliable switching performance for multi-voltage industrial control panels. Field engineers appreciate the dual-group isolation architecture, which permits simultaneous management of different potential levels safely. By integrating this discrete output unit into legacy CompactLogix or MicroLogix 1500 assemblies, automation professionals extend system lifespan and optimize local load handling without major architecture overhauls.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter Classification\u003c\/th\u003e\n\u003cth\u003eOperational Metric\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAllen-Bradley\u003c\/strong\u003e \/ \u003cstrong\u003eRockwell Automation\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line \u0026amp; Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.plcsparehub.com\/collections\/allen-bradley-1769-compactlogix\"\u003e\u003cstrong\u003eCompactLogix\u003c\/strong\u003e\u003c\/a\u003e \/ \u003cstrong\u003eCompact I\/O\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1769-OW16\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete Output Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAC\/DC Normally Open Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 Channels (2 Isolated Groups of 8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Span\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 to 265 VAC or 5 to 125 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.5 A per Point, 20 A per Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Response Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 ms Maximum (On and Off States)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 mA at 5.1V DC, 100 mA at 24V DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePermissible Wire Gauges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e22 to 14 AWG Solid \/ 22 to 16 AWG Stranded\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4.75 Watts Maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Deployment and Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Positioning:\u003c\/strong\u003e Mount the unit directly onto a standard DIN rail or secure panel, ensuring a maximum distance of eight modules away from the system power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection:\u003c\/strong\u003e Lock the integral slide-style bus levers firmly into adjacent modules to maintain secure electronic backplane communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Strip copper-90 wire correctly and insert conductors into screw terminals, torquing properly to withstand 2G operational vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and System Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe module architecture incorporates internal status data registers that log operational states and communication errors. System integrators read these status files via programming software to pinpoint stuck relay contacts or address configuration mismatches instantly. Furthermore, verifying controller fault tables helps isolate abnormal voltage spikes or thermal overloads across individual output groups.\u003c\/p\u003e\n\u003ch3\u003eTarget Applications and System Compatibility\u003c\/h3\u003e\n\u003cp\u003eEngineers deploy this hardware extensively within distributed factory automation systems, HVAC distribution panels, and material handling conveyor logics. The unit interfaces seamlessly with CompactLogix controllers, MicroLogix 1500 controller expansions, and 1769-AENTR Ethernet or DeviceNet adapter assemblies.\u003c\/p\u003e\n\u003ch3\u003eFulfillment, Shipping, and Warranty Terms\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispatch Window:\u003c\/strong\u003e Orders process and dispatch securely within 24 to 48 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogistics Partners:\u003c\/strong\u003e Expedited worldwide transport via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Fully backed by a 12-month replacement warranty from Global PLC Spare HUB.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e How can technicians verify if an isolated group on the \u003cstrong\u003e1769-OW16\u003c\/strong\u003e is receiving proper bus power?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Engineers check the internal processor data files using programming software to confirm that backplane voltage parameters and slot communication bits reflect active status without faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What precautions prevent premature contact wear when driving inductive loads with this module?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Field technicians should install appropriate external surge suppressors, such as RC networks or diodes, across inductive loads to absorb high-voltage kickbacks during the break state.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Why does the system signal a power supply distance fault after adding this unit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e The module sits beyond the 8-module power supply distance rating limit, requiring the insertion of an additional system power supply or a modular bus spacer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e Can mixed AC and DC load voltages run simultaneously through different groups of the same unit?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Yes, because the two groups of eight channels are physically isolated, allowing distinct voltage categories to operate safely side by side.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuestion:\u003c\/strong\u003e What selection factors guide engineers when choosing between solid-state and this relay output version?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnswer:\u003c\/strong\u003e Selection depends on switching frequency and load type; choose this relay version for high-voltage tolerance, multi-voltage flexibility, and robust mechanical isolation rather than high-speed cycling.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45013913141430,"sku":"1769-OW16","price":179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0722\/7863\/8774\/files\/1769-OW16_564f7354-23ec-4b28-8605-3402270add06.jpg?v=1784701851","url":"https:\/\/www.plcsparehub.com\/products\/1769-ow16-allen-bradley-compactlogix-discrete-output-module","provider":"Global PLC Spare Hub","version":"1.0","type":"link"}